• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BF08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BF08-0AV0 WinCC flexible 2008

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6381-2BF08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BF08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. WinCC flexible 2008 is an engineering software package used to configure, program, and commission SIMATIC HMI operator panels and visualization systems. It serves as the central development environment for creating HMI projects across a wide range of Siemens panel families.

    WinCC flexible 2008 provides a comprehensive set of engineering tools including a graphical editor for screen design, tag management, alarm configuration, recipe handling, and trend displays. The software supports integration with SIMATIC S7 PLCs via MPI, PROFIBUS, and PROFINET communication interfaces, and includes a simulation function for offline testing of HMI projects without physical hardware. It is compatible with the full range of SIMATIC HMI panels including Micro Panels, Mobile Panels, Operator Panels, Multi Panels, and Panel PCs, and supports migration of projects from earlier ProTool and WinCC flexible versions.

    WinCC flexible 2008 is used in manufacturing automation, process control, and machine building applications where SIMATIC HMI panels are deployed. It is suitable for industries such as automotive, food and beverage, packaging, and general factory automation. The software enables engineers to develop scalable visualization solutions ranging from small single-panel installations to distributed multi-panel systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user license
    Compatible HMI Families SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Communication Interfaces Supported MPI, PROFIBUS DP, PROFINET, Ethernet
    Simulation Function Integrated offline simulation
    Operating System Windows XP, Windows Vista, Windows 7
    Project Migration Supports migration from ProTool and earlier WinCC flexible versions
    Language Support Multi-language project engineering
    Alarm Management Integrated alarm logging and display
    Recipe Handling Integrated recipe management
    Trend Display Integrated trend and data logging
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during software startup
    Verify that the license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary.
    Error 2
    Project compilation error due to inconsistent tag configuration
    Open the project in WinCC flexible, navigate to the tag editor, and resolve all highlighted inconsistencies. Recompile the project after corrections.
    Error 3
    Communication connection to PLC cannot be established during simulation or runtime transfer
    Check the configured communication driver and connection parameters. Verify that the correct COM port, MPI address, or IP address is set and that the PC adapter or network interface is properly installed.
    Error 4
    Transfer to HMI panel fails with connection timeout
    Ensure the HMI panel is in transfer mode. Verify the transfer channel settings (USB, Ethernet, or MPI) match the panel configuration. Check cable connections and firewall settings on the engineering PC.
    Error 5
    Incompatible project version detected when opening an existing project
    Use the WinCC flexible migration wizard to convert the project from an older version. Back up the original project before migration.
    Error 6
    Insufficient disk space or memory during project compilation
    Free up disk space on the engineering PC. Close unnecessary applications to release RAM. Ensure the PC meets the minimum system requirements for WinCC flexible 2008.
    Error 7
    Runtime software version mismatch between engineering project and HMI panel
    Verify that the WinCC flexible Runtime version installed on the panel matches the version used in the engineering software. Update the panel runtime via the transfer function if required.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (TP 170 Micro, OP 73 Micro), Mobile Panels, Operator Panels (OP 77, TP 177, OP 177), Multi Panels (MP 277, MP 377), and Panel PCs.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted for use with WinCC in TIA Portal, though some manual rework may be required.

    What communication protocols does WinCC flexible 2008 support for PLC connectivity?

    WinCC flexible 2008 supports MPI, PROFIBUS DP, PROFINET, and Industrial Ethernet connections to SIMATIC S7 PLCs, as well as connections to third-party controllers via OPC.

    Does WinCC flexible 2008 include an offline simulation function?

    Yes, WinCC flexible 2008 includes an integrated simulator that allows HMI projects to be tested on the engineering PC without requiring a physical HMI panel or PLC connection.

    Is a hardware dongle required to run WinCC flexible 2008?

    The licensing method depends on the specific license variant purchased. Some versions use a USB hardware dongle managed through the Siemens Automation License Manager (ALM), while others use software-based licensing.

    Troubleshooting

    WinCC flexible 2008 fails to start and reports a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and not expired or corrupted.

    Transfer a valid license to the engineering PC using ALM. If using a USB dongle, ensure it is connected before launching the software. Reactivate or repair the license if it shows as defective.

    Project transfer to HMI panel fails repeatedly

    Check the transfer channel configuration in WinCC flexible under Transfer settings. Verify the panel is in transfer mode and the physical connection (USB, Ethernet, or MPI cable) is intact.

    Correct the transfer channel settings to match the panel interface. Replace the cable if faulty. Temporarily disable the Windows firewall to rule out network blocking during Ethernet transfers.

    Compiled project generates multiple tag or screen errors

    Review the output window in WinCC flexible after compilation to identify the specific objects or tags causing errors. Common causes include unconnected tags, missing PLC variables, or invalid address formats.

    Correct each reported error in the tag editor or screen editor. Ensure all tags reference valid PLC addresses and that the correct PLC driver is selected for the project.

    WinCC flexible 2008 crashes or freezes during project editing

    Check the engineering PC for adequate RAM and CPU resources. Verify that the installed operating system is compatible (Windows XP SP3, Windows Vista, or Windows 7) and that all Siemens software updates and service packs are applied.

    Install the latest WinCC flexible 2008 service pack from the Siemens support portal. Increase virtual memory on the PC if RAM is limited, and close other applications during editing of large projects.

    Existing project from an older WinCC flexible version cannot be opened

    WinCC flexible 2008 may not directly open projects created in significantly older versions such as WinCC flexible 2004 or ProTool without migration.

    Use the integrated migration wizard in WinCC flexible 2008 to convert the project. Always create a backup of the original project files before starting the migration process.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart