• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7DJ0 OP 77A
    Awaiting product image

    Siemens 6AV6355-1AA47-7DJ0 OP 77A

    € 955,52

    Reset
    Clear
    SKU: 6AV6355-1AA47-7DJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7DJ0 is an operator panel belonging to the SIMATIC HMI OP 77A series, manufactured by Siemens. It is a compact, key-operated panel designed for machine-level human-machine interface applications, providing operators with a straightforward means of monitoring and controlling industrial processes. This unit is part of the SIMATIC HMI product line, which is widely deployed across automation environments using Siemens SIMATIC controllers.

    The OP 77A features a monochrome LCD display and a membrane keypad with function keys, system keys, and numeric entry keys for direct operator input without a touchscreen. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. Configuration is performed using Siemens WinCC flexible software, and the panel includes internal flash memory for project storage. The unit operates on a 24 V DC supply and is rated to IP65 at the front panel, making it suitable for panel-mount installation in industrial enclosures.

    The OP 77A is typically used in machine building, manufacturing automation, and process control applications where a cost-effective, robust operator interface is required. It is well suited for tasks such as parameter entry, alarm display, and status monitoring on standalone machines or production lines. Industries including automotive, food and beverage, packaging, and general manufacturing commonly deploy this panel as a local operator station on SIMATIC-controlled equipment.

    Technical Specifications

    Display Type Monochrome LCD
    Display Size 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    Configuration Software WinCC flexible 2005 or higher
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mount
    Certifications CE, UL, cULus
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected on startup; project data in flash memory is corrupt or missing.
    Re-download the project from WinCC flexible to the panel and verify the transfer connection.
    Event ID: 20000
    Communication link to the PLC has been interrupted or cannot be established.
    Check MPI/PROFIBUS DP cable connections, verify bus address settings, and confirm PLC is powered and communicating.
    Event ID: 40000
    Operating system error; internal firmware fault detected.
    Perform a panel reset. If the fault persists, update the firmware using ProSave or WinCC flexible.
    Event ID: 50000
    Transfer mode active; panel is waiting for a project download.
    Initiate project transfer from WinCC flexible, or restart the panel in normal operating mode if transfer is not intended.
    Event ID: 60000
    Tag communication error; a configured tag cannot be read from or written to the connected controller.
    Verify tag addresses in the WinCC flexible project match the PLC data blocks. Check communication settings and cable integrity.
    Event ID: 70000
    Memory overflow; available flash memory is insufficient for the current project.
    Reduce project size by removing unused screens, graphics, or recipes, then re-transfer the project.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77A (6AV6355-1AA47-7DJ0)?

    The OP 77A is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with certain SIMATIC S5 controllers depending on the configuration.

    What software is required to configure this operator panel?

    The OP 77A is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via the MPI interface or a direct PC adapter connection.

    What is the supply voltage for the 6AV6355-1AA47-7DJ0?

    The panel requires a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid damage or operational faults.

    Is the OP 77A panel suitable for outdoor installation?

    The front panel is rated IP65, providing protection against dust and water jets, but the unit is not rated for direct outdoor exposure. It should be installed in a suitable enclosure if used in harsh environments.

    Does the OP 77A support recipe management or data logging?

    The OP 77A supports basic recipe management functions through WinCC flexible. Full data logging and trending capabilities are limited compared to higher-end SIMATIC HMI panels such as the TP or MP series.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified range and that the connector is fully seated.

    Restore correct supply voltage if out of range. If voltage is correct and display remains blank, the internal power supply or backlight may be faulty and the unit should be sent for repair or replacement.

    Panel cannot establish communication with the PLC

    Verify the MPI or PROFIBUS DP cable is correctly wired and terminated. Check that the bus address configured on the panel matches the project settings and does not conflict with other devices on the bus.

    Correct any wiring faults or termination issues. Adjust the bus address on the panel via the start center settings and ensure the PLC program is configured with the correct HMI connection parameters.

    Project transfer from WinCC flexible fails or times out

    Check the PC adapter or MPI cable connection between the engineering PC and the panel. Confirm the panel is in transfer mode and that the correct COM port and transfer rate are selected in WinCC flexible.

    Switch the panel to transfer mode via the start center menu. Verify PC adapter drivers are installed correctly and select the matching baud rate in the WinCC flexible transfer settings.

    Operator keys are unresponsive or register incorrect inputs

    Inspect the membrane keypad for physical damage, contamination, or deformation. Test individual keys using the panel's built-in key test function available in the start center.

    Clean the keypad surface with a dry cloth. If keys remain unresponsive after cleaning, the membrane keypad assembly is likely worn or damaged and requires replacement.

    Panel repeatedly displays communication error messages during operation

    Monitor the PROFIBUS DP or MPI bus for noise or signal integrity issues. Check cable lengths, shielding, and termination resistors at both ends of the bus segment.

    Replace or re-route cables that are damaged or running parallel to high-voltage conductors. Ensure bus termination is active only at the physical ends of the bus segment and that cable lengths do not exceed the specified maximum for the selected baud rate.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart