• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BM08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BM08-0AX0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BM08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BM08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software includes libraries of pre-built faceplates, tag management, alarm logging, trend displays, and recipe management functions. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLC families. The 2008 edition introduced enhanced usability features, improved project migration tools, and expanded device support compared to earlier versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where SIMATIC HMI panels are deployed. It is suitable for applications in automotive production lines, food and beverage processing, packaging machinery, and water treatment facilities. The software enables engineers to design consistent, scalable HMI solutions that can be reused across different panel types and project sizes.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Compatible HMI Devices SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI
    Compatible PLCs SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet, USB
    Operating System Windows XP, Windows Vista, Windows 7
    Project Migration Supports migration from ProTool and earlier WinCC flexible versions
    Alarm Management Integrated alarm logging and display
    Recipe Management Integrated recipe editor and runtime management
    Trend Display Integrated trend and data logging functions
    Language Support Multi-language project support
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000
    Project compilation error — one or more configuration errors detected during project build.
    Review the error list in the output window, correct all flagged configuration issues, and recompile the project.
    Event ID: 1010
    Communication connection to PLC could not be established during runtime.
    Verify PLC address settings, check physical network or bus connections, and confirm the correct communication driver is configured in the project.
    Event ID: 1020
    Tag read/write error — a configured tag could not be read from or written to the connected controller.
    Check that the tag address in the HMI project matches the actual PLC data block or memory address. Verify PLC program is running.
    Event ID: 1030
    License not found — no valid WinCC flexible runtime license detected on the target device.
    Install a valid runtime license on the target HMI device using the Siemens Automation License Manager (ALM).
    Event ID: 1040
    Project download failed — transfer of the compiled project to the HMI panel was interrupted or unsuccessful.
    Check the transfer cable or network connection, ensure the HMI panel is in transfer mode, and retry the download.
    Event ID: 1050
    Alarm buffer overflow — the number of active or pending alarms has exceeded the configured buffer size.
    Increase the alarm buffer size in the project settings or acknowledge and clear existing alarms to free buffer space.
    Event ID: 1060
    Recipe data error — recipe records could not be read from or written to the configured storage location.
    Check the storage medium (internal flash, memory card) for available space and integrity. Verify recipe configuration in the project.
    Event ID: 1070
    Screen object configuration error — one or more screen objects reference tags or resources that do not exist in the project.
    Open the affected screen in the engineering tool, resolve all broken tag references, and recompile the project before downloading.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (KTP series), Mobile Panels, Operator Panels (OP series), Multi Panels (MP series), and PC-based HMI systems running WinCC flexible Runtime.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1200 PLCs?

    Yes, WinCC flexible 2008 includes support for SIMATIC S7-1200 PLCs via Ethernet/PROFINET communication, though TIA Portal with WinCC is the recommended engineering environment for newer S7-1200 and S7-1500 projects.

    Can projects created in earlier versions of WinCC flexible be migrated to WinCC flexible 2008?

    Yes, WinCC flexible 2008 includes a migration tool that supports importing projects from ProTool and earlier WinCC flexible versions (2004, 2005, 2007).

    What operating systems are supported for running the WinCC flexible 2008 engineering software?

    WinCC flexible 2008 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 (32-bit and 64-bit editions).

    Is a separate runtime license required for each HMI panel?

    Yes, each target HMI device running a WinCC flexible Runtime project requires its own valid runtime license, managed through the Siemens Automation License Manager (ALM).

    Troubleshooting

    Software installation fails or aborts partway through

    Check Windows Event Viewer for installation error codes. Verify that the PC meets minimum system requirements and that no conflicting Siemens software versions are installed.

    Uninstall any conflicting or older versions of WinCC flexible using the Siemens Uninstall Tool, ensure .NET Framework and Visual C++ redistributables are up to date, then reinstall 6AV6381-2BM08-0AX0.

    Project cannot be compiled — multiple errors reported in output window

    Review each error in the output window. Common causes include broken tag references, missing communication drivers, or incompatible device type settings.

    Correct all broken tag references, verify the target HMI device type matches the physical panel, and ensure all required communication drivers are installed before recompiling.

    Project download to HMI panel fails or times out

    Check the transfer connection (USB, Ethernet, or MPI/PROFIBUS). Confirm the HMI panel is set to transfer mode and that the correct transfer channel is selected in the project settings.

    Restart the HMI panel in transfer mode, verify the IP address or bus address settings match the engineering PC configuration, and retry the download using the correct transfer channel.

    Runtime license error displayed on HMI panel after project start

    The HMI panel does not have a valid WinCC flexible Runtime license installed. Check the Automation License Manager on the panel or engineering PC.

    Use the Siemens Automation License Manager (ALM) to transfer a valid runtime license to the target HMI device. Ensure the license matches the required runtime size (number of tags/variables).

    PLC communication fails at runtime — tags show error state

    Verify the PLC is powered and in RUN mode. Check network or bus cabling between the HMI panel and PLC. Confirm the PLC address configured in the HMI project matches the actual PLC settings.

    Correct the PLC address in the HMI project connection settings, check and replace any faulty cables, and ensure the correct communication protocol and driver are configured for the connected PLC type.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart