Siemens 6AV6355-1AA47-7DJ1 OP 77A
€ 531,00
The Siemens 6AV6355-1AA47-7DJ1 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling automated processes. This unit is part of the SIMATIC HMI Basic Panels generation, offering reliable operation in industrial environments.
The OP 77A features a monochrome LCD display with a resolution suitable for text and simple graphic representation, along with a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers a compact, panel-mount form factor with a protection rating of IP65 on the front face, making it resistant to dust and water ingress in typical machine environments.
This operator panel is widely used in manufacturing, packaging, and process automation applications where a cost-effective, robust HMI solution is required at the machine level. It is particularly suited for small to medium-scale automation tasks where text-based status displays, alarm messages, and simple parameter entry are the primary operator interface requirements. Industries such as food and beverage, automotive assembly, and general machine building commonly deploy this panel type.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 4 inches |
| Communication Interface | MPI / PROFIBUS DP |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 5 W |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 %, non-condensing |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2005 or higher |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect the communication cable for damage or loose connectors. Verify bus termination at both ends of the network. Check for address conflicts on the MPI or PROFIBUS network. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the panel.
Verify the PC-to-panel connection cable is intact. Ensure WinCC flexible is set to the correct transfer mode and the panel is in transfer mode. Check that the project is compiled without errors before downloading. - Event ID: 40000
- System memory low. The panel is running low on available runtime memory.
Reduce the number of active alarms or data records stored on the device. Simplify the project configuration and re-download. Consider archiving historical data externally. - Event ID: 50000
- Configuration error detected. The loaded project contains settings incompatible with the panel hardware.
Verify the project was compiled for the correct panel type (OP 77A). Re-compile and re-download the project using WinCC flexible. Perform a factory reset if the error persists. - Event ID: 70010
- Internal device error or hardware fault detected on the panel.
Cycle power to the panel. If the error persists, perform a factory reset via the panel's start center menu. If unresolved, the unit may require repair or replacement.
Frequently Asked Questions
Which PLCs are compatible with the Siemens 6AV6355-1AA47-7DJ1 OP 77A?
The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. Compatibility with other controllers may be possible depending on the available drivers in WinCC flexible.
What software is required to configure the OP 77A panel?
The panel is configured using Siemens WinCC flexible 2005 or a later version. The project is compiled on a PC and downloaded to the panel via a PC/PPI cable or MPI adapter.
What is the supply voltage for the 6AV6355-1AA47-7DJ1?
The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI panels in this series.
What is the front panel protection rating of the OP 77A?
The front face of the OP 77A carries an IP65 protection rating, making it suitable for environments where dust and water splashing may occur.
Can the OP 77A be used as a replacement for older SIMATIC OP panels?
In many cases, the OP 77A can serve as a functional replacement for older SIMATIC OP7 or OP17 panels, provided the communication interface and project configuration are adapted accordingly using WinCC flexible.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel's power connector using a multimeter. Verify polarity is correct and the supply is within tolerance.
Ensure the 24 V DC supply is stable and correctly wired. If the supply is confirmed good and the display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair.
Panel shows 'No connection to PLC' or communication error on startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment.
Correct any loose or damaged cable connections. Ensure the PLC station address in the HMI project matches the actual PLC configuration. Confirm the PLC is powered on and in RUN mode before the panel attempts to connect.
Project download fails or transfer does not complete
Confirm the panel is set to transfer mode via the start center menu. Check the PC-to-panel cable (PC/PPI or MPI adapter) for faults and verify the correct COM port is selected in WinCC flexible.
Place the panel in transfer mode, select the correct interface in WinCC flexible, and retry the download. Replace the transfer cable if communication cannot be established. Ensure the project compiles without errors prior to transfer.
Keypad buttons are unresponsive or intermittently fail
Inspect the membrane keypad for physical damage, contamination, or wear. Check whether the issue is limited to specific keys or affects all keys.
Clean the keypad surface with a dry cloth. If specific keys have failed due to wear or damage, the membrane keypad assembly may need to be replaced. Contact a qualified repair technician for internal keypad replacement.
Panel repeatedly restarts or enters an error loop
Check the 24 V DC supply for voltage dips or instability under load. Review the event log in the panel's start center for stored fault codes.
Stabilize the power supply, ensuring it is adequately rated for the panel's power consumption. If a corrupted project is suspected, perform a factory reset and re-download a freshly compiled project from WinCC flexible.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page