• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC01-5HA SIMATIC OP 5
    Awaiting product image

    Siemens 6AV4530-1BC01-5HA SIMATIC OP 5

    € 1.995,00

    Reset
    Clear
    SKU: 6AV4530-1BC01-5HA Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC01-5HA is an Operator Panel (OP 5) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This compact operator panel provides a text-based display interface for monitoring and controlling machine processes. It is part of Siemens' established SIMATIC HMI portfolio, offering reliable operator interaction for straightforward control tasks.

    The OP 5 features a single-line LCD text display capable of showing alphanumeric characters, enabling operators to read process values, status messages, and alarms. It is equipped with a membrane keypad for direct operator input, including function keys that can be assigned to specific control tasks. The unit communicates via the MPI (Multi-Point Interface) protocol, allowing direct integration with Siemens SIMATIC S5 and S7 PLCs. Configuration is performed using the ProTool software package, and the panel operates on a 24 V DC supply voltage.

    The SIMATIC OP 5 is typically deployed in machine-level control applications where a compact, cost-effective operator interface is required without the need for graphical display capabilities. It is commonly found in manufacturing machinery, conveyor systems, packaging equipment, and process automation installations. Its small form factor and straightforward functionality make it suitable for panel-mounting in confined control cabinet spaces where basic operator interaction is sufficient.

    Technical Specifications

    Series/Product Family SIMATIC HMI OP 5
    Display Type LCD text display
    Display Lines 1 line
    Input/Operating Voltage 24 V DC
    Communication Interface MPI (Multi-Point Interface)
    PLC Compatibility SIMATIC S5, SIMATIC S7
    Configuration Software ProTool
    Mounting Panel mounting
    Operating Temperature 0 °C to 50 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Protection Rating (Front) IP 65
    Protection Rating (Rear) IP 00
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP 5 and the connected PLC. The panel cannot establish or maintain a connection via MPI.
    Check MPI cable connections and termination resistors. Verify MPI address settings on both the OP 5 and the PLC. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Timeout error during communication with the PLC. The OP 5 did not receive a response within the expected time frame.
    Check MPI bus cable integrity and connector seating. Verify bus termination at both ends of the MPI network. Reduce MPI bus load if multiple devices are connected.
    Event ID: 20000
    Configuration error detected. The project loaded on the OP 5 is incompatible or corrupted.
    Re-transfer the project from ProTool to the OP 5. Verify that the ProTool project version is compatible with the OP 5 firmware version.
    Event ID: 20001
    Memory error on the operator panel. Internal memory content may be corrupted or incomplete.
    Perform a complete reset of the OP 5 and re-download the project using ProTool. If the error persists, the internal memory module may require replacement.
    Event ID: 30000
    Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the supply voltage at the OP 5 power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
    Event ID: 40000
    Keypad fault detected. One or more keys on the membrane keypad are not responding or are registering continuous activation.
    Inspect the membrane keypad for physical damage or contamination. Clean the keypad surface. If the fault persists, the keypad membrane assembly may need replacement.

    Frequently Asked Questions

    What communication interface does the OP 5 use to connect to a PLC?

    The SIMATIC OP 5 communicates via the MPI (Multi-Point Interface) protocol, which allows direct connection to Siemens SIMATIC S5 and S7 series PLCs.

    What software is required to configure and program the OP 5?

    The OP 5 is configured using Siemens ProTool software. Projects are created in ProTool and then transferred to the panel via the MPI interface or a serial download cable.

    What is the supply voltage for the 6AV4530-1BC01-5HA?

    The OP 5 operates on a 24 V DC supply voltage, which is the standard supply voltage for SIMATIC HMI operator panels of this generation.

    What is the front panel protection rating of the OP 5?

    The front panel of the OP 5 carries an IP 65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can the OP 5 display graphical content or images?

    No, the OP 5 is a text-based operator panel with a single-line alphanumeric LCD display. It does not support graphical content or bitmap images.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the unit. Check internal fuse if accessible. Verify that the power supply unit is functioning correctly.

    Ensure the supply voltage is stable and within the 24 V DC operating range. Replace any blown internal fuse with the correct rating. If the display backlight has failed, the display assembly may require replacement.

    OP 5 fails to communicate with the connected SIMATIC PLC

    Check the MPI cable for continuity and correct pin assignment. Verify the MPI address configured on the OP 5 matches the project settings and does not conflict with other devices on the bus. Confirm bus termination is applied at both ends of the MPI network.

    Replace the MPI cable if damaged. Correct the MPI address settings via the OP 5 configuration menu. Ensure only the two end devices on the MPI bus have termination resistors enabled.

    Project transfer from ProTool fails or is interrupted

    Check the serial or MPI download cable connection between the programming device and the OP 5. Verify that the correct COM port and transfer settings are selected in ProTool. Confirm the OP 5 is in transfer mode.

    Replace the download cable if faulty. Set the OP 5 to transfer mode by navigating to the system menu. Ensure ProTool project settings match the OP 5 hardware version and firmware.

    Keypad buttons are unresponsive or register incorrect inputs

    Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test each key individually to identify whether the fault is isolated to specific keys or affects the entire keypad.

    Clean the keypad surface with a dry cloth to remove contamination. If individual keys are damaged or the membrane is torn, replace the keypad membrane assembly. Ensure no mechanical obstruction is pressing against the keypad.

    OP 5 displays a communication timeout message repeatedly during operation

    Monitor the MPI bus for excessive traffic or address conflicts. Check that all devices on the MPI network have unique addresses. Verify the PLC program scan time is within acceptable limits for MPI communication response.

    Resolve any MPI address conflicts by reassigning unique addresses to each device. Reduce the number of devices on the MPI bus if bus loading is excessive. Adjust the communication timeout parameter in the ProTool project if the PLC response time is inherently slow.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart