• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-2BP17-5AJ0 SIMATIC WinCC
    Awaiting product image

    Siemens 6AV6371-2BP17-5AJ0 SIMATIC WinCC

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6371-2BP17-5AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-2BP17-5AJ0 is a WinCC (Windows Control Center) SCADA/HMI software package belonging to the SIMATIC HMI product family from Siemens. This part number corresponds to a WinCC Runtime or configuration software license, designed to provide supervisory control and data acquisition capabilities on PC-based HMI systems. It serves as the central software platform for visualizing and operating industrial processes on standard PC hardware running Windows operating systems.

    WinCC 6AV6371-2BP17-5AJ0 offers a comprehensive set of features including tag-based licensing for scalable process visualization, integrated alarm and event management, historical data logging, and trend displays. The software supports a wide range of communication interfaces including PROFIBUS, PROFINET, MPI, and OPC (OPC DA/UA), enabling connectivity to SIMATIC S7 PLCs and third-party controllers. It provides a powerful scripting environment (VBScript and C-Script), multi-user project capability, and robust security management with user authentication and access control levels.

    This WinCC software is widely deployed in process industries such as chemical, pharmaceutical, food and beverage, water treatment, and power generation, as well as in discrete manufacturing environments. It is particularly suited for applications requiring centralized monitoring of large-scale plant operations, where reliable data archiving, reporting, and real-time visualization are critical. The PC-based platform allows integration with enterprise-level IT systems and databases such as Microsoft SQL Server for advanced data management.

    Technical Specifications

    Software Type SCADA / HMI Runtime & Configuration Software
    Platform PC-based (Windows OS)
    Product Family SIMATIC WinCC
    Communication Interfaces PROFIBUS, PROFINET, MPI, OPC DA, OPC UA
    PLC Compatibility SIMATIC S7-300, S7-400, S7-1200, S7-1500, and third-party via OPC
    Scripting Support VBScript, C-Script
    Database Microsoft SQL Server (integrated)
    Alarm Management Integrated alarm logging and event management
    Data Archiving Process value archiving with trend display
    Multi-User Support Yes, multi-user and multi-client architecture
    Security User authentication with role-based access control
    Certifications CE, cULus
    Operating System Microsoft Windows (Server/Professional editions)
    License Type Floating / single-station license (tag-based)

    Common Error Codes & System Events

    Event ID: 1000000
    WinCC Runtime startup failure. The runtime could not be initialized, often due to a missing or invalid license.
    Verify that a valid WinCC license is installed using the Siemens Automation License Manager (ALM). Ensure the license matches the configured tag count.
    Event ID: 1001
    Communication error to PLC. The configured channel driver cannot establish a connection to the target controller.
    Check network cabling and PROFIBUS/PROFINET configuration. Verify PLC IP address or MPI address settings in the WinCC channel configuration. Confirm the PLC is in RUN mode.
    Event ID: 10241
    Tag logging error. Process value archiving has failed or the archive database is unavailable.
    Check the SQL Server service is running. Verify available disk space and database integrity. Restart the WinCC Tag Logging service if necessary.
    Event ID: 10001
    License not found or license count exceeded. The number of configured power tags exceeds the licensed tag count.
    Check the installed license using Automation License Manager. Upgrade the license to a higher tag count or reduce the number of configured power tags in the project.
    Event ID: 112
    WinCC project database error. The project could not be opened due to a corrupt or inaccessible database.
    Run the WinCC project consistency check. Restore the project from a recent backup. If the database is corrupt, use SQL Server tools to attempt repair.
    Event ID: 10050
    Alarm logging system error. The alarm server could not write to the alarm archive.
    Check disk space and SQL Server availability. Restart the WinCC Alarm Logging runtime component. Verify alarm archive configuration in WinCC Explorer.
    Event ID: 10100
    OPC server connection failure. WinCC OPC DA or OPC UA client cannot connect to the configured OPC server.
    Verify OPC server is running and accessible on the network. Check DCOM settings for OPC DA connections. For OPC UA, verify endpoint URL, certificates, and firewall rules.
    Event ID: 10200
    User administration error. A user login attempt failed or the user archive is inaccessible.
    Verify user credentials and that the WinCC User Administrator is correctly configured. Check that the user archive database is accessible and not locked.

    Frequently Asked Questions

    What is the tag (power tag) limit for this WinCC license?

    The tag count for the 6AV6371-2BP17-5AJ0 license variant determines how many process variables can be connected in runtime. The specific power tag limit is encoded in the license key and must be verified using the Siemens Automation License Manager (ALM). Common WinCC license tiers include 128, 256, 1024, 8192, and 65536 power tags.

    Which PLCs and controllers are compatible with WinCC 6AV6371-2BP17-5AJ0?

    WinCC natively supports all SIMATIC S7 PLC families (S7-300, S7-400, S7-1200, S7-1500) via PROFIBUS, PROFINET, and MPI. Third-party controllers can be integrated using OPC DA or OPC UA interfaces, as well as a range of additional channel drivers available for Modbus, Allen-Bradley, and other protocols.

    Does this WinCC software support multi-user operation?

    Yes, WinCC supports a multi-user and multi-client architecture where multiple operator stations can connect to a central WinCC server. The number of client connections depends on the specific license configuration purchased.

    What operating system is required to run WinCC 6AV6371-2BP17-5AJ0?

    WinCC requires a compatible Microsoft Windows operating system, typically Windows 7 Professional/Ultimate (64-bit) or Windows Server 2008 R2 and later, depending on the WinCC version. Siemens publishes a compatibility list for each WinCC release specifying supported OS versions.

    Can WinCC be integrated with enterprise IT systems and databases?

    Yes, WinCC uses Microsoft SQL Server as its integrated database engine, enabling straightforward integration with enterprise IT systems. It also supports OPC UA for standardized data exchange and can interface with MES and ERP systems through its open API and scripting capabilities.

    Troubleshooting

    WinCC Runtime fails to start and displays a license error

    Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC license is present and not expired or transferred. Verify the license tag count matches or exceeds the number of power tags configured in the project.

    Install or transfer a valid WinCC license using ALM. If the license is on a USB dongle, ensure the dongle is connected. If the tag count is exceeded, either upgrade the license or reduce the number of configured power tags in the WinCC project.

    No communication between WinCC and the SIMATIC S7 PLC

    Check the channel driver configuration in WinCC Explorer for the correct PLC IP address, rack, and slot settings. Use the Siemens SIMATIC NET diagnostic tools or ping the PLC to verify network connectivity. Confirm the PLC is in RUN mode and not in STOP.

    Correct the connection parameters in the WinCC channel configuration. Verify PROFINET or PROFIBUS network cabling and switch/hub settings. Ensure the PC network adapter is correctly configured and that Windows Firewall is not blocking the SIMATIC communication ports.

    WinCC project database cannot be opened or is reported as corrupt

    Attempt to open the project in WinCC Explorer and note the exact error message. Run the WinCC consistency check tool. Check the Windows Event Viewer for SQL Server errors that may indicate database corruption or service failure.

    Restore the project from the most recent backup. If no backup is available, use SQL Server Management Studio to attempt a database repair. Ensure the SQL Server service (WINCC instance) is running and that the Windows user account has sufficient database permissions.

    Alarm logging stops recording alarms during runtime

    Check available disk space on the drive hosting the WinCC project and SQL Server data files. Open WinCC Alarm Logging and verify the archive configuration and segment settings. Review the WinCC diagnostic log for alarm logging service errors.

    Free up disk space or redirect archives to a larger volume. Restart the WinCC Alarm Logging runtime service. If archive segments are full, configure automatic segment management or increase the maximum archive size in the Alarm Logging editor.

    Trend displays show no historical data or gaps in process value archives

    Verify that the Tag Logging runtime service is active in WinCC Runtime. Check the archive configuration for the affected tags to confirm logging cycles and archive assignments are correct. Inspect SQL Server for errors related to the WinCC archive database.

    Restart the Tag Logging runtime service. Correct the archive configuration for affected tags if logging cycles are set to zero or tags are not assigned to an archive. Ensure SQL Server has sufficient resources (disk, memory) to handle the configured logging rate.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart