
Siemens 6AV6381-2BN08-0AV0 WinCC flexible 2008
€ 2.495,00
The Siemens 6AV6381-2BN08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.
WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software includes tools for screen design, alarm management, recipe handling, trend displays, and report generation. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. The platform provides integrated simulation functionality, allowing projects to be tested on a PC before deployment to the target hardware.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, packaging, and chemical processing. It is suitable for projects requiring centralized HMI engineering with consistent visualization across multiple panel types. The software's scalability makes it applicable for both small standalone machine HMIs and larger distributed operator station networks.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| Compatible HMI Devices | SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Simulation | Integrated PC-based project simulation |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Integrated recipe editor and runtime handling |
| Trend Display | Integrated trend and data logging functions |
| Report Generation | Integrated report system |
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Single-user software license |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000
- Project compilation error — one or more configuration errors detected during project build.
Review the output window for specific error messages, correct the configuration issues in the affected screens or connections, and recompile the project. - Event ID: 1010
- Communication connection to PLC could not be established at runtime.
Verify PLC address settings, check physical network or bus connections, confirm the correct communication driver is configured, and ensure the PLC is powered and online. - Event ID: 1020
- Tag read/write error — a configured tag could not be read from or written to the PLC.
Check that the tag address exists in the PLC program, verify data type consistency between HMI tag and PLC variable, and confirm communication is active. - Event ID: 1030
- License not found — no valid WinCC flexible runtime license detected on the target device.
Install or transfer a valid runtime license to the target HMI device using the Siemens Automation License Manager (ALM). - Event ID: 1040
- Project transfer failed — download to target HMI panel was interrupted or unsuccessful.
Check the transfer cable or network connection, verify the correct transfer channel is selected, ensure the HMI panel is in transfer mode, and retry the download. - Event ID: 1050
- Alarm buffer overflow — the alarm log has exceeded its configured capacity.
Increase the alarm buffer size in the project settings, archive older alarm records, or reduce the frequency of alarm events in the application. - Event ID: 1060
- Recipe data error — recipe record could not be read or written correctly.
Verify recipe configuration, check that all recipe tags are correctly mapped to PLC addresses, and confirm sufficient storage space is available on the HMI device. - Event ID: 1070
- Screen object rendering error — one or more graphical objects could not be displayed correctly.
Check the object configuration for invalid property values, verify that referenced images or symbols exist in the project, and recompile and retransfer the project.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI devices including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77B, TP 177B), Multi Panels, and Panel PCs running WinCC flexible Runtime.
Which PLC families can WinCC flexible 2008 communicate with?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC DA interfaces.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10; users requiring Windows 10 compatibility should consider migrating to WinCC (TIA Portal).
Can projects created in WinCC flexible 2008 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects, though some manual rework may be required depending on the complexity of the project.
Does 6AV6381-2BN08-0AV0 include runtime licenses for HMI panels?
The 6AV6381-2BN08-0AV0 is an engineering software license for the WinCC flexible 2008 configuration environment. Separate runtime licenses are required for each target HMI panel and must be managed via the Siemens Automation License Manager.
Troubleshooting
Project fails to compile with multiple errors after opening an existing project
Check the output/error window for specific error descriptions. Commonly caused by missing tag references, incompatible device version settings, or corrupted project files.
Update the target device version in project settings to match the actual HMI hardware, resolve all missing tag or screen references, and recompile. If the project file is corrupted, restore from a backup copy.
Transfer to HMI panel fails with 'No connection to device' message
Verify the transfer channel configuration (USB, Ethernet, or MPI/PROFIBUS) in the Transfer Settings dialog. Check physical cable connections and confirm the panel is set to Transfer mode.
Ensure the correct COM port or IP address is configured in the transfer settings, place the HMI panel in Transfer mode via its Start Center, and retry the transfer. Replace the transfer cable if a hardware fault is suspected.
Runtime license error displayed on HMI panel after project transfer
The HMI panel does not have a valid WinCC flexible Runtime license installed. Check the license status using the Siemens Automation License Manager on a connected PC.
Use the Automation License Manager (ALM) to transfer a valid WinCC flexible Runtime license to the target HMI panel. Ensure the license matches the required runtime size (number of tags/PowerTags).
PLC tags show invalid or dashes at runtime on the HMI panel
Communication between the HMI panel and PLC is not established or is intermittent. Check the connection status indicator in the HMI runtime and verify network or bus wiring.
Confirm the PLC IP address or MPI/PROFIBUS address in the HMI project matches the actual PLC configuration. Check network cables, PROFIBUS termination resistors, and PLC operating state. Re-download the project if connection parameters were changed.
WinCC flexible 2008 engineering software will not install on the PC
Installation may fail due to incompatible operating system version, insufficient user privileges, or conflicts with previously installed Siemens software components.
Verify the PC meets the minimum system requirements (Windows XP/Vista/7, sufficient RAM and disk space). Run the installer as Administrator, uninstall conflicting Siemens software versions, and ensure the Automation License Manager is installed prior to the main software installation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page



