Siemens 6AV6355-1CA47-7CF4 OP 77B
€ 2.995,00
The Siemens 6AV6355-1CA47-7CF4 is an OP 77B operator panel belonging to the SIMATIC HMI family of human-machine interface devices. This compact panel is designed for machine-level operator control and monitoring tasks, providing a straightforward interface for process visualization and parameter input. It is part of Siemens' established line of text-based operator panels intended for integration into industrial control systems.
The OP 77B features a monochrome LCD display capable of showing text and simple graphics, with a membrane keypad for operator input including function keys and numeric entry. It supports MPI and PROFIBUS DP communication interfaces for direct connection to SIMATIC S7 PLCs, as well as point-to-point serial communication. The panel operates on 24 V DC supply voltage and is built to withstand industrial environments, carrying a front-panel IP65 protection rating. Configuration is performed using Siemens WinCC flexible engineering software.
The OP 77B is commonly deployed in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. It is well suited for controlling conveyor systems, packaging machinery, and general-purpose industrial equipment where text-based status display and parameter entry are sufficient. Its compact form factor and robust construction make it appropriate for panel mounting in space-constrained control cabinets.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Lines | 4 lines of text |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP, RS-422/RS-485 (PtP) |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC flexible 2005 or higher |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
Common Error Codes & System Events
- Event ID: 1003
- Connection to the PLC could not be established or has been lost during operation.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the panel configuration. Confirm the PLC is powered and in RUN mode. - Event ID: 10000
- Tag read error — the panel cannot read a configured tag from the PLC.
Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check communication link integrity. - Event ID: 10001
- Tag write error — the panel cannot write a value to the configured PLC tag.
Check that the target PLC memory area is not write-protected. Verify the tag address and data type configuration in the WinCC flexible project. - Event ID: 20000
- System memory low — available panel memory is insufficient for the current project or runtime operation.
Reduce the number of active screens or objects in the project. Transfer an optimized project to the panel using WinCC flexible. - Event ID: 40000
- Operating system error — an internal system fault has been detected.
Perform a panel reset by cycling power. If the fault persists, reload the operating system and project via WinCC flexible ProSave tool. - Event ID: 70010
- Configuration transfer error — project download to the panel was interrupted or failed.
Check the PC-to-panel transfer cable and connection settings. Ensure the panel is in transfer mode and retry the download from WinCC flexible.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. Point-to-point serial communication with other controllers is also supported via the RS-422/RS-485 port.
What software is required to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via a PC adapter cable connected to the MPI interface or serial port.
What is the supply voltage for the 6AV6355-1CA47-7CF4?
The panel requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to guarantee reliable operation.
What is the front panel protection rating of the OP 77B?
The OP 77B has an IP65 protection rating on the front face, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Can the OP 77B display graphics or only text?
The OP 77B is primarily a text-based operator panel with a monochrome LCD. It can display simple bar graphs and symbols in addition to text, but it is not designed for full graphical visualization.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check for blown fuses in the supply circuit and inspect the power cable for continuity.
Restore correct 24 V DC supply voltage within the specified tolerance. Replace any blown fuses and ensure secure connector seating. If the display remains blank with correct supply voltage, the internal power supply or display unit may require replacement.
Panel shows 'No connection to PLC' or communication error on screen
Verify MPI or PROFIBUS DP bus cable connections at both the panel and PLC ends. Check bus termination resistors are correctly placed at both ends of the network segment. Confirm the PLC station address matches the address configured in the WinCC flexible project.
Reseat all bus connectors and replace any damaged cables. Set correct termination on the bus. Correct the PLC address in the WinCC flexible project and retransfer the project to the panel.
Project transfer from PC to panel fails or times out
Check that the panel is set to transfer mode before initiating the download. Verify the PC adapter cable type and COM port settings in WinCC flexible match the physical connection.
Place the panel in transfer mode via the panel's start menu. Select the correct interface and baud rate in WinCC flexible. Replace the PC adapter cable if communication cannot be established after confirming settings.
Function keys do not respond when pressed
Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key in a diagnostic screen if accessible. Check whether the issue is limited to specific keys or affects the entire keypad.
Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad assembly will need to be replaced. Contact a qualified repair technician for membrane keypad replacement.
Panel restarts repeatedly or enters a boot loop
Check the 24 V DC supply for voltage dips or instability under load. Inspect the loaded project for configuration errors that may cause a runtime crash on startup.
Stabilize the power supply and ensure adequate current capacity. Use WinCC flexible ProSave to reload the panel operating system and transfer a verified project. If the issue persists, the panel hardware may require service or replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page