• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CL2 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CL2 OP 77B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CL2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CL2 is an operator panel belonging to the OP 77B series, part of the SIMATIC HMI Basic Panels product family manufactured by Siemens. This compact operator panel is designed for machine-level human-machine interface applications, providing a straightforward interface for process monitoring and control. It is a key component in Siemens' portfolio of entry-level HMI devices, intended for use with SIMATIC S7 PLCs and compatible controllers.

    The OP 77B features a monochrome STN LCD display and supports key-based operation, providing a reliable and durable input method suited to industrial environments. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. The panel supports configuration through WinCC flexible software and offers a range of display and control functions including alarm management, recipe handling, and trend displays. Its robust housing is rated to IP65 on the front face, protecting against dust and water ingress in demanding production environments.

    The OP 77B is widely deployed in manufacturing, automotive, food and beverage, and packaging industries where a cost-effective, reliable operator interface is required at the machine level. It is particularly suited for applications where alphanumeric display of process values, alarm messages, and operator prompts is sufficient without the need for graphical visualization. The panel's compatibility with the broad SIMATIC S7 controller family makes it a flexible choice for both new installations and retrofit projects.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4 lines x 20 characters
    Communication Interface MPI, PROFIBUS DP
    Input/Operating Voltage 24 V DC
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Mounting Panel mounting
    Configuration Software WinCC flexible 2008 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 77B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The connection to the controller has been interrupted or cannot be established.
    Check MPI or PROFIBUS DP cable connections and terminating resistors. Verify the PLC address settings match the HMI configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was established but subsequently lost during operation.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify PLC program is running and not in STOP state.
    Event ID: 20000
    Configuration or project download error. The project loaded on the panel is incompatible or corrupt.
    Re-download the project from WinCC flexible to the panel. Ensure the WinCC flexible version matches the firmware version of the panel. Perform a panel reset if the issue persists.
    Event ID: 40000
    Tag read/write error. The HMI is unable to read from or write to a configured PLC tag.
    Verify the PLC tag addresses in the WinCC flexible project are correct and match the PLC program. Check that the PLC data blocks or memory areas referenced are present and accessible.
    Event ID: 50000
    System memory low. The panel's internal memory is approaching capacity.
    Review and reduce the number of alarms, recipes, or data logs stored on the device. Archive or delete historical data to free up internal memory.
    Event ID: 60000
    Firmware update error. A firmware update process was interrupted or failed to complete successfully.
    Restart the firmware update procedure using the correct firmware version for the OP 77B. Ensure stable power supply during the update process and use the correct ProSave or WinCC flexible tool.
    Event ID: 70000
    Operating system or internal hardware fault detected on the panel.
    Perform a factory reset of the panel. If the fault persists after reset, the unit likely requires repair or replacement of internal components.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7CL2)?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.

    What software is used to configure the OP 77B?

    The OP 77B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via the MPI interface or a USB-to-MPI adapter.

    What is the supply voltage for the 6AV6355-1CA47-7CL2?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to prevent operational faults.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B is rated to IP65, providing protection against dust and low-pressure water jets, making it suitable for installation in industrial control panels.

    Can the OP 77B display graphical content?

    No, the OP 77B uses a character-based monochrome LCD display and does not support graphical visualization. It is designed for alphanumeric display of process values, alarms, and operator messages.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector. Verify the supply is within the specified voltage range and that the connector is firmly seated.

    Restore correct 24 V DC supply. If the supply is confirmed correct and the display remains blank, inspect the internal fuse and power supply circuitry. The panel may require internal repair or replacement.

    Panel shows 'No connection to PLC' or communication error message

    Verify the MPI or PROFIBUS DP cable is connected to the correct port on both the panel and the PLC. Check the bus address settings in the WinCC flexible project match the PLC configuration. Inspect cable termination resistors at both ends of the bus.

    Correct any address mismatches in the project configuration and re-download. Replace damaged cables or connectors. Ensure bus termination is correctly applied at both physical ends of the MPI or PROFIBUS network.

    Keys on the panel are unresponsive or intermittently responsive

    Inspect the keypad membrane for physical damage, contamination, or wear. Check if the issue is consistent across all keys or isolated to specific ones.

    Clean the keypad surface with a dry cloth. If keys remain unresponsive, the keypad membrane assembly likely requires replacement. Contact a qualified repair technician to replace the membrane.

    Project download from WinCC flexible fails or times out

    Verify the MPI communication cable and adapter are functioning correctly. Confirm the correct COM port and transfer settings are selected in WinCC flexible. Check that the panel is in transfer mode.

    Place the panel in transfer mode via the panel's start center menu. Use a known-good MPI cable and adapter. Ensure the WinCC flexible project is compiled without errors before attempting the download.

    Panel repeatedly restarts or enters a boot loop

    This may indicate a corrupt project file on the panel or a firmware issue. Attempt to access the panel's start center during boot by pressing the appropriate key combination.

    Use ProSave or WinCC flexible to perform a firmware restore or factory reset. Re-download a freshly compiled project after the reset. If the boot loop continues, the panel's internal flash memory or hardware may be faulty and require professional repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart