
Siemens 6AV6381-2BF08-0AH0 WinCC flexible 2008
€ 2.495,00
The Siemens 6AV6381-2BF08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports a wide range of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC. It includes a library of pre-built faceplates and graphic objects, and supports multi-language project configuration for international deployments. The platform supports both panel-based and PC-based runtime environments, with scalable licensing options.
WinCC flexible 2008 is widely used in manufacturing, process automation, water treatment, energy management, and machine building industries. It is suitable for applications requiring centralized visualization and operator control across distributed SIMATIC HMI hardware, including the TP, OP, MP, and Mobile Panel series. The software's compatibility with the broader TIA (Totally Integrated Automation) ecosystem makes it a practical choice for facilities running mixed Siemens automation environments.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Engineering Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Protocols | PROFIBUS, MPI, PROFINET, OPC, Ethernet |
| Scripting Support | VBScript |
| Runtime Environment | Panel-based and PC-based |
| Compatible Panel Series | SIMATIC TP, OP, MP, Mobile Panel |
| Language Support | Multi-language project configuration |
| Operating System (Engineering PC) | Windows XP, Windows Vista, Windows 7 |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
| Alarm Logging | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — the WinCC flexible runtime failed to initialize correctly on the target device.
Verify that the correct runtime version is installed on the panel or PC. Check available memory and ensure no conflicting software is running. - Event ID: 1001
- Communication connection to PLC lost — the HMI project cannot establish or maintain a connection to the configured controller.
Check physical communication cables and network settings. Verify PLC address configuration in the WinCC flexible project matches the actual PLC settings. - Event ID: 1002
- Tag read/write error — a configured tag could not be read from or written to the PLC.
Confirm the tag address exists in the PLC program and that the data type matches the configuration in WinCC flexible. Check PLC program for address conflicts. - Event ID: 1003
- License not found — the software cannot find a valid license for the engineering or runtime component.
Verify the license dongle (USB) is connected or that the software license is correctly activated using the Siemens Automation License Manager (ALM). - Event ID: 1004
- Project transfer error — the project could not be transferred from the engineering PC to the target HMI panel.
Check the transfer connection (USB, Ethernet, or serial). Ensure the panel is in transfer mode and that the correct transfer settings are configured in WinCC flexible. - Event ID: 1005
- Alarm buffer overflow — the alarm log buffer on the HMI device has reached its maximum capacity.
Archive or clear the alarm log. Review alarm configuration to reduce unnecessary alarm generation and increase buffer size if supported by the target device. - Event ID: 1006
- Recipe data error — a recipe record could not be read or written correctly.
Check recipe configuration for data type mismatches or invalid values. Verify that the recipe memory on the target device is not full or corrupted. - Event ID: 1007
- Script execution error — a VBScript within the project encountered a runtime error.
Review the script code for syntax errors or invalid object references. Use the WinCC flexible diagnostic output to identify the specific line causing the error.
Frequently Asked Questions
Which SIMATIC HMI panels are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version and the edition of WinCC flexible 2008 licensed.
Does WinCC flexible 2008 support communication with S7-1200 PLCs?
Yes, WinCC flexible 2008 with the appropriate service pack supports communication with SIMATIC S7-1200 PLCs via Ethernet/PROFINET using the S7 communication driver.
What operating systems are supported for the engineering station running WinCC flexible 2008?
WinCC flexible 2008 is compatible with Windows XP (SP3), Windows Vista, and Windows 7 (32-bit and 64-bit editions). It is not officially supported on Windows 10 or later without compatibility workarounds.
Is a hardware dongle required to run WinCC flexible 2008?
A valid license managed through the Siemens Automation License Manager (ALM) is required. Depending on the license package, this may be tied to a USB dongle or a software-based license key.
Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, some manual rework may be required depending on the complexity of the project and the features used.
Troubleshooting
Project transfer to HMI panel fails repeatedly
Check the transfer connection type (USB, Ethernet, or serial MPI/PROFIBUS). Verify the panel is set to transfer mode by holding the appropriate key combination during startup or via the panel's control panel settings.
Ensure the correct transfer channel is selected in WinCC flexible under Transfer settings. Confirm the IP address or COM port matches the panel configuration. If using Ethernet, verify both devices are on the same subnet.
WinCC flexible 2008 software fails to install or crashes during installation
Check the Windows version and service pack level for compatibility. Review the installation log files located in the Windows temp directory for specific error codes.
Ensure the engineering PC meets the minimum system requirements. Disable antivirus software during installation and run the installer as Administrator. Install all required Microsoft prerequisites (e.g., .NET Framework, MDAC) before retrying.
Runtime on panel displays 'No connection' to PLC
Verify the communication cable integrity and connector seating. Check the PLC address and communication parameters configured in the WinCC flexible project against the actual PLC settings.
Correct any mismatched IP addresses, MPI addresses, or baud rates in the project. Re-transfer the corrected project to the panel. If using PROFIBUS, verify the bus termination resistors are correctly set.
Alarm system not logging events on the HMI panel
Check the alarm configuration in WinCC flexible to confirm alarm logging is enabled and that the correct alarm classes are set to be logged. Verify available storage space on the panel.
Enable logging for the relevant alarm classes in the project settings. If the panel storage is full, archive existing logs and clear the buffer. Re-transfer the project after making configuration changes.
License error appears when launching WinCC flexible engineering software
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and not expired or corrupted.
If using a USB dongle, reconnect it and refresh the ALM. If the license is software-based, use ALM to repair or reactivate it. Contact Siemens license support if the license shows as invalid after reconnection.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page



