Siemens 6AV6381-2BN07-5AH0 SIMATIC WinCC flexible
€ 1.995,00
The Siemens 6AV6381-2BN07-5AH0 is a software license package for SIMATIC WinCC flexible, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels within the SIMATIC automation environment. This product belongs to the WinCC flexible family, which serves as the central engineering tool for programming operator panels ranging from Micro Panels to Multi Panels and PC-based HMI systems. The software enables project creation, visualization design, and runtime configuration for a wide range of Siemens HMI hardware.
WinCC flexible provides a comprehensive set of engineering features including drag-and-drop screen design, tag management, alarm logging, recipe management, and trend displays. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. The software includes a library of pre-built faceplates and symbols, supports multi-language project configuration, and offers simulation capabilities for offline testing of HMI projects without requiring physical hardware.
This software package is widely used in manufacturing, process automation, machine building, and plant engineering applications where operator interface configuration is required. It is particularly suited for OEMs and system integrators who need to develop standardized HMI solutions across multiple machine types. Industries such as automotive, food and beverage, pharmaceuticals, and water treatment commonly deploy WinCC flexible-based HMI systems for process monitoring and control.
Technical Specifications
| Software Type | HMI Engineering Software |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| Compatible HMI Hardware | SIMATIC Micro Panels, OP/TP Panels, Multi Panels, Mobile Panels |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Operating System | Microsoft Windows (PC-based installation) |
| License Type | Single-user software license |
| Project Simulation | Integrated offline simulator included |
| Language Support | Multi-language project configuration |
| Certifications | CE |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Integrated recipe editor and runtime support |
Common Error Codes & System Events
- Event ID: 1000001
- Communication error between WinCC flexible Runtime and the connected PLC. The HMI cannot establish or maintain a connection to the controller.
Check network cable connections and communication settings. Verify PLC address, subnet, and protocol configuration in the WinCC flexible project. Ensure the PLC is in RUN mode. - Event ID: 1000002
- Tag read/write error. A configured tag cannot be read from or written to the PLC.
Verify the tag address in the WinCC flexible project matches the actual PLC memory address. Check PLC program for address conflicts or data type mismatches. - Event ID: 1000003
- License not found or invalid license detected for WinCC flexible Runtime or Engineering software.
Check that the software license dongle (USB or Automation License Manager) is correctly installed and recognized. Re-activate the license using Siemens Automation License Manager. - Event ID: 1000004
- Project download failed. Transfer of the HMI project to the target panel was unsuccessful.
Verify the communication channel between the engineering PC and the HMI panel. Check that the panel is in Transfer mode and that the correct interface (USB, Ethernet, or MPI) is selected in the transfer settings. - Event ID: 1000005
- Runtime startup error. WinCC flexible Runtime failed to start the project on the HMI device.
Check available memory on the HMI device. Verify project compatibility with the target panel firmware version. Re-download the project and update panel firmware if necessary. - Event ID: 1000006
- Alarm buffer overflow. The number of pending alarms has exceeded the configured alarm buffer capacity.
Acknowledge and clear active alarms. Increase the alarm buffer size in the WinCC flexible project settings or implement alarm archiving to an external data store. - Event ID: 1000007
- Recipe data error. A recipe record could not be read from or written to the configured data medium.
Check the recipe configuration in the project for correct tag assignments and data types. Verify that the storage medium (internal memory or memory card) is available and not write-protected.
Frequently Asked Questions
Which Siemens HMI panels are compatible with WinCC flexible 6AV6381-2BN07-5AH0?
WinCC flexible supports a wide range of SIMATIC HMI panels including Micro Panels, OP/TP operator panels, Multi Panels, and Mobile Panels. The specific edition of the software determines which panel types and project sizes are supported.
Which PLCs can be connected to an HMI project configured with WinCC flexible?
WinCC flexible supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party PLC connectivity may also be available through OPC or specific drivers.
Can WinCC flexible projects be simulated without physical HMI hardware?
Yes, WinCC flexible includes an integrated simulator that allows offline testing of HMI projects on the engineering PC without requiring a physical panel or PLC connection.
Is WinCC flexible compatible with TIA Portal?
WinCC flexible is a separate engineering environment from TIA Portal. Siemens provides a migration tool to convert WinCC flexible projects to WinCC in TIA Portal, but the two environments are not directly interchangeable.
What operating system is required to run WinCC flexible engineering software?
WinCC flexible runs on Microsoft Windows operating systems. Refer to the Siemens product documentation for the specific Windows versions supported by this software release.
Troubleshooting
HMI project cannot be transferred to the panel
Check the transfer interface selected in WinCC flexible Transfer settings. Verify the panel is set to Transfer mode. Test the physical connection (USB, Ethernet, or MPI cable).
Ensure the correct communication interface is selected and the panel is in Transfer mode. Replace the communication cable if faulty. Confirm that firewall or antivirus software on the engineering PC is not blocking the transfer port.
WinCC flexible software reports license error on startup
Open Siemens Automation License Manager and check whether a valid license for WinCC flexible is present and assigned. Verify the USB license dongle is recognized by the PC.
Re-insert the USB license dongle and restart the Automation License Manager. If the license is stored on a network server, verify network connectivity to the license server. Contact Siemens support to reactivate a lost or corrupted license.
Runtime communication fault displayed on HMI panel after project download
Check the PLC communication parameters configured in the WinCC flexible project (IP address, MPI address, or PROFIBUS address). Verify the physical network connection between the HMI panel and the PLC.
Correct any mismatched communication parameters in the project and re-download. Replace network cables or connectors if physical faults are found. Ensure the PLC is powered and in RUN mode.
Alarms are not displayed correctly or alarm history is missing
Check the alarm configuration in the WinCC flexible project for correct trigger tag assignments and alarm classes. Verify that the alarm buffer size is sufficient and that archiving is correctly configured.
Correct tag assignments and alarm class settings in the project. Increase the alarm buffer size if overflow events are logged. Re-download the updated project to the HMI panel.
Project opens with errors after migrating from an older WinCC flexible version
Review the migration log generated during project opening for specific incompatibility warnings. Check for deprecated functions, unsupported panel types, or tag limit exceedances.
Address each error listed in the migration log by updating deprecated functions to current equivalents. Verify that the target panel type is supported by the installed WinCC flexible version and update the project configuration accordingly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page