• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BP07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BP07-5AV0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BP07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BP07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides a comprehensive SCADA and HMI configuration environment used to develop visualization projects for Siemens operator panels and HMI devices. It is designed to run on standard engineering PCs and integrates tightly with the Siemens SIMATIC automation ecosystem.

    WinCC flexible 2007 offers a project-based engineering environment with support for a wide range of Siemens HMI hardware targets, including the TP, OP, MP, and Mobile Panel series. The software supports tag-based communication with SIMATIC S7-200, S7-300, S7-400, and WinCC Runtime targets via MPI, PROFIBUS, and Ethernet interfaces. It includes features such as alarm management, trend displays, recipe management, user administration, and multi-language project support. The 2007 edition introduced improved performance, extended device support, and enhanced migration tools for converting projects from ProTool and earlier WinCC flexible versions.

    This software is used by automation engineers and system integrators to develop HMI applications across a broad range of industries, including automotive manufacturing, food and beverage processing, packaging machinery, and water treatment facilities. It is particularly suited for machine-level visualization tasks where tight integration with Siemens PLCs and standardized project structures are required. The software supports scalable project development, allowing engineers to reuse templates and objects across multiple machine types and panel variants.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Single-user software license
    Compatible HMI Hardware SIMATIC TP, OP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet
    Operating System Windows XP, Windows Vista (32-bit)
    Engineering Environment PC-based engineering software
    Project Features Alarm management, recipe management, trend displays, user administration
    Language Support Multi-language project configuration
    Migration Support ProTool and earlier WinCC flexible project migration
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000001
    Communication error between engineering PC and target HMI device during project download.
    Check the communication interface settings (MPI address, baud rate, or Ethernet IP address). Verify the PC adapter or network connection is properly configured and the target device is powered on.
    Event ID: 1000010
    License not found or license key is invalid for the installed WinCC flexible version.
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Event ID: 1000020
    Project compilation error due to inconsistent tag or screen configuration.
    Review the error log in the compiler output window. Correct any invalid tag references, missing connections, or unsupported object properties for the target device.
    Event ID: 1000030
    Runtime simulation failure on the engineering PC.
    Ensure WinCC flexible Runtime is installed and licensed. Check that no other simulation instance is already running and that the PC meets minimum system requirements.
    Event ID: 1000040
    Device type mismatch between project configuration and connected HMI hardware.
    Verify the target device type selected in the project matches the physical HMI panel. Use the device change wizard to migrate the project to the correct target if needed.
    Event ID: 1000050
    Migration error when importing a ProTool or earlier WinCC flexible project.
    Run the migration wizard and review the migration log for unsupported objects or features. Manually recreate any elements that could not be automatically converted.
    Event ID: 1000060
    Tag limit exceeded for the selected HMI target device.
    Reduce the number of configured tags to within the limit supported by the target panel. Consider upgrading to a higher-tier HMI device if more tags are required.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of Siemens SIMATIC HMI panels including the TP 170, TP 270, OP 270, MP 277, MP 377, and Mobile Panel 177/277 series, among others. The specific device list is documented in the WinCC flexible 2007 release notes.

    Which PLCs can communicate with projects developed in WinCC flexible 2007?

    Projects can communicate with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, or Industrial Ethernet. Third-party PLC communication is also possible through OPC DA connections.

    Is WinCC flexible 2007 compatible with Windows 10?

    WinCC flexible 2007 was designed for Windows XP and Windows Vista (32-bit) and is not officially supported on Windows 10. Running it on newer operating systems may cause compatibility issues and is not recommended for production use.

    Can existing ProTool projects be migrated to WinCC flexible 2007?

    Yes, WinCC flexible 2007 includes a migration wizard that can convert ProTool projects and earlier WinCC flexible versions. Some objects or features may not migrate automatically and will require manual recreation.

    What is the Automation License Manager (ALM) and is it required?

    The Siemens Automation License Manager is a tool used to manage software licenses for Siemens engineering software, including WinCC flexible. It is required to activate and validate the 6AV6381-2BP07-5AV0 license before the software can be used.

    Troubleshooting

    Software fails to start after installation and displays a license error

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2007 license is present and assigned to the local machine.

    Transfer or reinstall the license using the ALM tool. Ensure the license matches the installed software version and edition. If the license dongle is used, verify it is properly connected.

    Project download to HMI panel fails with a communication error

    Check the communication settings in the project transfer dialog. Verify the correct interface (MPI, PROFIBUS, or Ethernet) is selected and that the PC adapter or network card is properly configured.

    Correct the interface settings, ensure the HMI panel is in transfer mode, and retry the download. For Ethernet transfers, verify IP address settings on both the PC and the panel.

    Compiler reports errors when building the project

    Review the compiler output window for specific error messages referencing tags, screens, or connections. Identify any invalid tag addresses, missing PLC connections, or unsupported features for the selected target device.

    Correct all flagged errors in the project configuration. Ensure tag addresses are valid for the connected PLC type and that all referenced screens and objects exist within the project.

    WinCC flexible Runtime simulation does not launch on the engineering PC

    Check whether WinCC flexible Runtime is installed as a separate component and whether a valid Runtime license is present in the Automation License Manager.

    Install the Runtime component if missing and ensure a Runtime license is available. Close any existing simulation sessions before starting a new one.

    Migrated project from ProTool contains missing or incorrectly converted screens

    Review the migration log generated by the migration wizard to identify objects or features that were not fully converted.

    Manually recreate any unsupported objects in WinCC flexible 2007. Refer to the WinCC flexible migration documentation for guidance on equivalent replacement objects and configurations.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart