• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1FC14-0AY0 OP 77A
    Awaiting product image

    Siemens 6AV6341-1FC14-0AY0 OP 77A

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1FC14-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1FC14-0AY0 is an OP 77A operator panel belonging to the SIMATIC HMI Basic Panels product family. This compact panel-mount operator terminal provides a monochrome display interface for machine-level human-machine interaction and is designed for use with Siemens SIMATIC S7 PLCs. It is part of the broader SIMATIC HMI portfolio and is configured using WinCC flexible software.

    The OP 77A features a 4-line text display capable of showing alphanumeric characters, function keys, and a membrane keypad for operator input. It supports MPI and PROFIBUS DP communication interfaces for direct connection to SIMATIC S7-200, S7-300, and S7-400 controllers. The unit operates on a 24 V DC supply and is built to industrial standards with a protection rating of IP65 on the front panel, making it suitable for panel-mount installations in demanding environments.

    The OP 77A is widely used in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required for displaying process values, alarms, and operator prompts. It is commonly found on packaging machinery, conveyor systems, and general-purpose industrial machines where a full graphical display is not required but reliable text-based operator interaction is essential.

    Technical Specifications

    Display Type Monochrome LCD, 4-line text display
    Display Characters 4 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption 3.6 W (typical)
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Mounting Panel mount
    Certifications CE, UL
    Configuration Software WinCC flexible 2008 or higher
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 77A and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration in WinCC flexible.
    Event ID: 10001
    Timeout error on the communication bus. The PLC did not respond within the expected time window.
    Check the physical bus cable for breaks or poor connections. Verify the PLC is in RUN mode and the network address is correctly configured.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel.
    Verify the PC-to-panel connection (MPI or USB adapter). Ensure the WinCC flexible project is compiled without errors before downloading.
    Event ID: 40000
    System memory error. Internal memory fault detected during startup or operation.
    Perform a factory reset of the panel. If the fault persists, the internal memory may be corrupted and the unit should be serviced or replaced.
    Event ID: 50000
    Configuration mismatch. The loaded project is not compatible with the panel firmware version.
    Update the panel firmware using WinCC flexible or ProSave tool, then re-download the project to the panel.
    Event ID: 60000
    Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the permissible operating range.
    Measure the supply voltage at the panel connector. Ensure the power supply output is within the specified 24 V DC range and check wiring for voltage drop.

    Frequently Asked Questions

    Which communication interfaces does the OP 77A (6AV6341-1FC14-0AY0) support?

    The OP 77A supports MPI and PROFIBUS DP interfaces, allowing direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs without an additional communication module.

    What software is used to configure the OP 77A?

    The OP 77A is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via MPI or using a suitable PC adapter.

    What is the supply voltage for the 6AV6341-1FC14-0AY0?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid undervoltage faults.

    What is the front panel protection rating of the OP 77A?

    The front panel of the OP 77A carries an IP65 protection rating, making it suitable for panel-mount installations where dust and water spray protection is required.

    Is the OP 77A compatible with SIMATIC S7-1200 or S7-1500 controllers?

    The OP 77A was designed primarily for S7-200, S7-300, and S7-400 controllers via MPI and PROFIBUS DP. Compatibility with S7-1200 or S7-1500 is not supported, as those controllers use PROFINET and are intended for use with newer SIMATIC Basic or Comfort Panels.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector. Verify the supply polarity is correct and the voltage is within the specified range.

    Correct any wiring errors and ensure the power supply output is stable at 24 V DC. If the display remains blank with correct supply voltage, the internal power supply or display backlight may be faulty and the unit should be inspected or repaired.

    Panel shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the bus address and baud rate configured in WinCC flexible match the PLC settings.

    Replace or reseat the communication cable. Adjust the panel address and baud rate settings in the WinCC flexible project to match the PLC network configuration, then re-download the project.

    Project download fails from PC to panel

    Check the PC-to-panel connection using an MPI adapter or PC adapter. Ensure the correct COM port and transfer settings are selected in WinCC flexible or ProSave.

    Try a different MPI adapter or cable. Confirm the panel is in transfer mode before initiating the download. Recompile the WinCC flexible project and retry the transfer.

    Operator keys are unresponsive or produce incorrect input

    Inspect the membrane keypad for physical damage, contamination, or wear. Check if the issue is consistent across all keys or limited to specific keys.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the membrane keypad assembly may need replacement. Contact a qualified repair technician for keypad replacement.

    Panel repeatedly restarts or enters fault state on startup

    Check for undervoltage on the 24 V DC supply, especially under load. Review the event log on the panel for specific event IDs that indicate the cause of the restart.

    Stabilize the power supply and ensure adequate current capacity. If memory-related event codes are displayed, perform a factory reset using the panel startup menu. If the problem persists, the unit may require servicing.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart