• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6371-1DV08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6371-1DV08-0AX0 WinCC flexible 2008

    € 672,77

    Reset
    Clear
    SKU: 6AV6371-1DV08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6371-1DV08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' SIMATIC HMI software portfolio. WinCC flexible 2008 is an engineering software platform used to configure and program SIMATIC HMI panels, including the OP, TP, MP, and Mobile Panel series. It serves as the central tool for creating visualization projects, screen layouts, and communication configurations for human-machine interface devices.

    WinCC flexible 2008 provides a comprehensive engineering environment with a tag-based data model, script support via VBScript, and integrated alarm, trend, and recipe management. The software supports a wide range of communication drivers enabling connectivity to SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC and other standard protocols. It includes simulation capabilities allowing projects to be tested on a PC without physical hardware, and supports multi-language project engineering for international deployments.

    WinCC flexible 2008 is used across a broad range of industries including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is particularly suited for machine-level HMI applications where SIMATIC panels are integrated into automated production lines, packaging machines, and process control systems. The software is compatible with the full range of SIMATIC HMI hardware available at the time of its release, making it a standard engineering tool for system integrators and OEMs working within the Siemens automation ecosystem.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user license
    Compatible HMI Hardware SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200, third-party via OPC
    Scripting Support VBScript
    Communication Protocols PROFIBUS, MPI, PROFINET, OPC, Ethernet
    Operating System Windows XP, Windows Vista, Windows 7
    Simulation Integrated PC-based project simulation
    Language Support Multi-language project engineering
    Series/Product Family SIMATIC WinCC flexible
    Alarm Management Integrated alarm logging and display
    Recipe Management Integrated recipe editor and runtime support

    Common Error Codes and Software Events

    Error 1920
    License not found or license server unreachable during software startup.
    Verify that the license key (dongle or software license) is correctly installed using the Siemens Automation License Manager. Reinstall or transfer the license if necessary.
    Error 1935
    Installation error related to missing or corrupt Microsoft .NET Framework or Visual C++ runtime components.
    Ensure all required Microsoft prerequisites (.NET Framework, Visual C++ redistributables) are installed before running the WinCC flexible 2008 setup.
    Communication Error
    No connection established between WinCC flexible engineering station and the target HMI panel during download.
    Check the communication cable and interface settings (MPI, PROFIBUS, or Ethernet). Verify the correct transfer channel is selected in the project settings and that the panel is in transfer mode.
    Compile Error
    Project compilation fails due to inconsistent tag references or missing screen objects.
    Review the output window for specific object or tag references causing the error. Correct invalid tag connections or missing resources and recompile the project.
    Download Error
    Project download to HMI panel is interrupted or fails to complete.
    Ensure the panel has sufficient free memory for the project. Check that the WinCC flexible runtime version on the panel matches the project version. Perform a panel reset if necessary before re-downloading.
    Simulation Abort
    Integrated simulation terminates unexpectedly during project testing.
    Check for unsupported functions or script errors in the project. Review VBScript code for runtime exceptions and ensure the PC meets minimum system requirements for simulation.
    Version Conflict
    Project was created with a different version of WinCC flexible and cannot be opened directly.
    Use the project migration wizard within WinCC flexible 2008 to convert the project from an older version. Back up the original project before migration.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels available at the time of release, including the OP 77, TP 177, MP 277, MP 377, and Mobile Panel 177 series, among others.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues may arise when attempting installation on newer operating systems.

    Can WinCC flexible 2008 communicate with non-Siemens PLCs?

    Yes, WinCC flexible 2008 supports OPC DA communication, allowing connectivity to third-party PLCs and automation systems that provide an OPC server interface.

    Does this license include WinCC flexible Runtime?

    The 6AV6371-1DV08-0AX0 is an engineering software license. Runtime licenses for HMI panels are separate and are typically pre-installed on the SIMATIC HMI hardware or ordered as separate line items.

    Can projects created in WinCC flexible 2008 be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects, though some manual rework may be required depending on the complexity of the project and the target panel type.

    Troubleshooting

    WinCC flexible 2008 fails to start and displays a license error

    Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2008 is present and assigned to the local machine.

    Transfer or reinstall the software license using the Automation License Manager. If using a USB dongle, ensure it is connected and recognized by the operating system before launching the software.

    Project download to HMI panel fails with a connection timeout

    Verify the physical connection between the engineering PC and the HMI panel. Check that the correct communication interface (MPI, PROFIBUS, or Ethernet) and transfer settings are configured in both the project and the panel's control panel.

    Set the HMI panel to transfer mode manually, confirm the correct COM port or network adapter is selected in WinCC flexible, and retry the download. Replace the communication cable if hardware faults are suspected.

    Compilation errors appear when building the project

    Review the compiler output window for specific error messages referencing tags, screens, or scripts. Identify any broken tag links or references to deleted objects.

    Correct all invalid tag references, remove or repair broken screen object links, and ensure all VBScripts are free of syntax errors before recompiling.

    Simulation does not reflect the correct screen behavior

    Check whether the simulation is using the correct project version and that all tags used in the simulation are properly configured with initial values or simulated data sources.

    Configure simulation tags with appropriate test values using the integrated tag simulation table. Ensure no external PLC connection is required for the screens under test.

    WinCC flexible 2008 installation fails on the engineering PC

    Check the Windows Event Viewer for installation error codes. Confirm that all prerequisite software components, including the correct .NET Framework version and Visual C++ runtimes, are installed.

    Install all required Microsoft prerequisites as listed in the WinCC flexible 2008 release notes, then re-run the setup as an administrator. Disable antivirus software temporarily during installation if conflicts are detected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart