• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1EC24-0BY0 OP27
    Awaiting product image

    Siemens 6AV6341-1EC24-0BY0 OP27

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1EC24-0BY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1EC24-0BY0 is an Operator Panel (OP27) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a monochrome graphical display for process visualization, operator control, and status monitoring. It is part of the OP27 series, which is a well-established panel in Siemens' portfolio for machine-level HMI tasks.

    The OP27 features a 5.7-inch STN monochrome LCD display with a resolution of 320 x 240 pixels (QVGA), supporting up to 8 shades of gray. It communicates via MPI (Multi-Point Interface) and PROFIBUS-DP, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keyboard with function keys, numeric keys, and system keys for operator input. Configuration is performed using ProTool software, and the unit supports recipe management, trend displays, alarm logging, and message archiving within its onboard memory.

    The OP27 is widely used in machine building, process automation, and manufacturing industries where a compact, robust operator interface is required at the machine level. It is suitable for applications such as packaging machinery, conveyor systems, press controls, and general-purpose machine tools. Its compatibility with the SIMATIC S7 PLC family makes it a standard choice for Siemens-based automation architectures.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors 8 shades of gray
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 15 W
    Communication Interface MPI, PROFIBUS-DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP27
    Configuration Software ProTool

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP27 and the connected PLC. The connection to the configured controller cannot be established or has been lost.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the PLC address settings match the OP27 configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Timeout error on the communication bus. The OP27 did not receive a response from the PLC within the expected time frame.
    Check bus cable integrity and connector pins. Verify bus termination at both ends of the network. Reduce bus length or check for electromagnetic interference sources.
    Event ID: 20000
    Configuration error detected. The project loaded on the OP27 is incompatible with the current firmware version or hardware.
    Reload the project using ProTool with a compatible version. Verify firmware version on the OP27 and update if necessary.
    Event ID: 40000
    Internal memory error. The OP27 has detected a fault in its internal data memory, which may affect recipe or alarm data storage.
    Perform a memory reset via the OP27 service menu. Reload the project configuration. If the error persists, the unit may require hardware repair or replacement.
    Event ID: 50000
    Operating system error. An internal software fault has been detected in the OP27 operating system.
    Cycle power to the OP27. If the fault recurs, perform a complete firmware reload using the appropriate Siemens transfer tool.
    Event ID: 60000
    Display or backlight fault. The OP27 display is not functioning correctly or the backlight has failed.
    Check the 24 V DC supply voltage at the power connector. If supply is correct, the backlight or display module may require replacement.
    Event ID: 70000
    Keyboard or input device fault. One or more keys on the membrane keyboard are not responding or are registering continuous input.
    Inspect the membrane keyboard for physical damage or contamination. Clean the keyboard surface. If the fault persists, the membrane keyboard assembly may need replacement.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP27 (6AV6341-1EC24-0BY0)?

    The OP27 is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with SIMATIC S5 controllers using appropriate adapters.

    What software is used to configure the OP27?

    The OP27 is configured using Siemens ProTool software. Projects created in ProTool are transferred to the panel via the MPI interface or a serial PC/PPI cable.

    What is the supply voltage for the OP27?

    The OP27 requires a 24 V DC power supply. The acceptable voltage range is typically 18 V DC to 30 V DC.

    What is the IP protection rating of the OP27 front panel?

    The front panel of the OP27 is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for panel-mounted industrial environments.

    Can the OP27 store recipes and alarm logs?

    Yes, the OP27 supports recipe management and alarm logging using its onboard memory. Data can be stored and retrieved during operation without requiring an external memory card for basic functions.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the unit. Check for blown internal fuses. Observe whether the unit emits any startup sounds or keyboard LED activity.

    Ensure the supply voltage is within the 18–30 V DC range. Replace any blown internal fuses. If the backlight is faulty but the unit is otherwise operational, the backlight or inverter board requires replacement.

    OP27 fails to communicate with the S7 PLC

    Verify the MPI or PROFIBUS-DP address configured in the ProTool project matches the physical address set on the PLC. Check cable connections, termination resistors at both ends of the bus, and cable continuity.

    Correct any address mismatches in the ProTool project and retransfer the configuration. Replace damaged cables or connectors. Ensure bus termination resistors are correctly installed at the first and last nodes on the network.

    Project transfer from PC to OP27 fails

    Check the serial or MPI cable connection between the PC and the OP27. Verify that the OP27 is in transfer mode and that the correct COM port and transfer settings are selected in ProTool.

    Place the OP27 in transfer mode via the startup menu. Confirm the correct interface and baud rate settings in ProTool. Try a different cable or PC port if the issue persists.

    Membrane keyboard keys are unresponsive or register incorrect input

    Inspect the keyboard surface for physical damage, contamination, or deformation. Test individual keys in the OP27 diagnostics or service menu if available.

    Clean the keyboard surface with a dry cloth. If specific keys are permanently actuated or non-functional, the membrane keyboard overlay assembly requires replacement.

    OP27 displays a communication timeout alarm repeatedly during operation

    Monitor the MPI or PROFIBUS-DP bus for intermittent disconnections. Check for loose connectors, damaged cable shielding, or sources of electromagnetic interference near the bus cable.

    Secure all bus connectors and verify cable shielding is properly grounded. Reroute the bus cable away from high-voltage or high-current conductors. Replace damaged cable segments.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart