• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC01-7AA0 SIMATIC OP 30
    Awaiting product image

    Siemens 6AV4530-1BC01-7AA0 SIMATIC OP 30

    € 1.995,00

    Reset
    Clear
    SKU: 6AV4530-1BC01-7AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC01-7AA0 is an OP 30 operator panel belonging to the SIMATIC HMI family, designed for machine-level operator control and monitoring in industrial automation environments. This unit provides a text-based interface for process visualization, parameter input, and status display, and is part of Siemens' established range of operator panels intended for direct integration with SIMATIC PLCs. The OP 30 was developed to offer a robust and reliable human-machine interface solution for applications where a compact, character-based display is sufficient.

    The OP 30 features a multi-line LCD text display capable of showing alphanumeric characters, allowing operators to read process values, alarms, and messages. It communicates with SIMATIC S5 and S7 PLCs via the MPI or PROFIBUS-DP interface, enabling direct data exchange without additional gateways. The panel includes a membrane keypad with function keys for navigation and control input, and supports configuration via the SIMATIC ProTool software package. The unit operates on a 24 V DC supply and is designed to meet industrial environmental requirements including resistance to vibration and electrical noise.

    The OP 30 is typically deployed on machine control panels in manufacturing, process, and packaging industries where operators need to interact with PLC-controlled machinery. Its compact form factor and front-panel IP65 protection rating make it suitable for flush mounting in control cabinet doors. The panel is commonly found on machine tools, conveyor systems, and general-purpose industrial machinery where text-based status readout and parameter entry are the primary HMI requirements.

    Technical Specifications

    Display Type LCD text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS-DP
    Keypad Type Membrane keypad with function keys
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +70 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel flush mounting
    Series/Product Family SIMATIC OP 30
    Configuration Software SIMATIC ProTool

    Common Error Codes & System Events

    Event ID: 10000
    No connection to PLC. The operator panel cannot establish communication with the configured PLC.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify PLC address settings match the OP 30 configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout. The connection to the PLC was interrupted during operation.
    Inspect cable integrity and connector seating. Check for network address conflicts on the MPI/PROFIBUS segment. Restart the OP 30 and PLC if the fault persists.
    Event ID: 20000
    Configuration error. The project loaded on the OP 30 is incompatible or corrupted.
    Re-transfer the project from SIMATIC ProTool to the OP 30. Verify that the correct device type and firmware version are selected in the project settings.
    Event ID: 40000
    Operating system error. An internal system fault has been detected.
    Perform a power cycle on the OP 30. If the error recurs, perform a factory reset and re-download the project configuration.
    Event ID: 50000
    Memory error. Insufficient memory available to load or run the configured project.
    Reduce the project size by removing unused screens or messages. Verify that the project does not exceed the memory capacity of the OP 30.
    Event ID: 60000
    Alarm buffer overflow. The number of pending alarms exceeds the alarm buffer capacity.
    Acknowledge and clear existing alarms. Review the alarm configuration in ProTool to reduce the number of simultaneously active alarms.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 30 (6AV4530-1BC01-7AA0)?

    The OP 30 is compatible with SIMATIC S7-300, S7-400, and S5 PLCs via MPI or PROFIBUS-DP communication interfaces. Correct addressing and network configuration must be set in the ProTool project.

    What software is used to configure the OP 30?

    The OP 30 is configured using SIMATIC ProTool, Siemens' legacy HMI configuration software. Projects are transferred to the panel via the MPI interface or a serial download cable.

    What is the supply voltage for the OP 30?

    The OP 30 operates on a 24 V DC supply voltage, which is the standard control voltage used in SIMATIC automation systems.

    What is the front panel protection rating of the OP 30?

    The front panel of the OP 30 carries an IP65 protection rating, making it suitable for flush mounting in control cabinet doors where dust and water spray may be present.

    Can the OP 30 display graphical content?

    No, the OP 30 is a text-based operator panel and supports only alphanumeric character display. It does not support bitmap graphics or process graphics screens.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals of the OP 30. Measure voltage at the connector and inspect the supply wiring for breaks or loose connections.

    Restore the 24 V DC supply if absent. If voltage is present but display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair or replacement.

    OP 30 shows 'No connection to PLC' message continuously

    Verify the MPI or PROFIBUS-DP cable is correctly connected and terminated at both ends. Check that the PLC station address configured in ProTool matches the actual PLC address setting.

    Correct any address mismatches in the ProTool project and re-download. Replace the communication cable if damaged. Ensure termination resistors are active only at the two physical ends of the bus segment.

    Project transfer from ProTool fails or does not complete

    Check the download cable connection between the PC and the OP 30 MPI port. Verify that the correct COM port and transfer speed are selected in ProTool. Confirm the OP 30 is in transfer mode.

    Switch the OP 30 to transfer mode via the system menu. Use a known-good PC-to-MPI adapter cable. Reduce the transfer baud rate in ProTool if communication errors occur during download.

    Function keys do not respond to presses

    Inspect the membrane keypad for physical damage, contamination, or deformation. Test each key systematically using the OP 30 built-in key test function if available in the system menu.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly must be replaced. Contact a qualified repair technician for internal keypad replacement.

    Alarm messages are displayed in incorrect language or with garbled characters

    Check the language and character set settings in the ProTool project configuration. Verify that the correct code page is selected for the target language.

    Correct the language and character set settings in the ProTool project and re-transfer the project to the OP 30. Ensure the firmware version on the panel supports the required character set.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart