• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7ER6 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7ER6 OP 177B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7ER6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7ER6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome or color graphical display with touch and key-based operation, serving as a compact yet capable panel for process visualization and control. As part of the SIMATIC HMI comfort and mobile panel lineage, it integrates seamlessly into Siemens automation environments.

    The OP 177B features a 5.7-inch STN display with a resolution of 320 x 240 pixels and supports both MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7 PLCs. It includes Ethernet connectivity for network integration and supports configuration via WinCC flexible engineering software. The panel offers a robust membrane keypad with function keys, providing reliable tactile input in industrial environments, and is rated for operation across a wide temperature range.

    The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries where compact operator panels are required at the machine level. Its compatibility with SIMATIC S7-300 and S7-400 controllers makes it suitable for a broad range of machine control and monitoring applications. The panel's compact form factor and versatile communication options make it a practical choice for retrofit and new installation projects alike.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels
    Display Type STN color LCD
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (RJ45)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP 177B
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2008

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP or Ethernet cable connections and termination resistors. Verify PLC address settings and communication parameters in WinCC flexible project match the hardware configuration.
    Event ID: 10001
    Connection to PLC timeout. The HMI panel did not receive a response from the controller within the configured timeout period.
    Check network cabling and connector integrity. Verify PLC is in RUN mode and the configured station address is correct. Increase timeout value in the HMI project if necessary.
    Event ID: 20000
    Project download error. The transfer of the HMI project from the engineering PC to the panel failed.
    Ensure the panel is in Transfer mode. Verify the communication interface settings on both the PC and panel match. Check that WinCC flexible version is compatible with the panel firmware version.
    Event ID: 40000
    Tag read/write error. The HMI panel is unable to read from or write to a configured PLC tag or data block.
    Verify the tag address and data type in the WinCC flexible project match the actual PLC data structure. Check PLC program for correct DB or memory area definitions.
    Event ID: 110000
    System memory low. The panel's available runtime memory is insufficient to execute the current project.
    Reduce the number of active screens, images, or scripts in the project. Optimize the project in WinCC flexible to reduce memory usage and re-download to the panel.
    Event ID: 130000
    Firmware update error. An error occurred during the firmware update process on the panel.
    Restart the firmware update procedure using ProSave or WinCC flexible. Ensure the power supply is stable during the update and the correct firmware version for the OP 177B is used.
    Event ID: 50000
    Illegal system state detected. The panel has encountered an internal error and may restart automatically.
    Perform a controlled restart of the panel. If the error persists, back up the project, perform a factory reset using the panel's Start Center, and re-download the project.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1CA47-7ER6) support?

    The OP 177B supports MPI, PROFIBUS DP, and Ethernet (RJ45) interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs as well as network-based communication.

    Which engineering software is used to configure the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2008 or later compatible versions. Projects are downloaded to the panel via MPI, PROFIBUS, Ethernet, or USB connection.

    What is the supply voltage for the 6AV6355-1CA47-7ER6?

    The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to prevent operational issues.

    Is the OP 177B compatible with SIMATIC S7-1200 or S7-1500 PLCs?

    The OP 177B is primarily designed for use with S7-200, S7-300, and S7-400 PLCs via WinCC flexible. Compatibility with S7-1200 and S7-1500 is limited and these newer controllers are better supported by TIA Portal-based HMI panels such as the KTP or Comfort series.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for typical industrial machine environments.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown internal fuse or incorrect polarity on the supply connection.

    Correct the supply voltage or polarity. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight inverter may require replacement or the unit may need to be sent for repair.

    Panel shows 'No connection to PLC' or communication errors on screen

    Check the MPI, PROFIBUS DP, or Ethernet cable between the panel and the PLC. Verify bus termination resistors are correctly placed at both ends of the PROFIBUS segment. Confirm the station address configured in the HMI project matches the physical PLC address.

    Replace or reseat communication cables. Correct bus termination. Update the HMI project communication settings in WinCC flexible to match the PLC configuration and re-download the project.

    Touchscreen or function keys are unresponsive

    Attempt to operate the panel using both the touchscreen and the physical function keys to isolate the fault. Check for physical damage to the membrane keypad or display surface. Perform a touchscreen calibration from the panel's Start Center.

    Recalibrate the touchscreen via the Start Center menu. If the membrane keypad is damaged, replace the front panel assembly. If the touchscreen remains unresponsive after calibration, the touch controller hardware may require repair or replacement.

    Project transfer from PC to panel fails repeatedly

    Verify the panel is set to Transfer mode via the Start Center. Check that the communication interface selected in WinCC flexible matches the physical connection being used. Confirm the PC firewall or antivirus software is not blocking the transfer.

    Set the correct transfer interface on both the panel and in WinCC flexible. Disable firewall or antivirus temporarily during transfer. Ensure the WinCC flexible version is compatible with the panel firmware version; update firmware via ProSave if necessary.

    Panel restarts unexpectedly or displays a system error message

    Check the 24 V DC supply for voltage dips or instability using a multimeter or oscilloscope. Review the system event log accessible from the panel's Start Center for specific event IDs. Inspect the installation environment for excessive temperature or vibration.

    Stabilize the power supply and ensure it meets the panel's current requirements. Address any environmental issues such as excessive heat or vibration. If the problem persists, perform a factory reset from the Start Center and re-download the project from WinCC flexible.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart