Siemens 6AV6355-1CA47-7ES3 OP 77B
€ 1.995,00
The Siemens 6AV6355-1CA47-7ES3 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator device is designed for human-machine interface applications, providing a text-based display and keypad input for machine monitoring and control tasks. It is part of the SIMATIC HMI Basic Panels generation and is intended for use with Siemens SIMATIC S7 and other compatible controllers.
The OP 77B features a monochrome STN LCD display capable of showing text and simple graphics, supported by a membrane keypad for operator input. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel supports configuration through Siemens WinCC flexible software and offers a compact, panel-mount form factor with an IP65 protection rating on the front face, making it suitable for installation in control cabinet doors.
This operator panel is widely used in manufacturing, machine building, and process automation environments where a cost-effective, reliable HMI solution is required. Typical applications include conveyor systems, packaging machinery, and general-purpose machine control where text-based status display and parameter entry are sufficient. Its compatibility with the established SIMATIC S7 controller range makes it a practical choice for retrofitting or extending existing automation installations.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Size | 4 lines x 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 3.5 W (typical) |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Configuration Software | WinCC flexible 2008 or higher |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC controller
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. - Event ID: 10001
- Connection to PLC interrupted or PLC not responding
Verify the PLC is powered and in RUN mode. Check the communication cable and bus address configuration in WinCC flexible. - Event ID: 20000
- Project download error or project data corrupted on the panel
Re-download the project from WinCC flexible to the panel. Ensure the WinCC flexible version is compatible with the panel firmware version. - Event ID: 40000
- System memory low or insufficient memory for project execution
Reduce the project size by removing unused screens or tags. Check that the project does not exceed the panel memory limits. - Event ID: 70010
- Firmware version mismatch between the panel and the loaded project
Update the panel firmware using the ProSave tool or re-download the project using a compatible version of WinCC flexible. - Event ID: 50000
- Tag or variable address not accessible in the connected PLC
Verify that the PLC data block or memory address referenced in the HMI project exists and is correctly configured in the PLC program.
Frequently Asked Questions
Which communication interfaces does the OP 77B support?
The OP 77B supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs.
What software is required to configure the 6AV6355-1CA47-7ES3?
The panel is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via the MPI interface or a PC adapter cable.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B carries an IP65 protection rating, making it suitable for installation in control cabinet doors where dust and water spray may be present.
What is the supply voltage for the 6AV6355-1CA47-7ES3?
The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI devices and compatible with typical control cabinet power supplies.
Can the OP 77B be used with third-party PLCs?
The OP 77B is primarily designed for use with Siemens SIMATIC S7 controllers. Limited support for third-party controllers may be available through WinCC flexible drivers, but compatibility should be verified before use.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check the supply polarity and verify the cable is correctly seated.
Correct any wiring errors and ensure the 24 V DC supply is within the specified tolerance. If the supply is correct and the display remains blank, the internal power supply or display unit may require replacement.
Panel displays communication error and cannot connect to PLC
Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends of the bus. Verify the bus address configured in the HMI project matches the physical address set on the PLC.
Replace or re-terminate the communication cable as needed. Correct the bus address settings in WinCC flexible and re-download the project to the panel.
Project download from WinCC flexible fails or times out
Verify the PC adapter or MPI cable is correctly connected and the correct COM port and transfer speed are selected in WinCC flexible. Check that the panel is in transfer mode.
Set the panel to transfer mode via the panel start screen, select the correct interface settings in WinCC flexible, and retry the download. Update PC adapter drivers if necessary.
Operator keys are unresponsive or register incorrect inputs
Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically using the panel's built-in key test function if available.
Clean the keypad surface with a dry cloth. If keys remain unresponsive, the membrane keypad assembly may need to be replaced as a spare part.
Panel repeatedly restarts or enters a boot loop
Check the 24 V DC supply for voltage drops or ripple that may cause under-voltage resets. Verify the project file is not corrupted by attempting to re-download from WinCC flexible.
Stabilize the power supply and ensure it can deliver sufficient current. Re-download the project to the panel. If the issue persists, perform a factory reset using the ProSave tool and reload the firmware and project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page