
Siemens 6AV6341-1DC03-1AY0 OP 77B
€ 1.995,00
The Siemens 6AV6341-1DC03-1AY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is a compact, key-operated operator panel designed for machine-level visualization and control tasks in industrial automation environments. This unit is part of Siemens' established SIMATIC HMI portfolio and is configured and operated using WinCC flexible software.
The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for clear readability in varying ambient light conditions. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7 PLCs. The panel includes function keys and system keys for operator input, and supports recipe management, alarm logging, and trend display functions. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.
The OP 77B is widely used in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. It is particularly suited for integration with SIMATIC S7-200, S7-300, and S7-400 PLCs in applications such as packaging machinery, conveyor systems, and general-purpose industrial machines. Its compact form factor and robust construction make it appropriate for panel mounting in space-constrained control cabinets.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Resolution | 160 x 80 pixels |
| Display Size | 4 inch |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 4.5 W |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC flexible 2005 or higher |
| Series | SIMATIC HMI OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; the loaded project is incompatible with the panel firmware version.
Reload a compatible project using WinCC flexible. Ensure the firmware version matches the project settings and update firmware if necessary. - Event ID: 20000
- Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. - Event ID: 40000
- Tag read error; the panel cannot read a configured tag from the connected PLC.
Verify the PLC is in RUN mode and the tag address in the project is correct. Check communication link integrity. - Event ID: 50000
- Alarm buffer overflow; the number of pending alarms has exceeded the buffer capacity.
Acknowledge and clear existing alarms. Review alarm configuration to reduce unnecessary alarm triggers. - Event ID: 60000
- Recipe data error; a recipe record could not be read or written correctly.
Check recipe configuration in WinCC flexible. Verify that the associated PLC data blocks are correctly defined and accessible. - Event ID: 70000
- System memory low; available panel memory is insufficient for current operations.
Reduce the size of the loaded project, clear alarm logs, and remove unused recipes or trend data to free memory. - Event ID: 80000
- Backlight failure detected; the display backlight has reached end of life or has failed.
Replace the panel or arrange for backlight servicing. Continued operation may be possible but display visibility will be reduced.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.
What software is required to configure the 6AV6341-1DC03-1AY0?
The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via MPI cable or PROFIBUS connection.
What is the supply voltage for this operator panel?
The OP 77B operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range for reliable operation.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.
Does the OP 77B support recipe and alarm functions?
Yes, the OP 77B supports recipe management, alarm logging, and basic trend display functions, making it suitable for applications requiring operator data entry and process monitoring.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector. Verify that the supply is within tolerance and that the power connector is fully seated.
Restore correct 24 V DC supply. If voltage is correct and display remains blank, the backlight or internal power circuitry may have failed and the unit should be sent for repair or replacement.
Panel shows communication error or cannot connect to PLC
Inspect MPI or PROFIBUS DP cable for damage or loose connections. Verify that bus termination resistors are correctly installed at both ends of the bus. Check that the panel address and baud rate match the PLC configuration.
Replace or reseat the communication cable. Correct the bus address and baud rate settings in WinCC flexible and reload the project. Ensure only one active bus termination is present at each end of the network.
Project transfer fails from WinCC flexible to the panel
Confirm that the correct communication interface and panel address are selected in WinCC flexible transfer settings. Check that the MPI cable or PROFIBUS adapter is functioning correctly.
Set the panel to transfer mode via the Start Center menu. Verify cable and adapter driver installation on the PC. Retry the transfer with the correct interface settings selected in WinCC flexible.
Function keys do not respond to operator input
Check whether the panel is in the correct operating mode and that the project has been successfully loaded. Inspect the keypad membrane for physical damage or contamination.
Reload the project to ensure key assignments are correctly configured. If physical key damage is present, the operator panel membrane or unit will require replacement.
Alarm messages are not displayed on the panel
Verify that alarms are correctly configured in the WinCC flexible project and that the associated PLC tags are mapped to the correct addresses. Check that the PLC is generating the alarm trigger bits.
Review alarm configuration in WinCC flexible and confirm PLC tag addresses are correct. Reload the updated project to the panel and test alarm triggering from the PLC side.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page



