• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0JX0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6372-2DF07-0JX0 SIMATIC WinCC

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0JX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0JX0 is a WinCC (Windows Control Center) runtime software license belonging to Siemens' SIMATIC HMI software family. WinCC is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) software platform designed for process visualization and operator control on PC-based systems. This specific part number corresponds to a WinCC runtime package with a defined number of power tags, enabling process data visualization and control on standard industrial PCs or SIMATIC panel PCs.

    The WinCC runtime software provides a comprehensive set of features including process visualization, alarm management, trend display, reporting, and historical data archiving. It supports a wide range of communication interfaces and drivers, including PROFIBUS, PROFINET, MPI, and OPC UA/DA, enabling connectivity to SIMATIC S7 PLCs as well as third-party controllers. The software includes a configurable scripting environment (VBScript and C-Script), multi-user client-server architecture support, and integration with the SIMATIC engineering framework. Redundancy options and web client access are also supported within the WinCC platform.

    WinCC runtime software is widely deployed in process industries such as chemical, pharmaceutical, water and wastewater treatment, food and beverage, and energy management. It is also used extensively in discrete manufacturing environments for machine monitoring, production data acquisition, and operator interface applications. Its compatibility with the broader Siemens TIA Portal and SIMATIC ecosystem makes it a standard choice for facilities already operating Siemens automation infrastructure.

    Technical Specifications

    Software Type SCADA / HMI Runtime Software
    Series / Product Family SIMATIC WinCC
    Operating System Compatibility Windows (32/64-bit, industrial PC or SIMATIC panel PC)
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC UA, OPC DA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC
    Scripting Support VBScript, C-Script
    Architecture Single-user and client-server multi-user configurations
    Archiving Process value archiving, alarm archiving with SQL database support
    Alarm Management Integrated alarm system with acknowledgement, filtering, and logging
    Trend Display Online and historical trend visualization
    Redundancy Supported (server redundancy option)
    Web Access Supported via WinCC Web Navigator (optional add-on)
    Certifications CE, cULus
    Integration TIA Portal compatible, SIMATIC IT and MES integration capable

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC runtime startup error — the runtime could not be initialized, often due to licensing issues or corrupted project data.
    Verify that the software license (Automation License Manager) is correctly installed and active. Check the WinCC diagnostic log for detailed error information and repair or restore the project if corrupted.
    Event ID: 1000008
    Connection to PLC lost — the communication channel between WinCC and the configured PLC has been interrupted.
    Check network cabling and PROFIBUS/PROFINET connections. Verify PLC is powered and running. Confirm communication driver settings and IP/MPI address configuration in WinCC Channel Manager.
    Event ID: 1000022
    Tag logging error — process value archiving has failed or stopped writing to the database.
    Check available disk space on the archive drive. Verify SQL Server service is running. Review archive configuration and restart the WinCC Tag Logging service if necessary.
    Event ID: 1000040
    Alarm logging failure — alarm events are not being recorded to the alarm archive.
    Ensure the SQL Server instance used by WinCC is operational. Check disk space and database size limits. Restart the WinCC Alarm Logging runtime component and verify database connection settings.
    Event ID: 1000051
    License not found or invalid — WinCC runtime cannot find a valid license for the configured number of power tags.
    Open the Siemens Automation License Manager and verify the correct WinCC runtime license is present and not expired. Transfer or repair the license as required.
    Event ID: 1000065
    Script runtime error — a VBScript or C-Script action has encountered an execution error during runtime.
    Review the WinCC diagnostic log for the specific script name and line number. Correct the script logic in WinCC Graphics Designer or Global Script editor and restart the runtime.
    Event ID: 1000080
    OPC server communication error — WinCC OPC client cannot connect to the configured OPC server.
    Verify the OPC server is running and accessible on the network. Check DCOM security settings on both client and server machines. Confirm OPC server address and item configuration in WinCC.

    Frequently Asked Questions

    What is the power tag limit for the 6AV6372-2DF07-0JX0 WinCC runtime license?

    The 6AV6372-2DF07-0JX0 corresponds to a WinCC runtime license with 65,536 power tags, suitable for large-scale process visualization projects requiring high tag counts.

    Is WinCC 6AV6372-2DF07-0JX0 compatible with SIMATIC S7-1500 PLCs?

    Yes, WinCC supports communication with SIMATIC S7-1500 PLCs via PROFINET and OPC UA. The appropriate communication driver must be configured within the WinCC project.

    Can this WinCC runtime be used in a multi-user client-server configuration?

    Yes, WinCC supports client-server architectures where multiple WinCC clients can connect to a central WinCC server. Additional client licenses may be required depending on the number of connected clients.

    Does this software require a dedicated hardware key (dongle) for licensing?

    WinCC licensing is managed through the Siemens Automation License Manager (ALM) software. Licenses can be stored on a USB dongle or transferred to the hard drive of the target PC.

    Is TIA Portal required to configure WinCC 6AV6372-2DF07-0JX0?

    No, this WinCC runtime is part of the classic WinCC platform and is configured using the standalone WinCC Configuration Studio, not TIA Portal. TIA Portal is used for WinCC Comfort/Advanced panel projects, not classic PC-based WinCC.

    Troubleshooting

    WinCC runtime fails to start and displays a licensing error

    Open the Siemens Automation License Manager and check whether a valid WinCC runtime license is present on the local machine or connected USB dongle. Look for expired or missing licenses.

    Transfer a valid WinCC runtime license to the target PC using the Automation License Manager. If the license is on a dongle, ensure the dongle is connected before starting the runtime. Contact Siemens for license repair if the license is corrupted.

    Process tags show no values or display connection errors in WinCC runtime

    Check the WinCC Channel Manager for communication driver status. Verify the PLC IP address or MPI/PROFIBUS address settings. Use diagnostic tools such as SIMATIC NET or a ping test to confirm network connectivity to the PLC.

    Correct the communication channel configuration in WinCC. Ensure the PLC is powered and in RUN mode. Verify firewall settings are not blocking the communication port. Restart the WinCC communication driver if necessary.

    Historical trend data or alarm archive is not being recorded

    Check whether the SQL Server service (used by WinCC for archiving) is running via Windows Services. Verify available disk space on the archive partition. Review the WinCC diagnostic log for database connection errors.

    Restart the SQL Server service if it has stopped. Free up disk space or redirect archives to a larger storage volume. Verify database size limits have not been reached and adjust archive settings in WinCC Tag Logging or Alarm Logging configuration.

    WinCC graphics display is slow or unresponsive during runtime

    Monitor CPU and RAM usage on the PC during runtime. Check the number of active tags and update cycles configured. Identify any scripts running at high frequency that may be consuming excessive processing resources.

    Optimize tag update cycles by increasing the cycle time for non-critical tags. Review and optimize VBScript or C-Script actions to reduce execution frequency. Upgrade PC hardware (RAM, CPU) if system resources are consistently at capacity.

    WinCC client cannot connect to the WinCC server in a multi-user setup

    Verify network connectivity between client and server PCs. Check that the WinCC server runtime is active and that the correct server name or IP address is configured on the client. Review Windows firewall and DCOM settings on both machines.

    Ensure DCOM is correctly configured on both the server and client machines, with appropriate permissions granted to the WinCC user account. Add firewall exceptions for WinCC communication ports. Verify the WinCC server project is in runtime mode before attempting client connection.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart