• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6355-1AA47-7DB2 OP 177B
    Awaiting product image

    Siemens 6AV6355-1AA47-7DB2 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6355-1AA47-7DB2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6355-1AA47-7DB2 is an operator panel belonging to the SIMATIC HMI OP 177B series, part of Siemens' established line of panel-based human-machine interface devices. This unit provides a monochrome or color display interface for machine-level visualization and control, designed to integrate seamlessly within SIMATIC automation environments. The OP 177B series is engineered for demanding industrial conditions and is intended for use as a standalone operator panel connected to SIMATIC S7 PLCs and other compatible controllers.

    The OP 177B features a 5.7-inch STN display and supports both MPI/PROFIBUS DP and Ethernet communication interfaces, enabling flexible integration into existing network architectures. The panel is configured using Siemens WinCC flexible engineering software, allowing the creation of process screens, alarm management, trend displays, and recipe handling. It offers a membrane keypad with function keys for operator input, onboard flash memory for project storage, and supports multiple language configurations for international deployments. The unit operates on a 24 V DC supply and meets relevant CE and UL certification requirements.

    The OP 177B is widely deployed in machine automation, packaging machinery, conveyor systems, and process plant environments where a robust, panel-mounted HMI is required. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a common choice for retrofit and new-build machine control panels. The panel's compact form factor and front-face IP65 protection rating make it suitable for installation in control cabinet doors in environments with exposure to dust and water spray.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI/PROFIBUS DP, Ethernet (RJ45)
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC HMI OP 177B
    Engineering Software WinCC flexible 2008 or later

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC could not be established or was interrupted during operation.
    Check MPI/PROFIBUS DP or Ethernet cable connections and verify PLC address settings in the project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout occurred between the HMI panel and the configured controller.
    Verify network cable integrity, check baud rate and station address settings on both the HMI and PLC. Restart both devices if the issue persists.
    Event ID: 20000
    Project download failed or project data on the panel is corrupt or missing.
    Re-download the project from WinCC flexible to the panel via Ethernet or MPI. Ensure the WinCC flexible version matches the panel firmware version.
    Event ID: 40000
    Panel operating system or firmware version mismatch detected.
    Update the panel firmware using the Siemens ProSave tool or via WinCC flexible to match the version required by the project.
    Event ID: 50000
    Internal flash memory error or project storage fault detected.
    Perform a panel reset to factory defaults using the Control Panel in the Start Center, then re-download the project. If the fault persists, the panel may require servicing.
    Event ID: 60000
    Screen saver or backlight timeout has activated, display appears blank.
    Press any function key or touch the keypad to wake the display. Adjust the screen saver timeout settings in the panel Control Panel if required.
    Event ID: 70000
    Recipe data read/write error occurred during recipe transfer between HMI and PLC.
    Check recipe configuration in WinCC flexible, verify PLC data block addresses are correct and accessible, and ensure sufficient memory is available on the panel.

    Frequently Asked Questions

    What communication interfaces does the OP 177B (6AV6355-1AA47-7DB2) support?

    The OP 177B supports MPI and PROFIBUS DP interfaces as well as an Ethernet (RJ45) port, allowing connection to SIMATIC S7 PLCs and other compatible controllers over multiple network types.

    Which engineering software is used to configure this panel?

    The panel is configured using Siemens WinCC flexible. The project is created on a PC and downloaded to the panel via Ethernet or MPI connection.

    What is the supply voltage for the 6AV6355-1AA47-7DB2?

    The panel operates on a 24 V DC supply voltage, which is the standard supply used across the SIMATIC HMI panel range.

    Is the OP 177B compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the OP 177B is fully compatible with SIMATIC S7-300 and S7-400 controllers via MPI, PROFIBUS DP, or Ethernet, and can also communicate with S7-1200 controllers via Ethernet with appropriate driver configuration.

    What is the front-face protection rating of this panel?

    The front face of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments with dust and water spray exposure when correctly panel-mounted with the supplied seal.

    Troubleshooting

    Display remains blank after power is applied

    Check that 24 V DC is present at the power supply terminals. Verify that the screen saver has not activated. Inspect the internal backlight by listening for the startup chime or checking if the Start Center appears briefly.

    Restore 24 V DC supply if absent. If the backlight has failed, the panel will require backlight or display replacement. If the screen saver is active, press any key to wake the display.

    Panel fails to communicate with the PLC after startup

    Verify the MPI or PROFIBUS DP address configured in the HMI project matches the physical address set on the PLC. Check cable connections and termination resistors on the PROFIBUS network. For Ethernet, verify IP address settings on both devices.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged cables and ensure correct bus termination. Confirm Ethernet IP addresses are on the same subnet.

    Project download from WinCC flexible fails or is interrupted

    Check the USB or Ethernet connection between the engineering PC and the panel. Verify that the WinCC flexible version is compatible with the panel firmware version. Ensure the panel is in Transfer mode via the Start Center.

    Switch the panel to Transfer mode manually from the Start Center. Update panel firmware using ProSave if a version mismatch exists. Use a direct Ethernet cable or known-good MPI adapter for the download.

    Touchscreen or keypad inputs are not responding correctly

    Check whether the function keys are physically damaged or contaminated. For touch-enabled variants, verify that the touch calibration has not drifted. Inspect for moisture ingress behind the front panel membrane.

    Perform a touch recalibration from the panel Control Panel settings. Clean the membrane keypad surface. If physical damage or moisture ingress is confirmed, the front panel assembly will require replacement.

    Panel repeatedly restarts or enters a boot loop

    This may indicate a corrupt project file, a firmware fault, or a hardware fault on the main board. Check whether the panel reaches the Start Center before restarting, which would indicate a project-level issue rather than a hardware fault.

    Boot into the Start Center and delete the existing project, then re-download a known-good project from WinCC flexible. If the restart loop occurs before the Start Center loads, perform a firmware recovery using ProSave. If the fault persists, the panel requires hardware inspection.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart