• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1DC14-0AY0 OP77B
    Awaiting product image

    Siemens 6AV6341-1DC14-0AY0 OP77B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1DC14-0AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1DC14-0AY0 is an OP77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is a compact, key-operated operator panel designed for machine-level visualization and control tasks in industrial automation environments. This unit provides a monochrome display with a membrane keypad interface, making it suitable for straightforward human-machine interaction without the need for a touchscreen.

    The OP77B features a 4-line text display capable of showing alphanumeric characters, supported by function keys and system keys for navigation and control. It communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible software and supports alarm management, recipe handling, and simple process value display. Its compact housing is rated IP65 on the front face, providing protection against dust and water jets in industrial environments.

    The OP77B is widely deployed in machine building, packaging machinery, conveyor systems, and general factory automation where a cost-effective, robust operator interface is required. Its compatibility with the SIMATIC S7 controller family makes it a natural fit for existing Siemens automation architectures. The panel's small footprint and panel-mount design allow integration into control cabinets and machine enclosures with minimal space requirements.

    Technical Specifications

    Display Type Monochrome STN LCD
    Display Size 4-line text display
    Display Colors Monochrome (blue/white)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 4.5 W
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Configuration Software WinCC flexible 2005 or higher
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP77B and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in WinCC flexible. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during operation.
    Inspect the communication cable for damage or loose connectors. Check bus termination at both ends of the PROFIBUS/MPI segment. Restart the panel and PLC if the connection does not recover automatically.
    Event ID: 20000
    Configuration or project download error. The project data on the panel is invalid or incompatible.
    Re-download the project from WinCC flexible to the panel. Verify that the WinCC flexible version is compatible with the OP77B firmware version.
    Event ID: 40000
    System memory low or memory overflow on the panel.
    Reduce the number of alarms, recipes, or data records stored on the device. Archive or delete unnecessary data and restart the panel.
    Event ID: 50000
    Internal device error or hardware fault detected.
    Perform a panel restart. If the error persists, check the 24 V DC supply voltage. Contact Siemens technical support or arrange for unit repair/replacement.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms exceeds the buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration in WinCC flexible to reduce the frequency or number of simultaneous alarms.
    Event ID: 70000
    Recipe data error. A recipe record could not be read or written correctly.
    Check the recipe configuration in WinCC flexible. Verify that the data types and tag assignments are correct. Re-download the project if necessary.

    Frequently Asked Questions

    Which PLCs are compatible with the OP77B (6AV6341-1DC14-0AY0)?

    The OP77B is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What software is used to configure and program the OP77B?

    The OP77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are downloaded to the panel via the MPI interface or a PC adapter cable.

    What is the supply voltage for the 6AV6341-1DC14-0AY0?

    The panel requires a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range to avoid operational issues.

    What is the front panel protection rating of the OP77B?

    The front face of the OP77B is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial machine environments.

    Does the OP77B support touchscreen input?

    No, the OP77B does not have a touchscreen. It uses a membrane keypad with function keys and system keys for operator input and navigation.

    Troubleshooting

    Panel display remains blank after power on

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify polarity is correct and voltage is within tolerance.

    Ensure the power supply is delivering stable 24 V DC. Check wiring connections at the panel terminal. If voltage is correct and display remains blank, the internal power supply or display unit may be faulty and the panel should be sent for repair.

    No communication with the PLC after installation

    Verify the MPI or PROFIBUS DP address configured in WinCC flexible matches the address set on the panel and the PLC. Check cable connections and bus termination resistors at both ends of the segment.

    Correct any address mismatches in the WinCC flexible project and re-download. Replace or reseat the communication cable. Ensure bus termination is active only at the two physical ends of the bus segment.

    Project download from WinCC flexible fails

    Check the PC-to-panel connection cable (PC adapter or MPI cable). Verify the correct COM port and transfer settings are selected in WinCC flexible. Confirm the panel is in transfer mode.

    Place the panel in transfer mode manually via the panel menu. Use a known-good PC adapter cable. Reinstall the WinCC flexible software driver if the PC does not recognise the connection.

    Alarms are not displayed on the panel

    Check the alarm configuration in WinCC flexible to confirm alarm tags are correctly linked to PLC data addresses. Verify the PLC is writing the expected values to the alarm trigger bits.

    Correct any incorrect tag assignments in the WinCC flexible project and re-download. Use the PLC monitoring tools to confirm the alarm trigger bits are being set as expected during fault conditions.

    Panel keys are unresponsive or intermittently responsive

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check if the issue is consistent across all keys or limited to specific ones.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the membrane keypad assembly may be worn or damaged and will require replacement of the front panel unit.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart