• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC01-5HA0 SIMATIC OP 35
    Awaiting product image

    Siemens 6AV4530-1BC01-5HA0 SIMATIC OP 35

    € 1.995,00

    Reset
    Clear
    SKU: 6AV4530-1BC01-5HA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC01-5HA0 is an Operator Panel (OP 35) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a robust operator interface for monitoring and controlling machine processes, and is part of Siemens' established SIMATIC OP series of operator panels. The OP 35 is configured for use with Siemens SIMATIC S5 and S7 PLC families, enabling direct integration into existing Siemens automation architectures.

    The OP 35 features a monochrome LCD display with a resolution suitable for displaying process values, alarm messages, and operator prompts. It includes a membrane keypad for operator input, providing dedicated function keys and numeric entry capability. Communication is facilitated via an MPI (Multi-Point Interface) or serial interface, allowing connection to SIMATIC PLCs. The panel supports configurable display pages, alarm logging, and recipe management functions, and is designed for panel-mount installation with a defined front-panel cutout.

    The SIMATIC OP 35 is widely used in machine building, manufacturing automation, and process control applications where a compact and reliable operator interface is required. It is suitable for industries such as automotive, food and beverage, packaging, and general factory automation. Its compatibility with the SIMATIC S7 and S5 controller families makes it a practical choice for both new installations and retrofitting existing Siemens-based control systems.

    Technical Specifications

    Display Type Monochrome LCD
    Input Voltage 24 V DC
    Communication Interface MPI, Serial (RS-232/RS-422)
    Mounting Panel mount
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Protection Rating (Front) IP 65
    Protection Rating (Rear) IP 20
    Series/Product Family SIMATIC OP 35
    PLC Compatibility SIMATIC S5, SIMATIC S7
    Certifications CE, UL

    Common Error Codes & System Events

    System Error 1
    Configuration data missing or corrupted in the operator panel memory.
    Reload the project configuration using ProTool or STEP 7 software. Perform a memory reset if necessary and re-download the project.
    System Error 2
    Communication error between the OP 35 and the connected PLC.
    Check MPI or serial cable connections and termination resistors. Verify PLC address settings match the OP 35 configuration. Ensure the PLC is in RUN mode.
    System Error 3
    Overflow of the alarm buffer; too many alarms generated in a short period.
    Acknowledge and clear pending alarms. Review the alarm configuration in ProTool to reduce alarm frequency or increase buffer size.
    System Error 4
    Recipe data error; recipe record cannot be read or written.
    Check recipe configuration in the project. Verify that the PLC data blocks referenced by the recipe are correctly defined and accessible.
    System Error 5
    Internal watchdog timeout; the panel processor did not respond within the expected time.
    Perform a power cycle on the OP 35. If the fault persists, reload the project configuration. Check for hardware faults and consider unit replacement if the issue recurs.
    System Error 6
    Display backlight failure or display hardware fault detected.
    Check the backlight power supply connections internally. Replace the backlight unit or the display module if the screen remains blank or dim after power cycling.
    System Error 7
    Keypad input fault; one or more keys are not responding or are stuck.
    Inspect the membrane keypad for physical damage or contamination. Clean the keypad surface. If keys remain unresponsive, replace the membrane keypad assembly.
    System Error 8
    Power supply voltage out of range; the 24 V DC supply is outside acceptable limits.
    Measure the supply voltage at the panel power connector. Ensure the supply is within the 24 V DC nominal range. Check wiring and the external power supply unit.

    Frequently Asked Questions

    What PLC families are compatible with the SIMATIC OP 35?

    The OP 35 is compatible with Siemens SIMATIC S5 and S7 PLC families, communicating via MPI or serial interfaces depending on the configuration.

    What software is used to configure the OP 35?

    The OP 35 is configured using Siemens ProTool configuration software, which allows creation and download of operator panel projects.

    What is the supply voltage for the 6AV4530-1BC01-5HA0?

    The OP 35 operates on a 24 V DC supply voltage.

    What is the front panel protection rating of the OP 35?

    The front panel of the OP 35 carries an IP 65 protection rating, making it suitable for environments where dust and water spray may be present.

    Can the OP 35 be used as a replacement in an existing SIMATIC S5 installation?

    Yes, the OP 35 supports communication with SIMATIC S5 PLCs via serial interface, making it suitable for use in existing S5-based control systems.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check internal fuses and the backlight circuit.

    Ensure the supply voltage is within specification. Replace the internal fuse if blown. If the backlight is faulty, replace the backlight unit or the display module.

    OP 35 cannot communicate with the SIMATIC PLC

    Verify MPI or serial cable integrity and connector seating. Check that the MPI address and baud rate configured in the OP 35 project match the PLC settings.

    Replace or reseat the communication cable. Correct address and baud rate settings in ProTool and re-download the project. Ensure MPI bus termination is correctly applied at both ends of the network.

    Operator panel displays configuration error or missing project message

    The panel memory may be empty or the project data may be corrupted, typically after a battery failure or memory fault.

    Reconnect the OP 35 to the programming PC and re-download the project using ProTool. Perform a memory reset on the panel before downloading if errors persist.

    Keypad keys are unresponsive or intermittently failing

    Inspect the membrane keypad for physical damage, contamination, or wear. Test individual keys to identify which are affected.

    Clean the keypad surface with a dry cloth. If keys remain non-functional, replace the membrane keypad assembly with a compatible spare part.

    Alarm messages are not displayed or alarms are lost

    Check the alarm buffer configuration in ProTool. Verify that the PLC bits linked to alarm triggers are correctly mapped and that the PLC program is setting them as expected.

    Increase the alarm buffer size in the project configuration. Verify PLC data block addresses referenced by alarms. Re-download the updated project to the OP 35.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart