• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ES1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ES1 OP 77B

    € 939,56

    Reset
    Clear
    SKU: 6AV6355-1CA47-7ES1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ES1 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels series. It is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface tasks. This unit provides a text-based display with function keys for direct process control and monitoring without the need for a touchscreen interface.

    The OP 77B features a 4-line STN LCD display capable of showing alphanumeric text and basic graphics, with a resolution of 160 x 64 pixels. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports recipe management, alarm logging, and trend display functions. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77B is widely used in manufacturing, packaging, and process automation applications where a cost-effective, robust operator interface is required at the machine level. Its compatibility with the SIMATIC S7 PLC family makes it a practical choice for retrofitting or extending existing Siemens automation systems. The panel is suited for environments where a simple, reliable text-based interface is preferred over more complex graphical touchscreen solutions.

    Technical Specifications

    Display Type STN LCD
    Display Resolution 160 x 64 pixels
    Display Lines 4 lines of text
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 5 W
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 77B

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the configured controller cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI configuration in WinCC flexible.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect communication cables for damage or loose connectors. Confirm the PLC is powered and running. Re-establish the connection and check for network address conflicts.
    Event ID: 20000
    Configuration error detected. The project loaded on the panel is incompatible or corrupt.
    Reload the project from WinCC flexible to the panel. Ensure the WinCC flexible version used is compatible with the OP 77B firmware version.
    Event ID: 40000
    System memory low. Insufficient memory available for the current operation.
    Reduce the number of active alarms or recipe entries. Consider optimizing the project configuration to reduce memory usage.
    Event ID: 50000
    Firmware update error. The firmware transfer to the panel was interrupted or failed.
    Repeat the firmware update procedure using ProSave or WinCC flexible. Ensure stable power supply during the update process.
    Event ID: 70000
    Recipe data error. A recipe record could not be read or written correctly.
    Check the recipe configuration in WinCC flexible. Verify that the recipe data areas in the PLC data blocks are correctly mapped and accessible.
    Event ID: 80000
    Alarm buffer overflow. The number of pending alarms exceeds the buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration to reduce the frequency of alarm events or increase the buffer size in the project settings.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B panel?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports communication with S7-1200 in some configurations using appropriate protocol settings.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible software. The project is then transferred to the panel via MPI, PROFIBUS DP, or a USB/serial connection using ProSave.

    What is the supply voltage for the 6AV6355-1CA47-7ES1?

    The panel operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational issues.

    Is the OP 77B front panel rated for washdown or dusty environments?

    Yes, the front face of the OP 77B carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the unit is rated IP20.

    Can the OP 77B display graphical content?

    The OP 77B is primarily a text-based operator panel with a 160 x 64 pixel STN LCD display. It can display simple graphics and bar graphs but is not designed for complex graphical HMI applications.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the power supply wiring for loose connections.

    Ensure the supply voltage is within the 24 V DC specification. Replace any blown fuse and secure all wiring connections. If the display remains blank, the internal power supply or display unit may require replacement.

    Panel shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address and baud rate configured in WinCC flexible match the actual PLC settings.

    Correct any address or baud rate mismatches in the WinCC flexible project and reload it to the panel. Replace the communication cable if damaged. Ensure termination resistors are installed at both ends of the PROFIBUS segment.

    Project cannot be transferred to the panel

    Confirm the transfer cable is correctly connected and the panel is in transfer mode. Check that the WinCC flexible version is compatible with the panel firmware version.

    Set the panel to transfer mode via the Start Center menu. Use ProSave to update the firmware if there is a version mismatch. Try an alternative transfer cable or connection method if the issue persists.

    Operator keys are unresponsive or behave incorrectly

    Inspect the keypad for physical damage or contamination. Check the project configuration to confirm the function key assignments are correctly defined in WinCC flexible.

    Clean the keypad surface and check for any mechanical obstruction. If keys are physically damaged, the keypad membrane may need replacement. Reload the project to rule out a configuration issue.

    Alarm messages are not displayed or acknowledged correctly

    Review the alarm configuration in WinCC flexible to ensure alarm events are correctly linked to PLC data bits. Check that the alarm buffer has not overflowed.

    Acknowledge and clear all pending alarms. Verify the PLC data bit addresses assigned to alarm triggers are correct and active. Reload the project if the alarm configuration was recently modified.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart