• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1DC13-1AY0 OP 17
    Awaiting product image

    Siemens 6AV6341-1DC13-1AY0 OP 17

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1DC13-1AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1DC13-1AY0 is an OP 17 operator panel belonging to the SIMATIC HMI family of operator panels. This unit serves as a compact text-based human-machine interface designed for machine-level operation and monitoring tasks. It is part of the OP 17 series, which provides a robust and reliable solution for displaying process values, messages, and enabling operator input in industrial environments.

    The OP 17 (6AV6341-1DC13-1AY0) features a backlit LCD display capable of showing multiple lines of text and numeric values. It communicates with SIMATIC S7 PLCs via the MPI (Multi-Point Interface) protocol, and also supports the PROFIBUS DP bus system for flexible integration into existing automation networks. The panel includes a membrane keypad with function keys for direct operator interaction, and onboard memory for storing configured projects, messages, and recipes. Configuration is carried out using Siemens ProTool or WinCC flexible engineering software.

    The OP 17 is widely used in manufacturing, packaging, and process automation applications where a cost-effective, text-based operator interface is required at the machine level. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine panels. Industries such as food and beverage, automotive, and general machine building commonly deploy this panel for local operator control and diagnostics.

    Technical Specifications

    Display Type LCD, backlit
    Display Lines 4 lines of text
    Display Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 6 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC HMI OP 17

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 17 and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Timeout error on the MPI or PROFIBUS DP interface. The panel did not receive a response from the PLC within the expected time window.
    Check bus cable integrity and connector seating. Verify correct baud rate settings on both the panel and the PLC. Check for duplicate node addresses on the bus.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of the project configuration from the engineering PC to the OP 17.
    Verify the serial or MPI transfer cable is correctly connected. Ensure ProTool or WinCC flexible is configured for the correct transfer interface and baud rate. Retry the download.
    Event ID: 40000
    Configuration memory error. The panel has detected a fault or inconsistency in the stored project data.
    Re-download the project configuration to the panel using ProTool or WinCC flexible. If the error persists, perform a factory reset and re-download.
    Event ID: 50000
    Operating system error. An internal software fault has been detected in the panel firmware.
    Perform a panel restart. If the fault recurs, update the panel firmware to the latest compatible version using the appropriate Siemens tool.
    Event ID: 60000
    Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the 24 V DC supply at the panel power connector. Ensure the power supply unit is rated for the panel load and that cable runs are not causing excessive voltage drop.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms has exceeded the capacity of the alarm buffer.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in the project to reduce unnecessary alarm generation or increase the buffer size if supported.

    Frequently Asked Questions

    What PLC systems is the OP 17 (6AV6341-1DC13-1AY0) compatible with?

    The OP 17 is primarily designed for use with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S5 controllers using appropriate adapters and configuration.

    What software is used to configure the OP 17?

    The OP 17 is configured using Siemens ProTool or WinCC flexible engineering software. The project is then transferred to the panel via a serial PC/PPI cable or MPI connection.

    What is the supply voltage for the 6AV6341-1DC13-1AY0?

    The panel requires a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to prevent communication or operational faults.

    What is the front panel protection rating of the OP 17?

    The OP 17 provides IP65 protection at the front panel when correctly installed in a panel cutout with the supplied seal, making it suitable for environments with dust and water spray.

    Can the OP 17 display graphics or only text?

    The OP 17 is a text-based operator panel and does not support graphical displays. It is capable of displaying alphanumeric characters, status messages, and process values across its 4-line LCD display.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify that the supply polarity is correct and that the voltage is within the specified range.

    If the supply voltage is correct and the display remains blank, check the internal fuse if accessible. If the panel still does not power on, the internal power supply board may require replacement or the unit may need professional repair.

    Panel shows communication error and cannot connect to PLC

    Inspect the MPI or PROFIBUS DP cable for damage, loose connectors, or missing termination resistors at the bus ends. Verify the node address configured in the panel project matches the PLC address.

    Replace or reseat the bus cable connectors. Ensure termination resistors are installed only at the physical ends of the bus. Correct any address conflicts and re-download the project if configuration changes are made.

    Project download fails from engineering PC to OP 17

    Confirm that the correct transfer cable (PC/MPI adapter or serial cable) is connected and that the engineering software is set to the matching interface and baud rate. Check that the panel is in transfer mode.

    Place the panel in transfer mode via the panel menu. Verify the COM port or USB adapter driver is correctly installed on the PC. Retry the download; if it fails, try a different cable or adapter.

    Operator keys are unresponsive or intermittently responsive

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check whether the issue is consistent across all keys or limited to specific keys.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the membrane keypad assembly may need replacement. Contact a qualified repair technician to replace the keypad membrane.

    Panel repeatedly restarts or resets unexpectedly

    Monitor the 24 V DC supply voltage for instability or voltage drops under load. Check for loose power connector contacts. Review the event log on the panel for any recorded fault events prior to the restart.

    Stabilise the power supply by using a dedicated, adequately rated 24 V DC power supply unit. Secure all connector contacts. If the restarts continue with a stable supply, the panel firmware may need updating or the unit may require repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart