• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1DC03-1AY0 OP 77B
    Awaiting product image

    Siemens 6AV6341-1DC03-1AY0 OP 77B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1DC03-1AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1DC03-1AY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is a compact, key-operated operator panel designed for machine-level visualization and control tasks in industrial automation environments. This unit is part of Siemens' established SIMATIC HMI portfolio and is configured and operated using WinCC flexible software.

    The OP 77B features a monochrome STN LCD display with a resolution of 160 x 80 pixels and a backlit screen for clear readability in varying ambient light conditions. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7 PLCs. The panel includes function keys and system keys for operator input, and supports recipe management, alarm logging, and trend display functions. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The OP 77B is widely used in manufacturing, machine building, and process automation applications where a cost-effective, reliable operator interface is required at the machine level. It is particularly suited for integration with SIMATIC S7-200, S7-300, and S7-400 PLCs in applications such as packaging machinery, conveyor systems, and general-purpose industrial machines. Its compact form factor and robust construction make it appropriate for panel mounting in space-constrained control cabinets.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Resolution 160 x 80 pixels
    Display Size 4 inch
    Input Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher
    Series SIMATIC HMI OP 77B

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected during startup; the loaded project is incompatible with the panel firmware version.
    Reload a compatible project using WinCC flexible. Ensure the firmware version matches the project settings and update firmware if necessary.
    Event ID: 20000
    Communication error on MPI or PROFIBUS DP interface; connection to the PLC has been lost.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration.
    Event ID: 40000
    Tag read error; the panel cannot read a configured tag from the connected PLC.
    Verify the PLC is in RUN mode and the tag address in the project is correct. Check communication link integrity.
    Event ID: 50000
    Alarm buffer overflow; the number of pending alarms has exceeded the buffer capacity.
    Acknowledge and clear existing alarms. Review alarm configuration to reduce unnecessary alarm triggers.
    Event ID: 60000
    Recipe data error; a recipe record could not be read or written correctly.
    Check recipe configuration in WinCC flexible. Verify that the associated PLC data blocks are correctly defined and accessible.
    Event ID: 70000
    System memory low; available panel memory is insufficient for current operations.
    Reduce the size of the loaded project, clear alarm logs, and remove unused recipes or trend data to free memory.
    Event ID: 80000
    Backlight failure detected; the display backlight has reached end of life or has failed.
    Replace the panel or arrange for backlight servicing. Continued operation may be possible but display visibility will be reduced.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 77B panel?

    The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.

    What software is required to configure the 6AV6341-1DC03-1AY0?

    The OP 77B is configured using Siemens WinCC flexible 2005 or a later version. Projects are transferred to the panel via MPI cable or PROFIBUS connection.

    What is the supply voltage for this operator panel?

    The OP 77B operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range for reliable operation.

    What is the front panel protection rating of the OP 77B?

    The front face of the OP 77B is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    Does the OP 77B support recipe and alarm functions?

    Yes, the OP 77B supports recipe management, alarm logging, and basic trend display functions, making it suitable for applications requiring operator data entry and process monitoring.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector. Verify that the supply is within tolerance and that the power connector is fully seated.

    Restore correct 24 V DC supply. If voltage is correct and display remains blank, the backlight or internal power circuitry may have failed and the unit should be sent for repair or replacement.

    Panel shows communication error or cannot connect to PLC

    Inspect MPI or PROFIBUS DP cable for damage or loose connections. Verify that bus termination resistors are correctly installed at both ends of the bus. Check that the panel address and baud rate match the PLC configuration.

    Replace or reseat the communication cable. Correct the bus address and baud rate settings in WinCC flexible and reload the project. Ensure only one active bus termination is present at each end of the network.

    Project transfer fails from WinCC flexible to the panel

    Confirm that the correct communication interface and panel address are selected in WinCC flexible transfer settings. Check that the MPI cable or PROFIBUS adapter is functioning correctly.

    Set the panel to transfer mode via the Start Center menu. Verify cable and adapter driver installation on the PC. Retry the transfer with the correct interface settings selected in WinCC flexible.

    Function keys do not respond to operator input

    Check whether the panel is in the correct operating mode and that the project has been successfully loaded. Inspect the keypad membrane for physical damage or contamination.

    Reload the project to ensure key assignments are correctly configured. If physical key damage is present, the operator panel membrane or unit will require replacement.

    Alarm messages are not displayed on the panel

    Verify that alarms are correctly configured in the WinCC flexible project and that the associated PLC tags are mapped to the correct addresses. Check that the PLC is generating the alarm trigger bits.

    Review alarm configuration in WinCC flexible and confirm PLC tag addresses are correct. Reload the updated project to the panel and test alarm triggering from the PLC side.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart