Siemens 6AV6371-1DV18-0AX0 WinCC flexible 2008
€ 2.495,00
The Siemens 6AV6371-1DV18-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family used for configuring and commissioning HMI panels and visualization systems. This product belongs to the SIMATIC HMI software portfolio and serves as the primary engineering tool for creating operator interface projects on Siemens HMI hardware. The software is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2008 provides a comprehensive engineering environment for developing HMI applications, including screen editors, tag management, alarm logging, trend displays, and recipe management. The software supports a wide range of Siemens HMI hardware targets, including the SIMATIC Panels (TP, OP, MP series), Mobile Panels, and Comfort Panels. It offers integrated communication configuration for PROFIBUS, PROFINET, MPI, and other industrial protocols, and supports project migration from earlier WinCC flexible versions. The 2008 edition introduced enhanced scripting capabilities and improved project management tools.
WinCC flexible 2008 is used across a broad range of industrial sectors including automotive manufacturing, food and beverage processing, chemical plants, and machine building. It is the standard engineering tool for facilities that operate Siemens SIMATIC HMI panels and require a unified visualization and operator control solution. The software is particularly suited to OEMs and system integrators who develop standardized HMI projects for deployment across multiple machines or production lines.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Single-user engineering license |
| Compatible HMI Hardware | SIMATIC TP, OP, MP, Mobile Panel, Comfort Panel series |
| Communication Protocols | PROFIBUS, PROFINET, MPI, Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 (32/64-bit) |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Project Migration | Supports migration from WinCC flexible 2004/2005/2007 |
| Scripting Support | VBScript |
| Series/Product Family | SIMATIC WinCC flexible |
| Language Support | Multi-language project engineering |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Integrated recipe editor |
Common Error Codes & System Events
- Event ID: 1000
- License not found or invalid license key detected during software startup
Verify that the correct license is installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary. - Event ID: 1001
- Communication error between WinCC flexible engineering station and HMI panel during project download
Check the physical connection (USB, Ethernet, or MPI/PROFIBUS cable). Verify the correct communication interface and transfer settings are configured in the project. - Event ID: 1002
- Project compilation error due to inconsistent tag configuration or missing references
Open the project validator in WinCC flexible and resolve all reported tag or screen reference errors before recompiling. - Event ID: 1003
- Runtime version mismatch between the engineering software and the target HMI panel firmware
Update the HMI panel firmware to a version compatible with WinCC flexible 2008 using the ProSave tool or via the panel's update function. - Event ID: 1004
- Insufficient disk space or memory during project save or compilation
Free up disk space on the engineering PC, check that the project directory is accessible, and ensure the PC meets the minimum system requirements for WinCC flexible 2008. - Event ID: 1005
- Migration error when opening a project created in an earlier version of WinCC flexible
Use the integrated migration wizard and review the migration log for unsupported objects or deprecated functions. Manually update affected screens or tags as indicated. - Event ID: 1006
- Automation License Manager (ALM) service not running or inaccessible
Start the ALM service via Windows Services (services.msc). Reinstall the Automation License Manager if the service cannot be started.
Frequently Asked Questions
Which HMI panels are supported as targets in WinCC flexible 2008?
WinCC flexible 2008 supports SIMATIC TP, OP, MP, Mobile Panel, and Comfort Panel series as engineering targets. Panels from the Micro Panel range are also supported depending on the installed edition.
Is WinCC flexible 2008 compatible with Windows 10?
WinCC flexible 2008 was not officially qualified for Windows 10. It is designed for Windows XP, Windows Vista, and Windows 7. For Windows 10 compatibility, Siemens recommends migrating to TIA Portal with WinCC.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. Some manual rework may be required for complex projects with VBScript or unsupported objects.
What communication interfaces can be configured for HMI-to-PLC communication?
WinCC flexible 2008 supports configuration of PROFIBUS DP, MPI, PROFINET, and Ethernet-based connections to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC.
Does this license include WinCC flexible Runtime?
The engineering license (6AV6371-1DV18-0AX0) covers the engineering software only. Runtime licenses for PC-based visualization are separate products and must be ordered independently.
Troubleshooting
Software fails to start and displays a license error message
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2008 license is present and assigned to the local machine.
Transfer or reinstall the license using the ALM tool. If the license is stored on a USB dongle, ensure the dongle is connected before launching the software.
Project download to HMI panel fails with a connection timeout
Verify the physical cable connection and check the transfer settings in WinCC flexible under Transfer > Transfer Settings. Confirm the panel is in transfer mode.
Switch the HMI panel to transfer mode manually via the Start Center or Control Panel on the device. Ensure the correct interface (USB, Ethernet, or MPI) and IP address or bus address are configured in the engineering software.
Compilation errors appear when building the project
Run the integrated project validator (Project > Compile > Check Consistency) to identify all errors. Common causes include undefined tags, missing screen references, or incompatible object properties.
Resolve each error listed in the output window by correcting tag names, re-linking screen navigation objects, or removing unsupported functions. Recompile after each correction.
Older project cannot be opened and migration wizard reports errors
Review the migration log file generated by WinCC flexible 2008 to identify which objects or functions are not supported in the target version.
Manually recreate unsupported objects in the new project environment. Remove deprecated VBScript functions or replace them with supported equivalents before completing the migration.
HMI panel shows runtime version mismatch after project transfer
Compare the WinCC flexible Runtime version installed on the HMI panel with the version used during engineering. This information is visible in the panel's System dialog or Start Center.
Update the HMI panel firmware to the correct version using the Siemens ProSave tool via USB or Ethernet. Ensure the firmware version matches the WinCC flexible 2008 engineering software version.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page