• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0JH0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0JH0 SIMATIC WinCC

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0JH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0JH0 is a WinCC (Windows Control Center) SCADA/HMI software package from Siemens, part of the SIMATIC HMI software family. This product belongs to the WinCC V7 generation and provides a comprehensive runtime and configuration environment for industrial visualization and process monitoring. It is designed to run on standard industrial PCs and workstations operating under Microsoft Windows.

    The 6AV6372-2DF07-0JH0 variant includes a defined number of PowerTags (process variables) for runtime operation, enabling connection to SIMATIC S7 PLCs as well as third-party controllers via OPC DA/UA interfaces. The software supports redundant server configurations, multi-client architectures, and offers integrated alarm management, trend displays, and historical data logging. Communication is supported via PROFIBUS, Industrial Ethernet (TCP/IP), and MPI, with drivers available for a wide range of Siemens and third-party controllers.

    WinCC is widely deployed in process industries such as chemical, pharmaceutical, water treatment, and energy management, as well as in discrete manufacturing environments including automotive assembly and machine tool applications. Its scalable architecture allows use in single-station installations as well as distributed multi-server SCADA systems, making it suitable for both small-scale machine HMI and plant-wide supervisory control applications.

    Technical Specifications

    Software Family SIMATIC WinCC V7
    Software Type SCADA / HMI Visualization Software
    Operating System Microsoft Windows (32/64-bit)
    Communication Interfaces PROFIBUS, Industrial Ethernet (TCP/IP), MPI, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, third-party via OPC
    Architecture Single-station, Client/Server, Redundant Server
    Data Logging Integrated process value and alarm archiving
    Alarm Management Integrated alarm logging and reporting
    Trend Display Online and historical trend visualization
    Scripting VBScript, ANSI-C scripting support
    Certifications CE, UL
    License Type Floating / Workstation license

    Common Error Codes & System Events

    Event ID: 1000001
    WinCC Runtime startup failure. The runtime environment could not be initialized, often due to missing or corrupt project files.
    Verify project file integrity, check Windows Event Viewer for detailed error messages, and reinstall WinCC Runtime if necessary.
    Event ID: 1000002
    Communication channel to PLC lost. The configured communication driver cannot establish or maintain a connection to the target controller.
    Check network cabling and IP/PROFIBUS addressing, verify PLC is in RUN mode, and confirm channel driver configuration in WinCC Explorer.
    Event ID: 1000003
    Tag logging database error. The process value archive cannot write data, typically due to a full disk or database corruption.
    Free disk space on the archive drive, run the WinCC Database Repair Tool, and check SQL Server service status.
    Event ID: 1000004
    License not found or invalid. WinCC Runtime cannot find a valid license for the configured number of PowerTags.
    Insert the correct license dongle (USB or SIMATIC Automation License Manager), verify the license count matches the project requirements.
    Event ID: 1000005
    Redundancy switchover event. The active WinCC server has failed and the standby server has taken over operation.
    Investigate the cause of the primary server failure, restore the primary server, and perform a manual switchback after confirming stability.
    Event ID: 1000006
    OPC server connection error. The WinCC OPC DA or OPC UA server cannot be reached by the configured OPC client.
    Verify OPC server is running, check DCOM settings for OPC DA, confirm firewall rules allow OPC UA port (default 4840), and re-test the OPC connection.
    Event ID: 1000007
    Alarm logging overflow. The alarm archive has reached its configured maximum size and new alarms cannot be stored.
    Increase the maximum archive size in WinCC Alarm Logging settings, archive old data to an external location, or enable automatic segment management.

    Frequently Asked Questions

    How many PowerTags does the 6AV6372-2DF07-0JH0 license support?

    The exact PowerTag count is encoded in the part number suffix. The 6AV6372-2DF07-0JH0 is a WinCC V7 package; the specific tag count should be confirmed against the Siemens SIMATIC WinCC ordering data, as different suffixes correspond to different tag counts (e.g., 128, 512, 2048, or unlimited tags).

    Is this WinCC software compatible with SIMATIC S7-1500 PLCs?

    Yes, WinCC V7 supports communication with SIMATIC S7-1500 PLCs via Industrial Ethernet using the SIMATIC S7 channel driver. OPC UA connectivity is also available for S7-1500 controllers.

    Can WinCC 6AV6372-2DF07-0JH0 be used in a redundant server configuration?

    Yes, WinCC V7 supports redundant server configurations where a standby server automatically takes over if the active server fails, provided the appropriate redundancy license option is included.

    What database system does WinCC V7 use for archiving?

    WinCC V7 uses Microsoft SQL Server as its underlying database engine for process value archiving and alarm logging. SQL Server is installed automatically as part of the WinCC installation.

    Does this software support OPC UA communication?

    Yes, WinCC V7 includes an OPC UA server and client, allowing data exchange with third-party systems and controllers that support the OPC UA standard.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error

    Check whether the SIMATIC Automation License Manager (ALM) detects a valid license. Open ALM and verify the license count and validity for the installed WinCC version.

    Insert the correct USB license dongle or transfer the license using the Automation License Manager. Ensure the license matches the WinCC version and PowerTag count configured in the project.

    No data displayed on HMI screens; all tags show error status

    Check the WinCC channel diagnostics in WinCC Explorer under the communication channel. Verify the PLC IP address or PROFIBUS address is correctly configured and that the PLC is reachable from the WinCC PC.

    Correct the channel configuration, verify network connectivity using ping or PROFIBUS diagnostics tools, and restart the WinCC channel driver. Ensure the PLC program is running and the data blocks referenced by WinCC tags exist.

    Historical trend data is missing or archive gaps are present

    Check the SQL Server service status in Windows Services. Review the WinCC Tag Logging error log for database write errors. Verify available disk space on the archive partition.

    Restart the SQL Server service if stopped, free disk space if the drive is full, and run the WinCC Database Repair Tool (WinCC Repair) to recover corrupted archive segments.

    WinCC client cannot connect to the WinCC server

    Verify that the WinCC server Runtime is active and that the client PC can reach the server via the network. Check Windows Firewall settings on the server for blocked WinCC ports.

    Configure Windows Firewall to allow WinCC communication ports, ensure both client and server are in the same Windows domain or workgroup with matching user credentials, and verify the server name is correctly entered in the client project.

    Alarms are not being logged or alarm archive is full

    Open WinCC Alarm Logging and check the configured maximum archive size and the current archive fill level. Review the WinCC diagnostic log for archive overflow events.

    Increase the maximum archive size or enable automatic segment swapping in Alarm Logging configuration. Archive and delete old alarm segments to free space, and verify the SQL Server has sufficient disk quota.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart