Siemens 6AV6381-2BN08-0AH0 SIMATIC WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2BN08-0AH0 is a software license for SIMATIC WinCC flexible 2008, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels within the SIMATIC automation environment. This product belongs to the WinCC flexible product family, which serves as the central configuration tool for the full range of SIMATIC HMI operator panels, from Micro Panels up to Multi Panels and PC-based systems. The software enables engineers to design, program, and manage visualization projects for industrial operator interfaces.
WinCC flexible 2008 provides a comprehensive set of engineering tools including a graphical project editor, tag management, alarm logging, trend displays, recipe management, and report generation. The software supports multiple communication drivers and protocols, enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs as well as third-party controllers via OPC. It includes a simulation function allowing project testing on a PC without physical hardware, and supports multi-language project management for international deployments. The 2008 edition introduced improved performance, extended library objects, and enhanced integration with STEP 7.
SIMATIC WinCC flexible 2008 is used across a broad range of industries including automotive manufacturing, food and beverage processing, pharmaceutical production, water treatment, and machine building. It is the standard engineering environment for OEMs and system integrators who deploy SIMATIC HMI panels in standalone machines or distributed plant-wide SCADA architectures. Its scalability from small panel applications to complex multi-panel installations makes it suitable for both compact machine-level HMI and larger supervisory visualization systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Series/Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Supported HMI Devices | SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs |
| Supported PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200, third-party via OPC |
| Communication Protocols | MPI, PROFIBUS DP, PROFINET, Ethernet, OPC |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Simulation | Integrated PC-based project simulation |
| Language Support | Multi-language project management |
| Tag Management | Integrated tag editor with cross-reference function |
| Alarm Logging | Discrete and analog alarm management with archiving |
| Recipe Management | Integrated recipe editor and runtime management |
| Report Generation | Integrated report system for logging and printing |
| Integration | STEP 7 integrated and standalone operation supported |
Common Error Codes and System Events
- Error 1920
- License not found or license server not reachable during software startup.
Verify that the correct license key is installed using the Automation License Manager. Ensure the license dongle is connected or the software license is properly transferred to the engineering PC. - Error 2541
- Project compilation failed due to inconsistent tag references or missing device configuration.
Open the project editor, check for invalid tag references in the cross-reference list, correct any missing or mismatched PLC connections, and recompile the project. - Error 1722
- Runtime installation error during WinCC flexible setup, typically caused by missing or corrupt Windows Installer components.
Repair or reinstall the Windows Installer service, ensure all prerequisites (.NET Framework, Visual C++ redistributables) are installed, then re-run the WinCC flexible setup. - Error 3010
- Restart required after installation; setup completed but system changes are pending.
Save all open work and restart the engineering PC to complete the installation process. - Communication Error
- No connection to the configured HMI device during project download or online operation.
Check the physical communication cable and interface settings (MPI address, PROFIBUS baud rate, or Ethernet IP address). Verify that the HMI panel is powered and in transfer mode. - Compilation Warning: Overlap
- Address overlap detected between two or more tags assigned to the same PLC data area.
Review tag assignments in the tag editor and resolve address conflicts by reassigning unique addresses to each tag. - License Downgrade Warning
- The project was created with a higher edition of WinCC flexible than the currently licensed version.
Upgrade the WinCC flexible license to the required edition, or reduce the project scope to match the capabilities of the installed license tier. - Device Type Mismatch
- The HMI device type configured in the project does not match the physical device detected during download.
Verify the target HMI panel model in the project properties and ensure it matches the physical hardware. Update the device type in the project if necessary and recompile before downloading.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2008 (6AV6381-2BN08-0AH0)?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels (MP 277, MP 377), and Panel PCs. The specific panels supported depend on the installed edition of the software.
Can WinCC flexible 2008 communicate with non-Siemens PLCs?
Yes, WinCC flexible 2008 supports communication with third-party controllers via OPC DA client/server interfaces. Direct driver support is primarily focused on SIMATIC S7 PLC families, but OPC connectivity allows integration with a wide range of automation systems.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10 or later operating systems. For Windows 10 compatibility, Siemens recommends migrating to WinCC (TIA Portal).
Can projects created in WinCC flexible 2008 be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required depending on the complexity of the project and the target HMI device.
Does this software include a runtime license for PC-based visualization?
The 6AV6381-2BN08-0AH0 is an engineering software license for project configuration. A separate WinCC flexible Runtime license is required if the project is to be executed on a PC-based HMI system rather than a dedicated SIMATIC panel.
Troubleshooting
Software fails to start and displays a license error on launch
Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2008 license is present and assigned to the local computer. Check for expired trial licenses or missing license keys.
Transfer or install the correct license using the Automation License Manager. If using a USB dongle, ensure it is connected before launching the software. Contact Siemens license support if the license file is corrupted.
Project download to HMI panel fails with a communication timeout
Check the physical connection between the engineering PC and the HMI panel (USB, MPI, PROFIBUS, or Ethernet cable). Verify the panel is powered on and set to transfer mode. Confirm the communication interface settings in the project match the panel configuration.
Set the HMI panel to transfer mode manually via the panel's Start Center. Verify the correct COM port or network adapter is selected in WinCC flexible's transfer settings. Replace the communication cable if continuity testing reveals a fault.
Compiled project generates multiple tag address overlap warnings
Use the cross-reference function in WinCC flexible to identify all tags sharing the same PLC data block address. Overlapping addresses typically result from copy-paste errors during tag creation or incorrect manual address entry.
Reassign unique and non-overlapping addresses to each affected tag in the tag editor. Recompile the project after corrections and verify that no further overlap warnings are generated.
Simulation function does not launch or crashes immediately
Check that all required Visual C++ redistributable packages and .NET Framework versions are correctly installed on the engineering PC. Verify that no antivirus software is blocking the simulation executable.
Reinstall the WinCC flexible 2008 software using the repair option to restore missing runtime components. Add the WinCC flexible simulation executable to the antivirus exclusion list if blocking is confirmed.
Alarm displays in the HMI project do not show alarm text at runtime
Verify that alarm texts are correctly configured in the alarm editor and that the correct language is set as the active runtime language. Check that the alarm tag connections reference valid PLC addresses.
Review the alarm configuration in the alarm editor, ensure alarm texts are entered for all configured languages, and confirm that the PLC tags referenced by alarms are correctly mapped. Re-download the project to the HMI panel after corrections.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page