• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6372-2DF07-0HX4 SIMATIC WinCC flexible
    Awaiting product image

    Siemens 6AV6372-2DF07-0HX4 SIMATIC WinCC flexible

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6372-2DF07-0HX4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6372-2DF07-0HX4 is a software license for SIMATIC WinCC flexible 2007, Siemens' scalable HMI engineering software platform designed for configuring and commissioning operator panels and HMI systems within the SIMATIC automation environment. It belongs to the WinCC flexible product family, which serves as the engineering tool for the full range of SIMATIC HMI panels including the OP, TP, MP, and Mobile Panel series. The software enables engineers to create, simulate, and manage HMI projects for both standalone panel applications and networked SCADA-level installations.

    WinCC flexible 2007 provides a comprehensive set of engineering tools including a graphical project editor, tag management, alarm and event logging, recipe management, and trend display configuration. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a runtime simulation function allowing offline testing of HMI projects without physical hardware, and supports multi-language project configuration for international deployments. The platform is built on a Windows-based architecture and integrates with the broader Siemens TIA (Totally Integrated Automation) engineering environment.

    SIMATIC WinCC flexible 2007 is widely used in manufacturing, process automation, machine building, and plant engineering applications where operator interface configuration is required across multiple panel types. It is particularly suited for OEMs and system integrators who need to develop and maintain HMI projects for a variety of SIMATIC panel hardware. Industries such as automotive, food and beverage, pharmaceutical, and water treatment commonly deploy this software as part of their SIMATIC-based control system engineering workflows.

    Technical Specifications

    Software Version WinCC flexible 2007
    Series/Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Compatible HMI Hardware SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7
    Simulation Integrated offline runtime simulation
    Language Support Multi-language project configuration
    Integration Compatible with STEP 7 and TIA Portal environment
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000001
    Communication error between engineering software and connected HMI panel during project download.
    Check the communication cable and interface settings. Verify the correct COM port or network address is configured in the project properties and retry the transfer.
    Event ID: 1000010
    Project compilation error due to invalid or missing tag references in the HMI configuration.
    Open the project in the WinCC flexible editor, run the consistency check, and resolve all reported tag or connection errors before recompiling.
    Event ID: 1000020
    License not found or license key invalid on the engineering PC.
    Verify the software license dongle (SIMATIC Automation License Manager) is correctly installed and recognized. Re-activate or re-seat the license key as required.
    Event ID: 1000030
    Runtime simulation failed to start due to missing runtime components.
    Reinstall the WinCC flexible runtime simulation component via the software installation media and ensure all prerequisites are met.
    Event ID: 1000040
    Project migration error when opening a project created in an older version of WinCC flexible.
    Use the integrated migration wizard to convert the project. Back up the original project before migration and resolve any reported incompatibilities manually.
    Event ID: 1000050
    Insufficient system resources; software performance degraded or unresponsive during project editing.
    Close unnecessary background applications, ensure the PC meets minimum RAM and CPU requirements, and consider increasing virtual memory allocation.
    Event ID: 1000060
    Panel transfer aborted due to version mismatch between engineering software and panel firmware.
    Update the HMI panel firmware to a version compatible with WinCC flexible 2007, or use the appropriate software version matching the panel firmware.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007 (6AV6372-2DF07-0HX4)?

    WinCC flexible 2007 supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel 177 series, among others. Compatibility depends on the specific panel firmware version.

    Can WinCC flexible 2007 communicate with S7-1200 PLCs?

    Yes, WinCC flexible 2007 supports communication with SIMATIC S7-1200 PLCs via Industrial Ethernet using the TCP/IP protocol. Appropriate communication drivers must be configured within the project.

    Is a hardware dongle required to run WinCC flexible 2007?

    Yes, WinCC flexible requires a valid license managed through the Siemens Automation License Manager (ALM). The license may be stored on a USB dongle or transferred to the engineering PC's hard drive.

    Can projects created in WinCC flexible 2007 be migrated to TIA Portal WinCC?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, some manual rework may be required depending on the complexity of the original project and the target TIA Portal version.

    What operating systems are compatible with WinCC flexible 2007?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later operating systems.

    Troubleshooting

    Software fails to install or installation aborts partway through

    Check the Windows event log for installation errors. Verify that the PC meets the minimum hardware requirements and that no conflicting software or previous WinCC flexible versions are partially installed.

    Uninstall any remnants of previous installations using the Siemens Product Uninstall tool, ensure .NET Framework and other prerequisites are installed, then re-run the installation as an administrator.

    Project download to HMI panel fails with a communication error

    Verify the physical connection between the PC and the HMI panel (USB, MPI, or Ethernet cable). Check that the correct transfer channel and panel IP address or MPI address are configured in the transfer settings.

    Reconfigure the transfer settings in WinCC flexible to match the panel's communication parameters. Test the connection using the panel's built-in transfer mode and replace the communication cable if necessary.

    Consistency check reports numerous errors after opening an existing project

    The project may have been created in a different version of WinCC flexible or contains references to tags, screens, or connections that are no longer valid.

    Run the migration wizard if the project originates from an older version. Manually resolve tag and connection errors identified in the consistency check output before attempting to compile or download the project.

    Runtime simulation crashes or does not reflect project changes

    The simulation runtime component may be outdated or corrupted, or the project has not been saved and recompiled after recent changes.

    Save and recompile the project before launching the simulation. If the issue persists, repair the WinCC flexible installation via the setup program to restore the simulation runtime components.

    License Manager reports no valid license found after PC replacement or hard drive change

    The software license may have been bound to the previous hardware fingerprint or stored on a dongle that is not connected.

    Connect the original license dongle, or use the Siemens Automation License Manager to transfer the license back from the old storage medium. Contact Siemens support for license recovery if the original storage medium is unavailable.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart