• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BM08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BM08-0AV0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BM08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BM08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based systems. The software includes features such as faceplates, scripts (VBScript), alarm management, trend displays, recipe management, and user administration. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). The software also supports integration with WinCC (SCADA) and offers multilingual project support for up to 32 languages.

    WinCC flexible 2008 is widely used in manufacturing, process automation, packaging machinery, and material handling applications. It is suitable for machine builders and system integrators who require a consistent engineering tool across multiple HMI device classes. The software's scalability makes it applicable in both small standalone machine panels and larger distributed HMI architectures within factory automation environments.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Supported HMI Hardware SIMATIC Micro Panels, OP/TP Panels, Multi Panels, Panel PCs
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (PROFINET)
    Scripting Support VBScript
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Multilingual Support Up to 32 languages
    User Administration Included
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes & System Events

    Event ID: 1000
    Project could not be opened due to version incompatibility between the project file and the installed WinCC flexible version.
    Ensure the correct version of WinCC flexible is installed. Migrate the project using the project migration tool if upgrading from an older version.
    Event ID: 1010
    Communication error between the HMI panel and the PLC. The configured connection cannot be established.
    Check physical connections (MPI cable, PROFIBUS cable, or Ethernet cable). Verify PLC address settings and communication parameters in the WinCC flexible project match the PLC configuration.
    Event ID: 1020
    License not found or license is invalid. The software cannot start in full mode.
    Verify that the correct license key (Automation License Manager) is installed and active. Re-install the license using the Siemens Automation License Manager tool.
    Event ID: 1030
    Download to HMI panel failed. Transfer connection could not be established.
    Check that the HMI panel is in transfer mode. Verify the correct transfer channel (MPI, PROFIBUS, or Ethernet) and address are configured in the project settings.
    Event ID: 1040
    Runtime error on HMI panel: project file is corrupted or incompatible with the panel firmware version.
    Re-download the project to the panel. If the issue persists, update the panel firmware to a version compatible with WinCC flexible 2008 and re-transfer the project.
    Event ID: 1050
    Tag limit exceeded. The number of configured tags in the project exceeds the license or panel limit.
    Reduce the number of tags in the project or upgrade the WinCC flexible license to a higher tag count tier. Check panel specifications for maximum supported tag count.
    Event ID: 1060
    Script execution error. A VBScript in the project encountered a runtime error.
    Review the VBScript code in the affected function or event. Check for null references, incorrect tag names, or unsupported functions. Use the WinCC flexible simulator to debug scripts before downloading.

    Frequently Asked Questions

    Which Siemens PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET).

    What operating systems are supported by WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 (32-bit editions). It is not natively supported on Windows 10 or Windows 11.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, WinCC flexible 2008 projects can be migrated to Siemens TIA Portal using the integrated migration tool available within TIA Portal. Some manual rework may be required after migration depending on project complexity.

    What HMI panels can be configured with WinCC flexible 2008?

    The software supports a wide range of SIMATIC HMI panels including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), and Panel PCs.

    Is a separate runtime license required for the HMI panel?

    The engineering software license (6AV6381-2BM08-0AV0) covers project creation. The HMI panel itself contains an embedded WinCC flexible Runtime license; no separate runtime license is typically required for standard SIMATIC panels.

    Troubleshooting

    Software fails to start or runs in demo mode after installation

    Check the Siemens Automation License Manager to verify that a valid license for WinCC flexible 2008 is installed and not expired or moved to another machine.

    Re-install or transfer the license using the Automation License Manager. Ensure the license dongle (if applicable) is connected, or activate the software license on the correct machine.

    Project download to HMI panel fails with a connection error

    Verify that the HMI panel is set to transfer mode and that the correct communication channel and address are configured in both the panel settings and the WinCC flexible project.

    Set the panel to transfer mode via the Start Center. Confirm IP address or MPI/PROFIBUS address settings match the project configuration. Check cables and network switches if using Ethernet.

    WinCC flexible 2008 cannot open a project created in an older version

    The project file format may be incompatible with the installed version of WinCC flexible. Check the project version information in the file properties.

    Use the WinCC flexible project migration wizard to upgrade the project file to the 2008 format. Back up the original project before migration.

    Simulation of the project on the PC does not reflect PLC tag values

    The simulator may not be connected to a live PLC. WinCC flexible's built-in simulator operates in offline mode by default and does not establish a live PLC connection without additional configuration.

    Use the PLCSIM tool in conjunction with WinCC flexible simulation for S7-300/400 projects, or connect directly to a live PLC via the configured communication channel for real-time tag simulation.

    HMI panel displays 'No connection to PLC' alarm at runtime

    Check the physical communication link between the panel and PLC. Verify that the PLC is in RUN mode and that the communication parameters (address, baud rate, protocol) match the project configuration.

    Inspect and replace communication cables if damaged. Confirm PLC address and communication settings in both the PLC hardware configuration and the WinCC flexible connection settings. Restart both the panel and PLC if necessary.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart