€ 939,56
The Siemens 6AV6355-1CA47-7ES1 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels series. It is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface tasks. This unit provides a text-based display with function keys for direct process control and monitoring without the need for a touchscreen interface.
The OP 77B features a 4-line STN LCD display capable of showing alphanumeric text and basic graphics, with a resolution of 160 x 64 pixels. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports recipe management, alarm logging, and trend display functions. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77B is widely used in manufacturing, packaging, and process automation applications where a cost-effective, robust operator interface is required at the machine level. Its compatibility with the SIMATIC S7 PLC family makes it a practical choice for retrofitting or extending existing Siemens automation systems. The panel is suited for environments where a simple, reliable text-based interface is preferred over more complex graphical touchscreen solutions.
Technical Specifications
| Display Type | STN LCD |
|---|---|
| Display Resolution | 160 x 64 pixels |
| Display Lines | 4 lines of text |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 5 W |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 77B |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The connection to the configured controller cannot be established.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI configuration in WinCC flexible. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect communication cables for damage or loose connectors. Confirm the PLC is powered and running. Re-establish the connection and check for network address conflicts. - Event ID: 20000
- Configuration error detected. The project loaded on the panel is incompatible or corrupt.
Reload the project from WinCC flexible to the panel. Ensure the WinCC flexible version used is compatible with the OP 77B firmware version. - Event ID: 40000
- System memory low. Insufficient memory available for the current operation.
Reduce the number of active alarms or recipe entries. Consider optimizing the project configuration to reduce memory usage. - Event ID: 50000
- Firmware update error. The firmware transfer to the panel was interrupted or failed.
Repeat the firmware update procedure using ProSave or WinCC flexible. Ensure stable power supply during the update process. - Event ID: 70000
- Recipe data error. A recipe record could not be read or written correctly.
Check the recipe configuration in WinCC flexible. Verify that the recipe data areas in the PLC data blocks are correctly mapped and accessible. - Event ID: 80000
- Alarm buffer overflow. The number of pending alarms exceeds the buffer capacity.
Acknowledge and clear existing alarms. Review the alarm configuration to reduce the frequency of alarm events or increase the buffer size in the project settings.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-1200 in some configurations using appropriate protocol settings.
What software is used to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible software. The project is then transferred to the panel via MPI, PROFIBUS DP, or a USB/serial connection using ProSave.
What is the supply voltage for the 6AV6355-1CA47-7ES1?
The panel operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational issues.
Is the OP 77B front panel rated for washdown or dusty environments?
Yes, the front face of the OP 77B carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the unit is rated IP20.
Can the OP 77B display graphical content?
The OP 77B is primarily a text-based operator panel with a 160 x 64 pixel STN LCD display. It can display simple graphics and bar graphs but is not designed for complex graphical HMI applications.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the power supply wiring for loose connections.
Ensure the supply voltage is within the 24 V DC specification. Replace any blown fuse and secure all wiring connections. If the display remains blank, the internal power supply or display unit may require replacement.
Panel shows communication error and cannot connect to PLC
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address and baud rate configured in WinCC flexible match the actual PLC settings.
Correct any address or baud rate mismatches in the WinCC flexible project and reload it to the panel. Replace the communication cable if damaged. Ensure termination resistors are installed at both ends of the PROFIBUS segment.
Project cannot be transferred to the panel
Confirm the transfer cable is correctly connected and the panel is in transfer mode. Check that the WinCC flexible version is compatible with the panel firmware version.
Set the panel to transfer mode via the Start Center menu. Use ProSave to update the firmware if there is a version mismatch. Try an alternative transfer cable or connection method if the issue persists.
Operator keys are unresponsive or behave incorrectly
Inspect the keypad for physical damage or contamination. Check the project configuration to confirm the function key assignments are correctly defined in WinCC flexible.
Clean the keypad surface and check for any mechanical obstruction. If keys are physically damaged, the keypad membrane may need replacement. Reload the project to rule out a configuration issue.
Alarm messages are not displayed or acknowledged correctly
Review the alarm configuration in WinCC flexible to ensure alarm events are correctly linked to PLC data bits. Check that the alarm buffer has not overflowed.
Acknowledge and clear all pending alarms. Verify the PLC data bit addresses assigned to alarm triggers are correct and active. Reload the project if the alarm configuration was recently modified.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page