• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC01-7AB0 SIMATIC OP 35
    Awaiting product image

    Siemens 6AV4530-1BC01-7AB0 SIMATIC OP 35

    € 1.995,00

    Reset
    Clear
    SKU: 6AV4530-1BC01-7AB0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC01-7AB0 is an Operator Panel (OP 35) belonging to the SIMATIC HMI family, designed for industrial human-machine interface applications. This unit provides a monochrome graphical display with integrated function keys for process visualization and operator control. It is part of Siemens' established SIMATIC OP series, which was widely deployed across automation environments requiring reliable panel-based interaction with PLC systems.

    The OP 35 features a built-in STN LCD display with a resolution of 320 x 240 pixels and supports a range of communication interfaces including MPI (Multi-Point Interface) and PROFIBUS-DP, enabling direct integration with SIMATIC S7-300 and S7-400 controllers. The panel includes configurable function keys, numeric and alphanumeric input capability, and supports configuration via SIMATIC ProTool software. It operates on a 24 V DC supply and is built to withstand the demands of industrial environments with an IP65 front panel protection rating.

    The SIMATIC OP 35 is commonly used in manufacturing, process automation, and machine tool industries where operators require a compact, robust interface for monitoring process values, entering setpoints, and acknowledging alarms. Its compatibility with the SIMATIC S7 controller family makes it well-suited for integration into existing Siemens automation architectures. The panel is particularly prevalent in applications such as conveyor systems, packaging machinery, and general-purpose industrial equipment.

    Technical Specifications

    Display Type STN LCD, Monochrome
    Display Resolution 320 x 240 pixels (QVGA)
    Display Size 5.7 inch
    Input Voltage 24 V DC
    Power Consumption Approx. 15 W
    Communication Interface MPI, PROFIBUS-DP
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    Configuration Software SIMATIC ProTool
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between OP 35 and connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify the configured station address matches the PLC settings. Restart both the panel and PLC if necessary.
    Event ID: 10001
    Timeout error on the MPI or PROFIBUS-DP bus. The controller did not respond within the expected time window.
    Check bus cable integrity and connector seating. Verify baud rate settings on both the panel and PLC. Ensure no address conflicts exist on the bus.
    Event ID: 20000
    Configuration download error. The project data could not be successfully transferred to the OP 35.
    Verify the ProTool project is compiled without errors. Check the serial or MPI transfer cable connection. Ensure the panel is in transfer mode before initiating the download.
    Event ID: 40000
    Internal memory error detected. The panel has identified a fault in its internal data or program memory.
    Perform a factory reset and re-download the project configuration. If the error persists, the internal memory may be corrupted and the unit should be repaired or replaced.
    Event ID: 50000
    Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the supply voltage at the panel power connector. Ensure the power supply unit is rated adequately for the load. Check for loose or corroded wiring connections.
    Event ID: 60000
    Tag update error. One or more configured tags cannot be read from or written to the connected PLC.
    Verify the PLC data block addresses referenced in the ProTool project match the actual PLC program. Check that the PLC is in RUN mode and the relevant data blocks exist.
    Event ID: 70000
    Operating system startup error. The panel failed to complete its boot sequence correctly.
    Cycle power to the panel. If the error recurs, attempt a firmware re-flash or factory reset. If unsuccessful, the unit likely requires hardware-level repair.

    Frequently Asked Questions

    Which PLC families are compatible with the SIMATIC OP 35?

    The OP 35 is compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS-DP interfaces. It can also communicate with SIMATIC S5 controllers using appropriate protocol adapters.

    What software is required to configure the OP 35?

    The OP 35 is configured using Siemens SIMATIC ProTool software. Projects are created on a PC and downloaded to the panel via a serial PC/PPI cable or MPI connection.

    What is the supply voltage for the 6AV4530-1BC01-7AB0?

    The panel requires a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range to prevent undervoltage faults.

    What is the front panel protection rating of the OP 35?

    The front panel of the OP 35 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for most industrial panel installations.

    Can the OP 35 display graphical elements and trend curves?

    Yes, the OP 35 supports graphical display elements including bar graphs and trend curves, in addition to text-based process value displays and alarm messages, within the limits of its 320 x 240 pixel monochrome display.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power terminals using a multimeter. Inspect the internal fuse if accessible. Verify the power supply unit is functioning correctly.

    Restore the supply voltage to within the 24 V DC specification. Replace any blown internal fuse with the correct rating. If the display backlight has failed, the backlight unit or the entire display assembly may require replacement.

    Panel displays 'No connection to PLC' or communication error on startup

    Inspect the MPI or PROFIBUS-DP cable for physical damage, loose connectors, or missing bus termination resistors at both ends of the bus segment. Verify the station address configured in ProTool matches the PLC address.

    Replace or reseat the communication cable. Install correct bus termination resistors at both ends of the MPI or PROFIBUS-DP segment. Correct the station address in the ProTool project and re-download the configuration.

    Project download fails or transfer cannot be initiated

    Confirm the panel is set to transfer mode before starting the download from ProTool. Check the PC-to-panel cable (serial or MPI adapter) and the COM port settings on the PC.

    Set the panel to transfer mode via the panel's startup menu. Verify the correct COM port and transfer speed are selected in ProTool. Replace the transfer cable if communication cannot be established.

    Function keys do not respond or produce incorrect actions

    Check the ProTool project configuration to confirm function key assignments are correctly defined. Test individual keys to determine if the fault is isolated to specific keys or affects all keys.

    Re-download the ProTool project to ensure the latest configuration is loaded. If specific keys are physically unresponsive, the keypad membrane or internal PCB contact may be worn and require replacement.

    Panel reboots repeatedly or fails to complete startup

    Monitor the supply voltage during startup for voltage drops caused by an undersized power supply. Check for corrupted project data by attempting a factory reset and observing whether the panel boots to the default screen.

    Upgrade the power supply to one with sufficient current capacity. Perform a factory reset and re-download the ProTool project. If the panel continues to reboot, the unit likely has a hardware fault requiring professional repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart