• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CF2 OP 77B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CF2 OP 77B

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6AV6355-1CA47-7CF2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CF2 is an operator panel belonging to the OP 77B series within the Siemens SIMATIC HMI product family. It is a compact, key-operated operator panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automated processes. This unit is part of the SIMATIC HMI Basic Panels generation and is manufactured by Siemens AG.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 160 pixels and a backlit screen for clear readability in various lighting conditions. It supports communication via PROFIBUS DP and MPI interfaces, enabling direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keypad with function keys, system keys, and numeric entry keys, and is configured using Siemens WinCC flexible software. It operates on a 24 V DC supply and carries an IP65 protection rating on the front face.

    The OP 77B is widely used in manufacturing, packaging, and process automation environments where a cost-effective, robust operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine enclosures. Industries such as automotive, food and beverage, and general factory automation commonly deploy this panel for local operator interaction with Siemens PLC-controlled machinery.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 160 pixels
    Display Size 4 inch
    Input Voltage 24 V DC
    Communication Interface PROFIBUS DP, MPI
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Configuration Software WinCC flexible 2005 or higher
    Mounting Panel mount
    Certifications CE, UL, cULus
    Series SIMATIC HMI OP 77B

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
    Check PROFIBUS DP or MPI cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The panel lost communication with the controller after an initial successful connection.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify bus termination at both ends of the PROFIBUS segment.
    Event ID: 20000
    Project download error. The configuration project could not be successfully transferred to the panel.
    Verify the USB or serial connection between the engineering PC and the panel. Ensure WinCC flexible version is compatible with the panel firmware. Retry the download after restarting both the panel and the engineering software.
    Event ID: 40000
    Tag read error. The panel is unable to read the value of a configured process tag from the PLC.
    Check that the PLC data block or memory address referenced by the tag exists and is accessible. Verify the tag address configuration in WinCC flexible matches the PLC program.
    Event ID: 40001
    Tag write error. The panel failed to write a value to a configured process tag in the PLC.
    Confirm the PLC is in RUN mode and the target memory area is not write-protected. Check the tag address and data type configuration in the HMI project.
    System Event: Firmware Update Failed
    A firmware update procedure was interrupted or failed to complete, leaving the panel in an inconsistent state.
    Restart the panel and attempt the firmware update again using the correct firmware version for the OP 77B. Ensure stable power supply during the update process.
    System Event: Backlight Failure
    The LCD backlight has failed or reached end of life, resulting in a dark or very dim display.
    The backlight is not field-replaceable on this panel. The unit should be returned for repair or replacement of the display assembly.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP 77B (6AV6355-1CA47-7CF2)?

    The OP 77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.

    What software is used to configure the OP 77B panel?

    The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are downloaded to the panel via a USB or serial connection from the engineering PC.

    What is the supply voltage for the 6AV6355-1CA47-7CF2?

    The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to guarantee reliable operation.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel-mount installations.

    Can the OP 77B display process values in real time?

    Yes, the OP 77B can display real-time process values, alarms, and status information by reading tags directly from the connected Siemens PLC via MPI or PROFIBUS DP communication.

    Troubleshooting

    Display is blank or very dim after power on

    Check the 24 V DC supply voltage at the panel power connector. Verify the supply is within tolerance. If voltage is correct, the backlight may have failed.

    Ensure the 24 V DC supply is stable and correctly connected. If the supply is confirmed good and the display remains dark, the backlight or display assembly requires replacement by a qualified repair technician.

    Panel shows communication error and cannot connect to PLC

    Verify the PROFIBUS DP or MPI cable is correctly connected and terminated. Check that the PLC address configured in the HMI project matches the actual PLC station address. Confirm the PLC is powered and in RUN mode.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables or connectors. Ensure bus termination resistors are correctly placed at both ends of the PROFIBUS segment.

    Project download from WinCC flexible fails

    Check the physical connection between the engineering PC and the panel (USB or serial cable). Verify that the WinCC flexible software version supports the OP 77B and that the correct panel type is selected in the project.

    Use a known-good transfer cable and retry the download. Ensure the panel is in transfer mode before initiating the download. Update WinCC flexible to a compatible version if necessary.

    Function keys do not respond when pressed

    Inspect the membrane keypad for physical damage or contamination beneath the keys. Check the HMI project to confirm function key assignments are correctly configured and downloaded.

    Clean the keypad surface if contamination is present. If keys are physically damaged, the keypad membrane requires replacement. Re-download the project if key assignments appear to be missing.

    Panel repeatedly restarts or enters a boot loop

    This may indicate a corrupted project file on the panel, a firmware issue, or an unstable power supply. Measure the 24 V DC supply for voltage drops or ripple.

    Stabilize the power supply if voltage irregularities are found. Perform a factory reset on the panel and re-download the project. If the issue persists, update the panel firmware to the latest compatible version.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart