Siemens 6AV6355-1AA47-7DC0 OP 77A
€ 955,52
The Siemens 6AV6355-1AA47-7DC0 is an operator panel belonging to the SIMATIC HMI OP 77A series, designed for human-machine interface applications in industrial automation environments. This compact panel provides a keypad-based interface for process visualization and operator control, and is part of Siemens' established SIMATIC HMI product line. It is intended for use with Siemens SIMATIC S7 and S5 controllers as well as third-party PLCs via standard communication protocols.
The OP 77A features a monochrome LCD display with a resolution suitable for displaying text and simple graphics, along with a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration into Siemens automation networks. The panel is configured using Siemens ProTool or WinCC flexible engineering software, and supports alarm management, recipe handling, and trend display functions. The unit is rated for industrial environments with an IP65 protection rating on the front face.
The OP 77A is widely deployed in manufacturing, process automation, and machine building applications where a cost-effective, robust operator interface is required. It is commonly found on packaging machinery, conveyor systems, and general-purpose industrial machines. Its compact form factor and keypad-based operation make it suitable for environments where touchscreen interfaces are impractical due to contamination or operator glove use.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 4 inches (diagonal) |
| Communication Interface | MPI, PROFIBUS DP |
| Input/Operating Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Engineering Software | ProTool, WinCC flexible |
| Series/Product Family | SIMATIC HMI OP 77A |
Common Error Codes and System Events
- Event ID: 1000
- System startup completed successfully. The panel has initialized and established communication with the configured controller.
No action required. This is an informational event confirming normal startup. - Event ID: 10000
- Connection to PLC lost. The panel cannot establish or maintain communication with the configured controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC is powered and running. Check configured station address matches the PLC. - Event ID: 10001
- Communication timeout. The panel did not receive a response from the controller within the configured timeout period.
Verify network cabling integrity. Check for address conflicts on the MPI or PROFIBUS network. Reduce network load or increase timeout setting in project configuration. - Event ID: 20000
- Tag read error. The panel was unable to read the value of a configured process tag from the controller.
Verify the tag address is correct in the project configuration. Confirm the data block or memory area exists in the PLC program. Re-download the project if necessary. - Event ID: 40000
- Project download error. A project transfer to the panel was interrupted or failed.
Check the transfer cable connection. Ensure the panel is in transfer mode before initiating download. Retry the download from WinCC flexible or ProTool. - Event ID: 50000
- Internal device error. A hardware or firmware fault has been detected within the panel.
Cycle power to the panel. If the error persists, perform a factory reset. Contact Siemens technical support or arrange for unit repair if the fault remains after reset. - Event ID: 60000
- Configuration memory error. The panel detected a checksum error or corruption in the stored project data.
Re-download the project from the engineering station. If the error recurs, the internal flash memory may be faulty and the unit should be repaired or replaced.
Frequently Asked Questions
What communication interfaces does the OP 77A support?
The OP 77A supports MPI and PROFIBUS DP communication interfaces, allowing direct connection to Siemens S7 controllers and other PROFIBUS-compatible devices.
Which engineering software is used to configure the 6AV6355-1AA47-7DC0?
The panel is configured using Siemens ProTool or WinCC flexible software. Projects are downloaded to the panel via the MPI interface or a dedicated transfer cable.
What is the supply voltage for this operator panel?
The OP 77A requires a 24 V DC supply voltage for operation.
Is the OP 77A compatible with third-party PLCs?
Yes, the OP 77A can communicate with third-party controllers that support PROFIBUS DP, in addition to native Siemens S7 and S5 systems.
What is the front panel protection rating of the OP 77A?
The front panel of the OP 77A carries an IP65 protection rating, making it suitable for environments with dust and water spray.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for correct polarity. Inspect the internal fuse if accessible.
Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuse with the correct rating. If the supply is correct and the display remains blank, the internal power supply or display backlight may be faulty and the unit should be sent for repair.
Panel displays 'No connection to PLC' or communication error on startup
Check the MPI or PROFIBUS DP cable between the panel and the controller. Verify the station address configured in the project matches the physical PLC address. Confirm the PLC is powered and in RUN or STOP mode.
Replace or reseat the communication cable. Correct the station address in the project and re-download. Check PROFIBUS termination at both ends of the network segment.
Project download fails or transfer does not start
Confirm the panel is set to transfer mode before initiating the download from the engineering PC. Check the transfer cable or MPI adapter connection. Verify the correct communication port and baud rate are selected in WinCC flexible or ProTool.
Restart the panel in transfer mode by holding the appropriate key combination during boot. Reseat the transfer cable. Select the correct COM port and baud rate in the engineering software and retry the download.
Operator keys are unresponsive or register incorrect inputs
Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key systematically using the panel's built-in key test function if available in the service menu.
Clean the keypad surface with a dry cloth. If individual keys are damaged or non-functional, the membrane keypad assembly should be replaced. This typically requires disassembly of the front housing.
Panel repeatedly restarts or enters a boot loop
Check the supply voltage for stability and ripple. Inspect the project stored on the panel for corruption by attempting to re-download a known good project. Note any error codes displayed during the boot sequence.
Stabilize the 24 V DC power supply. Re-download the project from the engineering station. If the boot loop continues after a fresh project download, the internal flash memory or main board may be faulty and the unit requires repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page