• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6341-1BA33-1AY0 OP 37
    Awaiting product image

    Siemens 6AV6341-1BA33-1AY0 OP 37

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6341-1BA33-1AY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6341-1BA33-1AY0 is an OP 37 operator panel belonging to the SIMATIC HMI OP series, designed for operator control and monitoring tasks in industrial automation environments. This unit provides a high-resolution display with integrated function keys and a full alphanumeric keyboard, enabling direct process visualization and parameter input. The OP 37 is a panel-mount operator panel developed by Siemens as part of the SIMATIC HMI product line.

    The OP 37 features a 7.5-inch STN color or monochrome display with a resolution of 640 x 480 pixels (VGA), offering clear process visualization. It communicates with PLCs via MPI, PROFIBUS-DP, and serial interfaces, making it compatible with SIMATIC S7, S5, and third-party controllers. The panel includes onboard memory for project storage, supports recipe management, alarm logging, and trend displays, and is configured using ProTool or WinCC flexible engineering software. The unit operates on 24 V DC supply voltage and is rated IP65 at the front panel for protection against dust and water ingress.

    The OP 37 is widely deployed in machine building, manufacturing automation, and process industries where robust operator interface terminals are required. It is commonly found on packaging machines, printing presses, textile machinery, and general-purpose industrial equipment. Its compatibility with the SIMATIC S7-300 and S7-400 controller families makes it a standard choice for mid-range automation systems requiring reliable local HMI functionality.

    Technical Specifications

    Display Size 7.5 inch
    Display Resolution 640 x 480 pixels (VGA)
    Display Type STN color
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 20 W
    Communication Interface MPI, PROFIBUS-DP, RS-232, RS-422/485
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP Series
    Engineering Software ProTool, WinCC flexible
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout on configured connection.
    Check MPI or PROFIBUS cable connections, verify PLC address settings, and confirm the PLC is in RUN mode. Check baud rate configuration on both HMI and PLC.
    Event ID: 10001
    Connection to PLC established after previous loss.
    Informational event. No corrective action required. Monitor for recurring disconnections which may indicate intermittent wiring faults.
    Event ID: 40000
    Project download error or project data inconsistency detected.
    Re-transfer the project from the engineering PC using ProTool or WinCC flexible. Ensure the correct PLC driver and communication parameters are configured in the project.
    Event ID: 20000
    Tag read/write error — the HMI cannot read or write a configured PLC variable.
    Verify the PLC address and data block referenced by the tag exist and are accessible. Check PLC program for correct DB or memory area definitions.
    Event ID: 50000
    Internal system error or watchdog timeout on the HMI panel.
    Perform a cold restart of the OP 37. If the error persists, reload the project firmware and application. Check the 24 V DC supply for voltage stability.
    Event ID: 60000
    Alarm buffer overflow — the number of pending alarms exceeds the configured buffer size.
    Acknowledge and clear existing alarms. Increase the alarm buffer size in the project configuration if recurring. Investigate the root cause of the high alarm frequency.
    Event ID: 70000
    Recipe data error — recipe record cannot be read from or written to memory.
    Check available memory on the OP 37. Re-download the project and recipe data. Verify recipe configuration in ProTool or WinCC flexible.

    Frequently Asked Questions

    What communication interfaces does the OP 37 (6AV6341-1BA33-1AY0) support?

    The OP 37 supports MPI, PROFIBUS-DP, RS-232, and RS-422/485 serial interfaces. This allows direct connection to SIMATIC S7-300, S7-400, S5 PLCs, and compatible third-party controllers.

    What engineering software is used to configure the OP 37?

    The OP 37 is configured using Siemens ProTool or WinCC flexible engineering software. Projects are created on a PC and transferred to the panel via a serial or MPI connection.

    What is the supply voltage for the 6AV6341-1BA33-1AY0?

    The OP 37 operates on a 24 V DC supply voltage. The power supply must be capable of providing sufficient current, typically around 1 A or more depending on backlight and peripheral load.

    What is the front panel protection rating of the OP 37?

    The front panel of the OP 37 is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel door mounting.

    Is the OP 37 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the OP 37 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS-DP. It can also communicate with S5 PLCs and certain third-party systems via serial interfaces.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the rear connector. Verify the power supply output is within tolerance. Inspect internal fuse if accessible. Confirm the backlight is not simply dimmed via contrast settings.

    Restore correct 24 V DC supply. If the supply is correct and the display remains blank, the backlight inverter or display unit may require replacement. Perform a hardware reset by cycling power.

    HMI cannot establish communication with the PLC

    Verify MPI or PROFIBUS-DP cable connections and termination resistors at both ends of the bus. Check that the HMI bus address does not conflict with other devices. Confirm baud rate settings match on both the HMI and PLC.

    Correct any address conflicts, ensure proper bus termination, and match baud rate settings. Re-download the project if communication parameters were changed. Replace the communication cable if physical damage is found.

    Touchscreen or function keys not responding

    The OP 37 uses physical function keys and a keyboard rather than a touchscreen. Check if the keyboard membrane or individual keys are mechanically damaged or contaminated. Verify the project has the correct key assignments configured.

    Clean the keyboard area and check for physical damage to the membrane keypad. If keys are unresponsive due to hardware failure, the keyboard membrane assembly may need replacement. Re-download the project to rule out configuration errors.

    Project transfer from PC fails or times out

    Check the serial or MPI cable connection between the engineering PC and the OP 37. Verify the correct COM port and transfer settings are selected in ProTool or WinCC flexible. Ensure the OP 37 is in transfer mode.

    Switch the OP 37 to transfer mode via the start screen. Use a known-good Siemens PC-PPI or PC-MPI adapter cable. Confirm the correct baud rate and port settings in the engineering software and retry the transfer.

    Alarms are displayed but cannot be acknowledged

    Check the project configuration to confirm acknowledgment is enabled for the relevant alarm class. Verify the PLC bit or tag linked to alarm acknowledgment is writable by the HMI. Check operator access level permissions in the project.

    Correct the alarm class acknowledgment settings in ProTool or WinCC flexible and re-download the project. Ensure the PLC data area used for acknowledgment bits is not write-protected. Adjust user access levels if operator permissions are restricting acknowledgment.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart