Siemens 6AV6372-2DF07-1AH0 SIMATIC WinCC
€ 1.995,00
The Siemens 6AV6372-2DF07-1AH0 is a WinCC (Windows Control Center) runtime software license belonging to Siemens' SIMATIC HMI software family. WinCC is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) software platform designed for process visualization and operator control on PC-based systems. This specific part number corresponds to a WinCC runtime package with a defined tag/variable count, intended for use on standard industrial PCs or SIMATIC panel PCs running Microsoft Windows.
The WinCC runtime software provides a comprehensive set of features including process visualization, alarm management, trend display, reporting, and historical data archiving. It supports a wide range of communication interfaces and drivers, enabling connectivity to SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI, as well as third-party controllers via OPC DA/UA. The software includes a configurable graphics system, scripting support via VBScript and C-Script, and integration with the SIMATIC WinCC engineering environment for project configuration.
WinCC runtime software is widely deployed in manufacturing, process industries, energy management, water treatment, and building automation applications where centralized PC-based visualization and data acquisition are required. Its scalability from small single-station installations to large distributed multi-client/server architectures makes it suitable for both standalone machine-level HMI and plant-wide SCADA systems. Industries such as automotive, chemical, food and beverage, and pharmaceuticals commonly use WinCC for process monitoring and control.
Technical Specifications
| Software Type | SCADA / HMI Runtime Software |
|---|---|
| Product Family | SIMATIC WinCC |
| Platform | PC-based (Microsoft Windows) |
| Communication Interfaces | PROFIBUS, PROFINET, MPI, OPC DA, OPC UA |
| PLC Compatibility | SIMATIC S7-300, S7-400, S7-1200, S7-1500, third-party via OPC |
| Scripting Support | VBScript, C-Script |
| Architecture | Single-station or client/server |
| Operating System | Microsoft Windows (industrial PC or SIMATIC Panel PC) |
| Engineering Tool | SIMATIC WinCC Configuration Studio |
| Certifications | CE |
| License Type | Runtime license (tag-count based) |
Common Error Codes & System Events
- Event ID: 1000000
- WinCC runtime startup failure. The runtime system could not be initialized correctly.
Check Windows event log for details. Verify that all WinCC components are correctly installed and that the license (dongle or software license) is present and valid. - Event ID: 112000
- Communication error to PLC. The configured connection to the controller cannot be established or has been lost.
Verify network cabling and PROFIBUS/PROFINET configuration. Check PLC is powered and running. Confirm correct IP address or MPI address is configured in WinCC channel settings. - Event ID: 1001000
- License not found or invalid. WinCC runtime cannot find a valid license for the configured tag count.
Insert the correct USB license dongle or verify the software license is activated via Siemens Automation License Manager (ALM). Ensure the license covers the required number of power tags. - Event ID: 2501000
- Archive server connection failure. The WinCC process data archive cannot be accessed.
Check that the SQL Server (Microsoft SQL Server used by WinCC) service is running. Verify archive path configuration and available disk space. - Event ID: 1004000
- Tag read/write error. A configured process variable cannot be read from or written to the connected controller.
Verify the tag address configuration in WinCC Tag Management. Check PLC data block or memory area exists and is accessible. Review channel diagnostics in WinCC Explorer. - Event ID: 3000000
- Alarm logging error. The alarm system could not log an incoming alarm to the archive.
Check SQL Server service status and available disk space. Verify alarm logging configuration and that the archive database is not corrupted. - Event ID: 1100000
- Graphics runtime error. A picture or graphic object could not be loaded or rendered correctly.
Verify that all referenced picture files exist in the WinCC project directory. Re-compile the project in WinCC Configuration Studio and restart runtime.
Frequently Asked Questions
What is the tag/power tag count supported by the 6AV6372-2DF07-1AH0 license?
The 6AV6372-2DF07-1AH0 is a WinCC runtime license; the specific tag count is encoded in the part number variant. This part number corresponds to a 100,000 power tag runtime license. Confirm the exact count with the Siemens order documentation supplied with the license.
Which PLCs and controllers can WinCC communicate with using this software?
WinCC supports native communication with Siemens SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via PROFIBUS, PROFINET, and MPI. Third-party controllers can be integrated using OPC DA or OPC UA interfaces.
Is a hardware dongle required to run this WinCC runtime license?
WinCC licenses can be delivered as a USB hardware dongle (SIMATIC Automation License Manager key) or as a software-based license managed through the Siemens Automation License Manager (ALM). The delivery format depends on the specific order configuration.
Can this WinCC runtime be used in a client/server architecture?
Yes, WinCC supports single-station, multi-station, and client/server architectures. A WinCC server license is required for server functionality, and additional client licenses are needed for each connected WinCC client workstation.
What operating systems are supported by this WinCC runtime version?
WinCC runtime is supported on Microsoft Windows operating systems as specified in the Siemens compatibility matrix for the installed WinCC version. Industrial-grade Windows 10 and Windows Server editions are typically supported; refer to the Siemens SIMATIC WinCC readme for the exact version compatibility.
Troubleshooting
WinCC runtime fails to start and displays a license error on launch
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC runtime license is present and not expired or transferred. Verify the USB dongle is connected if a hardware license is used.
Insert the correct USB license dongle or use ALM to transfer a valid software license to the local machine. Ensure the license covers the required power tag count for the project.
No communication to PLC; all tags show error status in WinCC runtime
Check the WinCC channel diagnostics in WinCC Explorer under the communication channel. Verify the network connection (ping the PLC IP address) and confirm the PLC is in RUN mode.
Correct the IP address, MPI address, or PROFIBUS station address in the WinCC channel configuration. Restore network connectivity and restart the WinCC channel driver. Reload the runtime if necessary.
WinCC runtime crashes or freezes intermittently during operation
Review the Windows Event Viewer and the WinCC diagnostic log files located in the WinCC project directory for error entries. Check system resource usage (CPU, RAM, disk I/O) using Windows Task Manager.
Ensure the PC meets the minimum hardware requirements for the installed WinCC version and tag count. Disable unnecessary background applications. Apply the latest WinCC service pack and Windows updates. Check for SQL Server performance issues affecting archiving.
Historical trend data or alarm archives are not being recorded
Verify that the Microsoft SQL Server service used by WinCC is running in Windows Services. Check available disk space on the archive drive and review WinCC archive configuration settings.
Restart the SQL Server service if stopped. Free up disk space or redirect archives to a drive with sufficient capacity. Re-check the archive configuration in WinCC Tag Logging and Alarm Logging editors and reactivate the project.
WinCC project pictures do not display correctly or show missing objects after migration
Compare the WinCC version used to create the project with the currently installed runtime version. Check for missing or incompatible ActiveX controls or custom scripts referenced in the project.
Recompile the entire project in the WinCC Configuration Studio matching the runtime version. Register any missing ActiveX components. If migrating from an older WinCC version, use the WinCC project migration tool and review the migration log for unresolved items.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page