• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1CA47-7CA3 OP 177B
    Awaiting product image

    Siemens 6AV6355-1CA47-7CA3 OP 177B

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6355-1CA47-7CA3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1CA47-7CA3 is an operator panel belonging to the SIMATIC HMI OP 177B series, designed for machine-level human-machine interface applications. This unit is part of Siemens' SIMATIC HMI product line and provides a combined touch and key-based interface for process visualization and control. The OP 177B series is engineered for demanding industrial environments where reliable operator interaction is essential.

    The 6AV6355-1CA47-7CA3 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), supporting up to 256 colors. It is equipped with both a resistive touch screen and membrane function keys, providing flexible operator input options. The panel supports MPI, PROFIBUS DP, and RS-422/RS-485 communication interfaces, enabling integration with a wide range of Siemens and third-party controllers. It operates on a 24 V DC supply and is configured using WinCC flexible engineering software.

    The OP 177B is widely deployed in manufacturing, automotive, food and beverage, and process industries for local machine control and monitoring tasks. Its compact panel-mount design and dual-interface capability make it suitable for integration into control cabinets and machine panels where space is limited. The combination of touch and key input, along with robust communication options, makes it appropriate for applications requiring both intuitive operation and precise key-based control.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color
    Display Colors 256 colors
    Touch Technology Resistive touchscreen
    Input Keys Membrane function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, RS-422/RS-485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected on startup; the loaded project is incompatible or corrupt.
    Reload the project using WinCC flexible. Verify the project was compiled for the correct HMI device type and firmware version.
    Event ID: 20000
    Communication error with the configured PLC or controller; connection cannot be established.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI configuration.
    Event ID: 40000
    Tag read/write error; the HMI cannot access a configured PLC tag.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program for address changes.
    Event ID: 50000
    Recipe data error; recipe records cannot be read from or written to the storage medium.
    Check available memory on the internal flash or connected memory card. Reformat the memory card if necessary and re-transfer recipe data.
    Event ID: 60000
    Alarm buffer overflow; the number of pending alarms exceeds the buffer capacity.
    Acknowledge and clear active alarms. Review alarm configuration to reduce simultaneous alarm triggers or increase buffer size in the project settings.
    Event ID: 70000
    System memory low; available runtime memory is insufficient for current operations.
    Reduce the number of active screens, animations, or simultaneous processes. Simplify the project configuration and reload the optimized project.
    Event ID: 80000
    Firmware update error; firmware transfer was interrupted or the firmware file is invalid.
    Restart the firmware update procedure using ProSave or WinCC flexible. Ensure the correct firmware version for the 6AV6355-1CA47-7CA3 is used and the power supply is stable during transfer.

    Frequently Asked Questions

    What communication interfaces does the OP 177B 6AV6355-1CA47-7CA3 support?

    This panel supports MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, allowing connection to Siemens S7-300, S7-400, and compatible third-party controllers.

    Which engineering software is required to configure this HMI panel?

    The OP 177B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the device via MPI, PROFIBUS, or USB connection using ProSave or WinCC flexible.

    What is the operating voltage for the 6AV6355-1CA47-7CA3?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to prevent operational faults.

    Is the OP 177B compatible with S7-1200 or S7-1500 PLCs?

    The OP 177B is primarily designed for use with S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Compatibility with S7-1200 and S7-1500 is limited and generally not recommended; TIA Portal-based HMI panels are preferred for those controllers.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check that the voltage is within the specified tolerance. Inspect the internal fuse if accessible.

    Correct any supply voltage issues. If the supply is confirmed good and the display remains blank, the internal power supply board or backlight inverter may require replacement or professional repair.

    HMI fails to establish communication with the PLC

    Verify the MPI or PROFIBUS cable is correctly connected and terminated at both ends. Check the HMI and PLC address settings in WinCC flexible and in the PLC hardware configuration.

    Correct address mismatches and ensure baud rates are consistent across all devices on the network. Replace the communication cable if continuity testing reveals a fault.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touchscreen is physically damaged or contaminated. Attempt to recalibrate the touchscreen through the HMI Control Panel in the Start Center menu.

    Clean the touchscreen surface with a soft, dry cloth. Perform a touchscreen calibration via the device's Start Center. If calibration fails repeatedly, the touchscreen assembly may need replacement.

    Project transfer from WinCC flexible fails or times out

    Verify the communication cable and interface settings in WinCC flexible match the physical connection (MPI address, baud rate, or USB driver installation). Confirm the HMI is in Transfer mode.

    Set the HMI to Transfer mode via the Start Center. Reinstall the PC adapter driver if using an MPI/USB adapter. Try transferring via an alternative interface if available.

    HMI displays 'No project' or boots to Start Center after power cycle

    The internal flash memory may have been corrupted, or the project was not fully transferred. Check the last transfer log in WinCC flexible for errors.

    Re-transfer the compiled project to the HMI using WinCC flexible or ProSave. If the problem persists, perform a factory reset via the Start Center and re-transfer the project and firmware.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart