• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CL4 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CL4 OP 77B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CL4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CL4 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. This compact panel operator unit is designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. The OP 77B series is part of the broader SIMATIC HMI Micro/Basic panel lineup, intended for cost-effective yet reliable HMI solutions.

    The OP 77B features a monochrome LCD display with a resolution of 160 x 80 pixels and a membrane keypad for operator input, eliminating the need for a touchscreen while maintaining robust usability in industrial environments. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel is configured using Siemens WinCC flexible software and supports basic HMI functions including alarm management, recipe handling, and process value display. The unit operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77B is widely deployed in machine building, packaging machinery, conveyor systems, and general factory automation where a compact, keypad-operated interface is preferred over a full touchscreen panel. Its small footprint and panel-mount design make it suitable for integration into control cabinet doors and machine enclosures with limited space. The direct PROFIBUS DP connectivity makes it particularly well-suited for distributed automation architectures common in manufacturing and process industries.

    Technical Specifications

    Display Type Monochrome LCD
    Display Resolution 160 x 80 pixels
    Input Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Configuration Software WinCC flexible 2005 or higher
    Series/Product Family SIMATIC HMI OP 77B
    Certifications CE, UL
    Input Method Membrane keypad

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI project configuration. Confirm the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation. The panel lost communication with the controller.
    Inspect the communication cable for damage or loose connectors. Check network topology and ensure proper bus termination. Restart both the HMI panel and the PLC if the connection does not recover automatically.
    Event ID: 20000
    Configuration error detected. The project loaded on the panel is incompatible or corrupt.
    Re-transfer the HMI project from the engineering PC using WinCC flexible. Verify the project was compiled without errors before transfer.
    Event ID: 40000
    System memory low. The panel is running low on available runtime memory.
    Reduce the number of active alarms or data logs. Simplify the project if possible and re-transfer. Consider archiving or clearing alarm logs stored on the device.
    Event ID: 50000
    Tag read/write error. A configured process tag could not be read from or written to the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program to ensure the address is accessible and not write-protected.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the PLC program and process conditions to resolve the root causes of the alarms. Increase alarm buffer size in the WinCC flexible project if supported.
    Event ID: 70000
    Operating system or firmware error detected on the HMI panel.
    Perform a panel reset by cycling power. If the error persists, update the panel firmware using the Siemens ProSave tool or re-transfer the project. Contact Siemens technical support if the fault cannot be cleared.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B panel?

    The OP 77B supports direct communication with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via PPI protocol depending on configuration.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are transferred to the panel via an MPI or PROFIBUS DP connection from the engineering PC.

    What is the supply voltage for the 6AV6355-1CA47-7CL4?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational issues.

    Is the OP 77B panel rated for outdoor use?

    The front face of the OP 77B carries an IP65 rating, making it suitable for panel-mount installations where the front is exposed to dust and water splashing. The rear of the unit is rated IP20 and must be protected within an enclosure.

    Can the OP 77B display graphics or images?

    The OP 77B uses a monochrome LCD display with a resolution of 160 x 80 pixels and is primarily intended for text-based process value display, alarm messages, and simple bar graphs. It does not support full graphical or bitmap image display.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the acceptable voltage range and that the connector is fully seated.

    Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, inspect the internal fuse if accessible, or replace the panel unit as the internal power circuitry may have failed.

    Panel shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and that bus termination resistors are properly placed at both ends of the network. Check that the PLC station address and baud rate configured in the HMI project match the actual PLC settings.

    Correct any address or baud rate mismatches in the WinCC flexible project and re-transfer. Replace the communication cable if damaged. Ensure only one active bus termination exists at each end of the PROFIBUS or MPI segment.

    HMI project transfer fails from engineering PC

    Confirm the PC-to-panel connection cable is functional and the correct COM port or USB-to-MPI adapter is selected in WinCC flexible. Check that the panel is in transfer mode before initiating the download.

    Place the panel in transfer mode via the Start Center menu. Use a known-good Siemens PC/MPI adapter or PROFIBUS cable. Reinstall the WinCC flexible runtime or update the panel firmware using ProSave if transfer errors persist.

    Alarm messages are not displaying on the panel

    Check the alarm configuration in the WinCC flexible project to ensure alarm tags are correctly mapped to PLC addresses. Verify the PLC program is setting the alarm bits as expected by monitoring the PLC online.

    Correct any tag address mismatches in the HMI project and re-transfer. Confirm the PLC logic is functioning correctly and that alarm trigger conditions are being met. Clear any alarm buffer overflow conditions on the panel.

    Panel keypad buttons are unresponsive

    Inspect the membrane keypad for physical damage, contamination, or wear. Attempt a panel restart by cycling the 24 V DC power supply to rule out a software lockup.

    Clean the keypad surface if contamination is present. If individual keys remain unresponsive after restart, the membrane keypad assembly may require replacement. Contact a qualified repair technician or return the unit for refurbishment.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart