Siemens 6AV6372-2DF07-1AH3 SIMATIC WinCC flexible
€ 1.466,00
The Siemens 6AV6372-2DF07-1AH3 is a software license for SIMATIC WinCC flexible 2007, Siemens' scalable HMI engineering software platform designed for configuring and commissioning operator panels and visualization systems within the SIMATIC automation environment. This product belongs to the WinCC flexible product family, which serves as the engineering tool for the full range of SIMATIC HMI panels including the OP, TP, MP, and Mobile Panel series. It provides a comprehensive development environment for creating HMI projects ranging from simple single-panel applications to complex multi-panel installations.
WinCC flexible 2007 offers a tag-based licensing model and supports a wide range of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs as well as third-party controllers via standard protocols such as PROFIBUS, MPI, and Ethernet. The software includes an integrated project wizard, library management, faceplates, and script support using VBScript for advanced functionality. It supports multilingual project engineering with Unicode compliance, allowing projects to be configured in and switched between multiple languages at runtime. The engineering environment runs on standard Windows-based PCs and supports simulation of HMI projects without requiring physical hardware.
WinCC flexible 2007 is used across a broad range of industrial sectors including automotive manufacturing, food and beverage processing, pharmaceutical production, and machine building. It is the standard engineering tool for OEMs and system integrators who develop machine-level HMI solutions using Siemens SIMATIC panels. The software is particularly suited to applications requiring standardized panel configurations, project templates, and centralized management of multiple HMI devices across a production line or facility.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| License Type | Single-user software license |
| Compatible HMI Panels | SIMATIC OP, TP, MP, Mobile Panel series |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Protocols | PROFIBUS, MPI, Industrial Ethernet |
| Scripting Support | VBScript |
| Language Support | Multilingual, Unicode compliant |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Simulation | Integrated runtime simulator included |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes and System Events
- Event ID: 1000
- Project configuration error detected during compilation. One or more tags or connections are incorrectly configured.
Open the project in WinCC flexible, review the output window for specific compilation errors, correct misconfigured tags or communication connections, and recompile the project. - Event ID: 2001
- Communication connection to the PLC cannot be established during simulation or runtime transfer.
Verify the PLC address settings in the connection editor, check that the correct communication driver is selected, and confirm network or MPI/PROFIBUS cable connectivity. - Event ID: 3010
- License not found or license is invalid. The software cannot start in licensed mode.
Check that the hardware dongle or software license key is correctly installed. Use the Automation License Manager to verify license status and re-activate if necessary. - Event ID: 4005
- Project transfer to HMI panel failed. The panel is not reachable or the transfer settings are incorrect.
Confirm the panel IP address or MPI address in the transfer settings, ensure the panel is in transfer mode, and check the physical connection between the engineering PC and the panel. - Event ID: 5002
- Runtime simulation terminated unexpectedly due to a script error in a VBScript function.
Review the VBScript code in the affected screen or global script, check for syntax errors or unhandled exceptions, and re-test the simulation after corrections. - Event ID: 6001
- Incompatible project version detected. The project was created with a newer or older version of WinCC flexible.
Open the project migration wizard in WinCC flexible to convert the project to the correct version, or install the appropriate version of WinCC flexible that matches the project version. - Event ID: 7003
- Tag limit exceeded for the current license edition. More tags are configured than the license permits.
Reduce the number of configured tags to within the licensed limit, or upgrade the WinCC flexible license to a higher tag count edition.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2007?
WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, Mobile Panel 177, and other panels in the OP, TP, and MP series. It does not support the newer Comfort Panel series, which requires WinCC flexible 2008 or TIA Portal.
Is a hardware dongle required to run WinCC flexible 2007?
WinCC flexible 2007 uses Siemens Automation License Manager for license management. Depending on the license variant, it may use a USB hardware dongle or a software-based license key installed on the engineering PC.
Can WinCC flexible 2007 projects be migrated to TIA Portal?
Yes, WinCC flexible projects can be migrated to TIA Portal using the integrated migration tool available in TIA Portal. However, some features and scripts may require manual rework after migration due to differences in the engineering environments.
Does WinCC flexible 2007 support communication with third-party PLCs?
Yes, WinCC flexible 2007 includes communication drivers for a range of third-party controllers in addition to SIMATIC PLCs, supporting protocols such as Modbus, Allen-Bradley DF1, and others depending on the installed driver package.
What Windows operating systems are compatible with WinCC flexible 2007?
WinCC flexible 2007 is compatible with Windows XP Professional, Windows Vista, and Windows 7 (32-bit editions). It is not officially supported on Windows 10 or later operating systems.
Troubleshooting
Software fails to start and displays a license error message
Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2007 is present and not expired or transferred away.
Re-insert the USB license dongle if applicable, or use the Automation License Manager to transfer a valid license back to the engineering PC. Contact Siemens license support if the license cannot be recovered.
Project compilation fails with multiple tag or connection errors
Review the output and error windows in WinCC flexible after attempting compilation. Identify which tags reference missing or incorrectly named PLC variables or connections.
Correct all invalid tag addresses and connection references in the project editor. Ensure PLC variable names and data types match the configured HMI tags exactly, then recompile the project.
Transfer of project to HMI panel times out or fails
Check the transfer settings in WinCC flexible for the correct panel IP address or MPI/PROFIBUS address. Verify the panel is set to transfer mode and the physical cable or network connection is active.
Set the correct communication parameters in the transfer dialog, place the panel in transfer mode via its control panel settings, and retry the transfer. Replace the communication cable if connectivity issues persist.
Runtime simulation crashes when navigating to a specific screen
Isolate the problematic screen by navigating to it directly in simulation. Check for VBScript errors in the output window and identify any scripts attached to screen events or tags on that screen.
Review and correct any VBScript code on the affected screen. Remove or disable scripts one at a time to identify the faulty script, correct the logic or syntax error, and re-run the simulation.
Installed software does not recognize connected HMI panel during transfer
Verify that the correct communication driver for the panel interface (Ethernet, USB, or MPI) is installed on the engineering PC and that Windows device drivers for the communication adapter are properly installed.
Reinstall the communication driver from the WinCC flexible installation media, check Windows Device Manager for driver errors on the communication adapter, and confirm firewall settings are not blocking the transfer connection.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page