• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BE08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BE08-0AV0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BE08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BE08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create, configure, and manage visualization projects.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports a wide range of communication drivers and interfaces, enabling connectivity to SIMATIC S7 PLCs via MPI, PROFIBUS, and Industrial Ethernet (PROFINET). It includes project migration capabilities, multi-language support, and integration with STEP 7 for seamless engineering workflows within the Siemens TIA environment predecessor ecosystem.

    This software is widely used in manufacturing, process automation, food and beverage, automotive, and machine building industries. It is suitable for configuring operator panels such as the SIMATIC TP, OP, MP, and Mobile Panel series, as well as PC-based SCADA stations. Its scalability and broad panel compatibility make it a standard engineering tool for system integrators and OEMs working with Siemens HMI hardware.

    Technical Specifications

    Software Product WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Single License
    Version 2008
    Operating System Compatibility Windows XP, Windows Vista, Windows 7
    Communication Interfaces Supported MPI, PROFIBUS DP, PROFINET, Industrial Ethernet
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Supported Panel Families SIMATIC TP, OP, MP, Mobile Panel, Comfort Panel (via migration)
    Project Languages Up to 32 languages per project
    Integration STEP 7 V5.x integration supported
    Recipe Management Supported
    Alarm Logging Supported
    Trend Display Supported
    Script Support VB Script
    Certifications CE

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Siemens Automation License Manager (ALM). Reinstall the license if necessary.
    Error 2
    Communication driver not installed or missing for the selected PLC connection
    Reinstall the appropriate communication driver from the WinCC flexible installation media and ensure the correct interface is configured in the project.
    Error 3
    Project compilation error due to inconsistent tag configuration
    Open the project in the WinCC flexible editor, navigate to the tag table, and resolve any duplicate or invalid tag entries before recompiling.
    Error 4
    Transfer to HMI panel failed — connection timeout during project download
    Check the physical communication cable and interface settings. Verify the panel is in transfer mode and that the correct COM port or network address is configured in the transfer settings.
    Error 5
    Runtime startup failure on target panel after project transfer
    Confirm that the WinCC flexible Runtime version on the target panel matches the engineering software version. Update the panel runtime if a version mismatch is detected.
    Error 6
    Alarm buffer overflow — alarm log capacity exceeded
    Increase the alarm buffer size in the project settings or archive alarms to an external data storage location. Review alarm configuration to reduce unnecessary alarm events.
    Error 7
    Recipe data transfer error — mismatch between recipe structure and PLC data block
    Verify that the recipe tag assignments match the corresponding PLC data block structure. Recompile and re-transfer the project after correcting any structural inconsistencies.

    Frequently Asked Questions

    Which operating systems are compatible with WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without additional compatibility measures.

    Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted. Some manual rework may be required depending on the complexity of the project.

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the SIMATIC TP, OP, MP, and Mobile Panel series, as well as PC-based runtime systems. It covers panels ranging from Micro panels up to Multi Panels.

    Does WinCC flexible 2008 support PROFINET communication?

    Yes, WinCC flexible 2008 supports PROFINET and Industrial Ethernet communication in addition to MPI and PROFIBUS DP, enabling connectivity to modern SIMATIC S7 controllers.

    Is a separate runtime license required for the HMI panel?

    Yes, the HMI panel itself requires a WinCC flexible Runtime license, which is typically pre-installed on Siemens panels. The 6AV6381-2BE08-0AV0 engineering license covers the configuration software on the engineering PC.

    Troubleshooting

    Software fails to start after installation and reports a missing or invalid license

    Open the Siemens Automation License Manager (ALM) and check whether the WinCC flexible 2008 license is listed and shows a valid status.

    If the license is missing, transfer the license from the original license medium using ALM. If the license is shown as defective, contact Siemens support for license recovery.

    Project cannot be transferred to the HMI panel and a connection error is displayed

    Check the transfer cable connection, verify the panel is set to transfer mode, and confirm the correct interface (USB, Ethernet, or serial) and address are configured in the WinCC flexible transfer settings.

    Replace the communication cable if faulty, correct the interface settings in the Transfer dialog, and ensure no firewall or antivirus software is blocking the connection on the engineering PC.

    Compilation errors appear when building the project

    Review the output window in WinCC flexible for specific error messages. Common causes include duplicate tag names, invalid data type assignments, or missing screen references.

    Navigate to the flagged items using the error list, correct the tag table or screen configuration, and recompile the project until no errors remain.

    HMI panel displays a runtime version mismatch error after project download

    Compare the WinCC flexible Runtime version installed on the panel with the version of the engineering software used to create the project.

    Update the panel runtime to the matching version using the WinCC flexible installation media and the panel's update function via ProSave or the transfer settings.

    Alarm displays on the panel do not update or show stale data

    Check the communication status between the panel and the PLC. Verify that the alarm tags are correctly mapped to the PLC data addresses and that the PLC program is writing to the expected memory locations.

    Correct any tag address mismatches in the WinCC flexible project, ensure the PLC program logic is functioning correctly, and re-transfer the updated project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart