The Siemens 6AV6381-2BF07-5AH0 is a software license package for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create, configure, and manage visualization projects.
WinCC flexible 2007 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports a wide range of Siemens HMI hardware targets including the TP, OP, MP, and Mobile Panel series, as well as PC-based runtime environments. It provides communication drivers for SIMATIC S7-200, S7-300, S7-400, and other third-party controllers via standard protocols such as PROFIBUS, MPI, and Ethernet. The engineering environment runs on Windows-based PCs and supports project migration from earlier ProTool configurations.
WinCC flexible 2007 is used across manufacturing, process, and infrastructure industries wherever Siemens SIMATIC HMI panels are deployed. Typical applications include machine-level visualization on packaging lines, press systems, conveyor systems, and process plant control panels. The software is particularly suited for OEMs and system integrators who require a scalable, standardized HMI engineering platform compatible with the broader SIMATIC automation ecosystem.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Engineering Software License |
| Compatible HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel series |
| Controller Compatibility | SIMATIC S7-200, S7-300, S7-400, WinAC |
| Communication Interfaces | PROFIBUS, MPI, Industrial Ethernet (TCP/IP) |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Project Migration | Supports import from ProTool projects |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Supported |
| Trend Display | Supported |
| Scripting | VB Script support for extended functionality |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000001
- Communication error between engineering PC and HMI target device during download
Check the communication cable and interface settings. Verify the correct communication driver is selected and the target device IP address or MPI address is correctly configured. - Event ID: 1000002
- License not found or license key invalid
Verify the software license dongle (USB) is connected. Use the Siemens Automation License Manager to check license status and transfer a valid license if required. - Event ID: 1000010
- Project compilation error due to invalid tag configuration
Review the tag table for duplicate tag names, invalid data types, or missing controller connections. Correct the configuration and recompile the project. - Event ID: 1000020
- Runtime download failed — insufficient memory on target HMI device
Reduce the project size by removing unused images, tags, or archive data. Check the available user memory on the target panel and ensure it meets the project requirements. - Event ID: 1000030
- Incompatible runtime version on target device
Update the HMI panel runtime software to the version compatible with WinCC flexible 2007 using the ProSave tool or via the engineering software download function. - Event ID: 1000040
- Alarm archive overflow
Increase the alarm buffer size in the project settings or configure alarm archiving to an external storage medium. Clear the existing alarm archive on the target device. - Event ID: 1000050
- Recipe data transfer error
Check the recipe configuration for correct tag assignments and data types. Verify that the controller is online and the recipe data record is not corrupted.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the TP 177, TP 270, OP 270, MP 277, MP 377, and Mobile Panel 177 series, as well as PC-based runtime systems running WinCC flexible Runtime.
Is a hardware dongle required to run WinCC flexible 2007?
Yes, WinCC flexible 2007 requires a valid license managed through the Siemens Automation License Manager (ALM). The license can be stored on a USB dongle or transferred to the engineering PC's hard drive.
Can WinCC flexible 2007 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual rework may be required for complex projects, and not all features migrate automatically.
Which communication protocols does WinCC flexible 2007 support?
WinCC flexible 2007 supports PROFIBUS DP, MPI, Industrial Ethernet (TCP/IP), and includes drivers for SIMATIC S7-200, S7-300, S7-400 controllers as well as selected third-party PLCs via OPC.
What operating systems are compatible with WinCC flexible 2007 engineering software?
WinCC flexible 2007 is compatible with Windows XP Professional (SP2 or later), Windows Vista, and Windows 7 (32-bit editions). It is not officially supported on 64-bit operating systems without compatibility mode.
Troubleshooting
Software fails to install or reports a license error on startup
Check whether the Automation License Manager (ALM) detects a valid license. Open ALM and inspect the license status for WinCC flexible 2007.
Connect the USB license dongle if not already inserted. If the license is stored on the hard drive, use ALM to verify it has not been corrupted. Transfer a valid license from the original storage medium if necessary.
Project download to HMI panel fails with a communication error
Verify the physical connection between the engineering PC and the HMI panel. Check the selected communication interface (Ethernet, MPI, USB) and confirm the target device address matches the project settings.
Replace or reseat the communication cable. Confirm the HMI panel is powered on and in transfer mode. Correct the IP address or MPI address in the project communication settings and retry the download.
Compiled project generates errors related to undefined tags or missing connections
Open the tag editor and check for tags that reference a controller connection that is not configured or has been renamed. Use the cross-reference function to identify all affected tags.
Reassign the affected tags to the correct controller connection. Ensure all PLC connections are properly defined in the communication settings. Recompile the project after corrections.
HMI panel displays outdated screen content after project update
Confirm that the full project was downloaded and not just a partial update. Check the runtime version on the panel to ensure it matches the version used during engineering.
Perform a complete project download including all images and runtime components. If the runtime version is mismatched, update the panel runtime using ProSave before downloading the project again.
WinCC flexible 2007 crashes or becomes unresponsive during project editing
Check the engineering PC for sufficient RAM and disk space. Large projects with many images or archive configurations can exceed system resources on older hardware.
Close other running applications to free memory. Ensure the PC meets the minimum system requirements for WinCC flexible 2007. Save the project frequently and consider splitting large projects into smaller modular units.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page