• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BE08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BE08-0AX0 WinCC flexible 2008

    € 2.302,00

    Reset
    Clear
    SKU: 6AV6381-2BE08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BE08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment used to develop, commission, and manage HMI (Human-Machine Interface) applications for Siemens SIMATIC HMI panels. It is designed to work within the Siemens SIMATIC automation framework and is supplied as a licensed software package.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software provides tools for creating graphical process visualizations, alarm management, trend displays, recipe management, and user administration. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces, and includes project migration capabilities from earlier WinCC flexible versions.

    WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, process automation, food and beverage, automotive, and energy. It is particularly suited for machine builders and system integrators who need a consistent engineering tool to configure and maintain HMI panels across multiple machine types. The software's scalability allows it to serve both small standalone machine applications and larger distributed production systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single-user license
    Compatible HMI Devices SIMATIC Micro Panels, OP/TP Panels, Multi Panels, Mobile Panels
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Series/Product Family WinCC flexible
    Language Support Multilingual (project languages configurable)
    Alarm Management Supported
    Recipe Management Supported
    Trend Display Supported
    Project Migration Supported from earlier WinCC flexible versions

    Common Error Codes & System Events

    Error 1920
    Software license not found or license server unreachable during startup.
    Verify that the license key (dongle or software license) is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary.
    Error 1722
    Windows Installer package error during installation, indicating a problem with the installer or system configuration.
    Ensure the operating system meets minimum requirements. Run the installer as administrator and disable antivirus software temporarily during installation.
    Communication Error
    No connection established between WinCC flexible runtime and the target HMI panel during transfer.
    Check the communication cable and interface settings. Verify the correct COM port or Ethernet IP address is configured in the project transfer settings.
    Compiler Error
    Project compilation fails due to inconsistent or missing configuration elements.
    Review the compiler output log for specific missing tags, undefined connections, or unsupported functions. Correct the identified configuration errors and recompile.
    Transfer Error
    Project transfer to the HMI panel is interrupted or fails to complete.
    Ensure the HMI panel is in transfer mode. Check cable integrity, verify matching communication parameters, and confirm sufficient free memory on the target device.
    Runtime License Missing
    WinCC flexible Runtime license is not detected on the target HMI panel.
    Use the Automation License Manager to transfer a valid WinCC flexible Runtime license to the target panel's memory card or internal storage.
    Version Mismatch
    The engineering project version is incompatible with the Runtime version installed on the HMI panel.
    Update the HMI panel firmware to match the WinCC flexible 2008 version, or recompile the project using the appropriate software version for the panel's installed runtime.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), and Mobile Panels. Compatibility depends on the specific edition of WinCC flexible 2008 installed.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10 and may experience compatibility issues on that operating system. Siemens recommends migrating to TIA Portal for use on modern operating systems.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens TIA Portal includes a migration tool that can import WinCC flexible 2008 projects. However, some manual rework may be required after migration depending on the complexity of the project and the target HMI device.

    What communication protocols does WinCC flexible 2008 support for PLC connectivity?

    WinCC flexible 2008 supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) for communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as connections to third-party controllers via OPC.

    Does 6AV6381-2BE08-0AX0 include a Runtime license?

    The 6AV6381-2BE08-0AX0 is an engineering software license for WinCC flexible 2008. Runtime licenses for HMI panels are separate products and must be ordered independently based on the target panel type and size.

    Troubleshooting

    WinCC flexible 2008 fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 Engineering is present and not expired or corrupted.

    Transfer a valid license using ALM from the license storage medium (USB dongle or license file). If the license is corrupted, contact Siemens support for license recovery.

    Project transfer to HMI panel fails repeatedly

    Check the transfer settings in WinCC flexible for correct interface selection (USB, Ethernet, or serial). Verify the panel is set to transfer mode and the IP address or COM port matches the configuration.

    Correct the interface settings, ensure the communication cable is functional, and confirm the HMI panel has sufficient free memory. Restart both the PC and the HMI panel before retrying the transfer.

    Compilation errors appear when building the project

    Review the compiler output window for specific error messages referencing missing tags, undefined PLC connections, or unsupported object types for the selected target panel.

    Resolve each listed error by correcting tag definitions, verifying PLC connection parameters, and ensuring all used functions are supported by the target HMI device type and firmware version.

    WinCC flexible 2008 installation fails or rolls back

    Check the Windows Event Viewer for installation error codes. Confirm the PC meets the minimum hardware and OS requirements and that no conflicting software versions are installed.

    Uninstall any previous WinCC flexible versions cleanly using the Siemens uninstall tool, disable antivirus and UAC during installation, and run the installer with administrator privileges on a supported 32-bit Windows 7 system.

    HMI panel shows 'No project' after transfer appears successful

    Verify that the correct project file was compiled and transferred, and that the target device type selected in the project matches the physical HMI panel model and firmware version.

    Recompile the project after confirming the correct target device is selected, then perform a fresh transfer. If the issue persists, perform a factory reset on the HMI panel and re-transfer the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart