Siemens 6AV6341-1EC34-0BY0 OP 77B
€ 1.995,00
The Siemens 6AV6341-1EC34-0BY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. This compact panel is designed for straightforward machine-level operator control and monitoring tasks, providing a reliable human-machine interface solution for industrial automation environments. It is manufactured by Siemens as part of the broader SIMATIC HMI portfolio, which integrates seamlessly with SIMATIC S7 PLCs and other Siemens automation systems.
The OP 77B features a 4-line text display capable of showing alphanumeric characters, with a membrane keypad for operator input including function keys and system keys. It supports MPI and PROFIBUS DP communication interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and offers basic alarm management, recipe handling, and message display capabilities within a compact and robust housing.
The OP 77B is widely used in manufacturing, packaging, and process automation applications where a cost-effective, text-based operator interface is sufficient. It is particularly suited for machine-level control panels in industries such as food and beverage, automotive assembly, and general factory automation. Its compact form factor and simple keypad interface make it appropriate for installations where space is limited and the operator interaction requirements are straightforward.
Technical Specifications
| Display Type | STN LCD, 4-line text display |
|---|---|
| Display Characters | 4 lines x 20 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 4.5 W |
| Communication Interface | MPI, PROFIBUS DP |
| Configuration Software | WinCC flexible 2005 or higher |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI Basic Panels / OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP 77B and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to the PLC was interrupted during operation.
Inspect physical cable integrity and connector seating. Check for address conflicts on the MPI or PROFIBUS network. Restart the panel and PLC if the connection does not recover automatically. - Event ID: 20000
- Configuration or project data on the panel is corrupted or missing.
Re-transfer the project from WinCC flexible to the panel. Ensure the correct project version is used and the transfer completes without errors. - Event ID: 40000
- Internal device error detected on the OP 77B.
Perform a panel restart. If the error persists, perform a factory reset and re-transfer the project. Contact Siemens technical support if the fault remains after reset. - Event ID: 50000
- Alarm buffer overflow. The number of pending alarms has exceeded the panel's buffer capacity.
Acknowledge and clear existing alarms on the panel. Review the alarm configuration in WinCC flexible to reduce unnecessary alarm generation or increase acknowledgement frequency. - Event ID: 60000
- Recipe data error. A recipe record could not be read or written correctly.
Check the recipe configuration in WinCC flexible for consistency. Verify that the PLC data blocks referenced by the recipe are correctly defined and accessible.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B?
The OP 77B supports SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with SIMATIC S7-1200 and S7-1500 via PROFIBUS DP in some configurations.
What software is required to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via the MPI interface or a PC adapter cable.
What is the supply voltage for the 6AV6341-1EC34-0BY0?
The panel operates on 24 V DC. The supply must be within the specified tolerance range to ensure reliable operation.
What is the front panel protection rating of the OP 77B?
The front panel of the OP 77B carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
Does the OP 77B support touch input?
No, the OP 77B does not have a touchscreen. Operator input is performed exclusively via the integrated membrane keypad, which includes function keys and system navigation keys.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel's power connector using a multimeter. Verify that the supply is within the specified voltage range and that the connector is firmly seated.
Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair or replacement.
Panel shows 'No connection to PLC' message
Verify the MPI or PROFIBUS DP cable is correctly connected and that termination resistors are properly placed at both ends of the bus. Check that the PLC address configured in WinCC flexible matches the actual PLC station address.
Correct any wiring faults, replace damaged cables, and ensure bus termination is correct. Update the WinCC flexible project with the correct PLC address and re-transfer to the panel if necessary.
Panel does not accept project transfer from PC
Confirm that the PC adapter or MPI cable is correctly connected and that the correct COM port and transfer speed are selected in WinCC flexible. Check that the panel is in transfer mode.
Set the panel to transfer mode via the panel's start center menu. Ensure the baud rate in WinCC flexible matches the panel setting. Replace the PC adapter cable if communication still cannot be established.
Function keys do not respond to presses
Inspect the membrane keypad for physical damage, contamination, or deformation. Verify in the WinCC flexible project that the function keys are correctly assigned to screen objects or PLC tags.
Clean the keypad surface if contaminated. If keys are physically damaged, the keypad membrane may need replacement. Review and correct function key assignments in the WinCC flexible project and re-transfer.
Alarms are displayed but cannot be acknowledged
Check the alarm configuration in WinCC flexible to confirm that an acknowledgement button or key is correctly assigned. Verify that the corresponding PLC bit for alarm acknowledgement is writable and not locked by the PLC program.
Correct the acknowledgement key assignment in WinCC flexible and re-transfer the project. Ensure the PLC program allows the acknowledgement bit to be set by the HMI panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page