• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CM1 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CM1 OP 77B

    € 1.908,70

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CM1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CM1 is an operator panel belonging to the OP 77B series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This unit is a compact, key-operated operator panel designed for straightforward machine-level human-machine interface tasks. It provides a monochrome display with a numeric and function key layout suited for parameter entry and status monitoring in industrial environments.

    The OP 77B features a built-in MPI/PROFIBUS DP interface for direct communication with SIMATIC S7 PLCs, enabling seamless integration into existing Siemens automation architectures. The panel supports configuration via SIMATIC WinCC flexible software and offers onboard flash memory for storing project data and recipes. It is designed to operate within a wide industrial temperature range and carries the necessary certifications for use in demanding environments, with a front panel protection rating of IP65.

    The OP 77B is widely deployed in machine building, manufacturing automation, and process control applications where a cost-effective, reliable operator interface is required. Its compact form factor and robust keypad design make it suitable for installation in control cabinet doors and machine panels where touchscreen operation is not required. Industries such as automotive manufacturing, food and beverage processing, and general factory automation commonly use this panel for local operator control and diagnostics.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI / PROFIBUS DP
    Configuration Software SIMATIC WinCC flexible 2005 or higher
    Memory 512 KB flash (user memory)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 77B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The MPI/PROFIBUS DP connection has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Connection to the configured PLC address has timed out. The panel cannot reach the controller within the expected time window.
    Verify bus address settings on both the HMI and PLC. Check cable integrity and bus termination. Reduce bus length or check for electrical interference on the cable.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of the configuration project from the engineering PC to the panel.
    Check the transfer cable connection. Ensure WinCC flexible project is compiled without errors. Set the panel to transfer mode and retry the download.
    Event ID: 40000
    System memory overflow. The available user memory on the panel is insufficient for the loaded project.
    Reduce the project size by removing unused screens, tags, or recipe data. Recompile and re-download the project using WinCC flexible.
    Event ID: 50000
    Tag update error. One or more configured tags cannot be read from the PLC within the configured polling cycle.
    Check PLC program to ensure the configured data blocks and addresses exist. Verify tag addresses in the WinCC flexible project match the PLC data structure.
    Event ID: 60000
    Operating system error or internal panel fault detected. The panel firmware has encountered an unexpected system state.
    Perform a panel restart by cycling the 24 V DC power supply. If the fault persists, perform a factory reset and re-download the project. Contact Siemens technical support if the issue recurs.
    Event ID: 70000
    Recipe data error. A fault occurred during reading or writing of recipe records, possibly due to data inconsistency.
    Check recipe configuration in WinCC flexible for correct data types and address assignments. Clear recipe data on the panel and re-download the project.

    Frequently Asked Questions

    Which communication interfaces does the OP 77B (6AV6355-1CA47-7CM1) support?

    The OP 77B supports MPI and PROFIBUS DP interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without additional communication modules.

    Which software is used to configure the OP 77B?

    The OP 77B is configured using Siemens SIMATIC WinCC flexible 2005 or later versions. Projects are downloaded to the panel via the MPI interface or a dedicated PC/PPI cable.

    What is the supply voltage for the 6AV6355-1CA47-7CM1?

    The panel requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid operational faults.

    What is the front panel protection rating of the OP 77B?

    The front panel of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial cabinet door mounting.

    Can the OP 77B display graphical content or images?

    No, the OP 77B uses a character-based monochrome LCD display and does not support graphical images or bitmap graphics. It is limited to text-based screens with numeric and alphanumeric content.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within the specified tolerance. Inspect the internal fuse if accessible.

    Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good but the display remains blank, the panel's internal power supply or display unit may be faulty and the unit should be sent for repair or replacement.

    HMI panel shows persistent communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP address configured in the WinCC flexible project matches the address set on the panel and the PLC. Check the bus cable for continuity and correct termination at both ends of the bus.

    Correct any address mismatches in the project or on the panel. Replace damaged cables and ensure bus termination resistors are active only at the two physical ends of the bus segment. Restart both the panel and the PLC.

    Project download fails or transfer does not start

    Confirm the panel is set to transfer mode. Check the MPI cable connection between the engineering PC and the panel. Verify that the correct communication port and transfer settings are selected in WinCC flexible.

    Switch the panel to transfer mode via the Start Center menu. Use a known-good MPI transfer cable. Recompile the WinCC flexible project and retry the download. Temporarily disable PC firewall or antivirus software that may block the transfer.

    Panel repeatedly restarts or enters a boot loop

    Check the 24 V DC supply for voltage dips or instability under load. Inspect the project for configuration errors that may cause a runtime crash on startup.

    Stabilize the power supply and ensure adequate current capacity. Perform a factory reset on the panel to clear the existing project, then re-download a freshly compiled project from WinCC flexible.

    Keypad buttons do not respond or register incorrect inputs

    Inspect the keypad membrane for physical damage, contamination, or deformation. Test each key systematically using a diagnostic screen if available in the project.

    Clean the keypad area with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly should be replaced. This typically requires disassembly of the panel front housing.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart