• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1DV08-0BX3 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1DV08-0BX3 WinCC flexible 2008

    € 133,25

    Reset
    Clear
    SKU: 6AV6371-1DV08-0BX3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1DV08-0BX3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible SCADA and HMI engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels including the OP, TP, MP, and Mobile Panel series. It is designed to run on standard engineering PCs and integrates tightly with the Siemens SIMATIC automation ecosystem.

    WinCC flexible 2008 offers a comprehensive set of tools for creating HMI visualizations, including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a simulation function that allows offline testing of HMI projects without physical hardware, and supports multi-language project engineering for international deployments.

    This software is used across a wide range of industrial sectors including manufacturing, automotive, food and beverage, water treatment, and process automation. It is the standard engineering tool for configuring Siemens operator panels deployed on machine-level HMI applications. The 2008 edition represents a mature release of the WinCC flexible platform, widely used for maintaining and extending existing SIMATIC HMI installations.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Compatible HMI Devices SIMATIC OP, TP, MP, Mobile Panel series
    Compatible PLCs SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Scripting Support VBScript
    Simulation Integrated offline project simulation
    Operating System Windows XP, Windows Vista, Windows 7
    Series/Product Family WinCC flexible
    Language Support Multi-language project engineering
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported

    Common Error Codes & System Events

    Error 1920
    Storage device not ready or inaccessible during project transfer
    Verify the target HMI device is powered on and connected. Check communication cable and interface settings in the project transfer dialog.
    Error 1925
    Connection to target device could not be established during download
    Confirm the correct communication interface is selected. Check IP address or MPI/PROFIBUS address settings and ensure no firewall is blocking the connection.
    Error 2557
    License for WinCC flexible not found or invalid
    Run the Automation License Manager to verify the license is correctly installed and activated. Re-install or transfer the license if necessary.
    Error 110
    Project compilation error due to inconsistent tag or screen configuration
    Review the validation output in the compiler log. Correct any missing tag references, duplicate names, or unsupported object configurations before recompiling.
    Error 4
    Runtime version mismatch between engineering project and target HMI panel
    Ensure the WinCC flexible runtime version installed on the HMI panel matches the version used in the engineering software. Update the panel runtime if required.
    Transfer Error: Incompatible Device
    Project was configured for a different HMI device type than the connected panel
    Open the project properties and verify the selected HMI device matches the physical target panel. Migrate the project to the correct device type if needed.
    Simulation Abort
    Offline simulation terminated unexpectedly due to script error or resource conflict
    Check VBScript code for runtime errors. Reduce the number of active simulated tags and ensure the engineering PC meets minimum system requirements.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the OP 77, TP 177, MP 277, MP 377, Mobile Panel 177, and other panels from the OP, TP, and MP series. It does not support the newer Comfort Panel series, which requires WinCC flexible 2008 SP3 or TIA Portal.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1500 PLCs?

    No, WinCC flexible 2008 does not natively support the S7-1500 PLC series. S7-1500 integration requires the TIA Portal engineering framework with WinCC (TIA Portal).

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required depending on the complexity of the project and the target device.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 supports Windows XP Professional, Windows Vista, and Windows 7 (32-bit and 64-bit editions). It is not officially supported on Windows 10 or later without compatibility workarounds.

    Does this license include WinCC flexible Runtime?

    The 6AV6371-1DV08-0BX3 is an engineering software license and does not include a PC-based WinCC flexible Runtime license. Runtime licenses for PC-based visualization are ordered separately.

    Troubleshooting

    Software fails to install or license is not recognized after installation

    Open the Siemens Automation License Manager and check whether the license key is listed and shows a valid status. Verify the license dongle or software license is present and not assigned to another machine.

    Transfer or re-activate the license using the Automation License Manager. If using a hardware dongle, ensure it is connected before launching the software. Reinstall the license if it shows as defective.

    Project cannot be transferred to the HMI panel and transfer dialog shows a connection error

    Check the physical connection between the engineering PC and the HMI panel. Verify the correct transfer interface (USB, Ethernet, or MPI/PROFIBUS) is selected in the transfer settings and that the panel is in transfer mode.

    Switch the HMI panel to transfer mode manually via the panel's start center. Confirm IP addresses or bus addresses match the project settings. Replace the communication cable if hardware faults are suspected.

    Compilation errors appear when building the HMI project

    Review the output window for specific error messages referencing tags, screens, or scripts. Common causes include missing PLC tag connections, duplicate object names, or use of functions not supported by the target device.

    Correct all flagged errors in the compiler output. Ensure all referenced PLC tags exist and are correctly typed. Remove or replace unsupported objects for the configured target HMI device.

    WinCC flexible 2008 crashes or becomes unstable on the engineering PC

    Check whether the PC meets the minimum system requirements for WinCC flexible 2008. Conflicts with other installed Siemens software versions or incompatible Windows updates can cause instability.

    Ensure the correct service pack for WinCC flexible 2008 is installed. Uninstall conflicting software versions and apply all recommended Siemens patches. Running the software on a dedicated engineering PC with a supported OS reduces instability.

    Offline simulation does not reflect PLC logic correctly

    The integrated simulation only simulates the HMI project locally and does not connect to a real or virtual PLC. Tag values must be driven manually or via the simulation table during offline testing.

    Use the simulation tag table to manually set tag values and verify screen behavior. For full system testing including PLC logic, connect to a physical or software-based S7 PLC using the appropriate communication interface.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart