• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV4530-1BC01-7HA0 SIMATIC OP 17
    Awaiting product image

    Siemens 6AV4530-1BC01-7HA0 SIMATIC OP 17

    € 628,00

    Reset
    Clear
    SKU: 6AV4530-1BC01-7HA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV4530-1BC01-7HA0 is an Operator Panel (OP 17) belonging to the SIMATIC HMI family, designed for operator control and monitoring tasks in industrial automation environments. This unit provides a text-based display interface for machine-level operation and is part of Siemens' established range of compact operator panels. It is intended for use with SIMATIC S5 and S7 programmable logic controllers via serial communication links.

    The OP 17 features a backlit LCD display capable of showing multiple lines of text and numeric values, enabling operators to monitor process variables and enter setpoints directly at the machine. It supports the PROFIBUS-DP and MPI communication protocols, allowing integration into existing Siemens automation networks. The panel includes function keys and numeric input keys for direct operator interaction, and configuration is performed using the ProTool software package. The unit operates on a 24 V DC supply and is designed for panel-mount installation with a defined front-face protection rating.

    The SIMATIC OP 17 is widely used in manufacturing, process automation, and machine tool applications where a compact, cost-effective operator interface is required. It is suited for environments where text-based status display and parameter entry are sufficient, such as conveyor systems, packaging machinery, and general-purpose industrial machines. Its compatibility with the SIMATIC S5 and S7 controller families makes it a practical choice for both new installations and retrofit projects on legacy Siemens-controlled equipment.

    Technical Specifications

    Display Type Backlit LCD
    Display Lines 4 lines of text
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface PROFIBUS-DP, MPI, RS 232, RS 422/485
    PLC Compatibility SIMATIC S5, SIMATIC S7
    Configuration Software ProTool
    Mounting Panel mount (flush mounting)
    IP Rating (Front) IP 65
    IP Rating (Rear) IP 20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Certifications CE, UL

    Common Error Codes & System Events

    System Error 1
    Communication error between OP 17 and connected PLC; connection to the controller has been lost or cannot be established.
    Check the communication cable connections and verify the correct communication parameters (baud rate, station address) are configured in ProTool and on the PLC.
    System Error 2
    Configuration data on the OP 17 is invalid or corrupted; the panel cannot load the project correctly.
    Re-download the project configuration from ProTool to the OP 17. If the error persists, perform a memory reset and re-transfer the project.
    System Error 6
    Overflow of the alarm buffer; more alarms have been generated than the buffer can store.
    Acknowledge and clear pending alarms on the panel. Review the alarm configuration in ProTool to reduce unnecessary alarm generation.
    System Error 10
    Incorrect or incompatible firmware version detected on the OP 17 relative to the ProTool project version.
    Update the OP 17 firmware to the version compatible with the ProTool project, or regenerate the project using the matching ProTool version.
    System Error 14
    Tag or variable address referenced in the project cannot be found or accessed on the connected PLC.
    Verify that all PLC variable addresses defined in the ProTool project exist and are accessible in the PLC program. Correct any address mismatches.
    System Error 20
    Internal memory error on the OP 17; flash memory or RAM fault detected during self-test.
    Perform a complete memory reset of the panel. If the error recurs after re-downloading the project, the unit may require hardware repair or replacement.
    System Error 40
    Power supply voltage is outside the permissible operating range; undervoltage or overvoltage condition detected.
    Measure the 24 V DC supply voltage at the panel terminals. Ensure the supply is stable and within the specified tolerance range of 20.4 V DC to 28.8 V DC.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP 17 (6AV4530-1BC01-7HA0)?

    The OP 17 is compatible with SIMATIC S5 and SIMATIC S7 PLCs. Communication is established via MPI, PROFIBUS-DP, RS 232, or RS 422/485 serial interfaces depending on the connected controller type.

    What software is required to configure the OP 17?

    The OP 17 is configured using Siemens ProTool software. The project is created on a PC and then downloaded to the panel via a serial programming cable.

    What is the supply voltage for the OP 17?

    The OP 17 operates on a 24 V DC supply. The permissible voltage range is typically 20.4 V DC to 28.8 V DC to account for supply tolerances.

    What is the front-face protection rating of the OP 17?

    The front face of the OP 17 carries an IP 65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for panel-mount installation in industrial environments.

    Can the OP 17 be used as a replacement for older SIMATIC operator panels?

    Yes, the OP 17 is commonly used as a replacement or upgrade for older SIMATIC OP panels in retrofit projects, provided the communication interface and ProTool project configuration are adapted accordingly.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power terminals using a multimeter. Verify the supply is within the 20.4 V DC to 28.8 V DC range. Inspect the internal fuse if accessible.

    Restore the supply voltage to within specification. Replace any blown internal fuse with the correct rating. If the display backlight has failed, the panel may require backlight or display module replacement.

    OP 17 displays a persistent communication error and cannot connect to the PLC

    Verify the communication cable is correctly wired and securely connected at both the OP 17 and PLC ends. Check that the baud rate, station address, and protocol settings in the ProTool project match the PLC configuration.

    Correct any wiring faults or loose connectors. Align the communication parameters in ProTool with those configured on the PLC. Re-download the project to the OP 17 after making corrections.

    Project download from ProTool to the OP 17 fails or is interrupted

    Check the serial programming cable connection between the PC and the OP 17. Verify that the correct COM port and transfer settings are selected in ProTool. Confirm the ProTool version is compatible with the panel firmware version.

    Replace the programming cable if faulty. Select the correct COM port in ProTool transfer settings. Update the panel firmware or the ProTool project to ensure version compatibility before retrying the download.

    Function keys on the OP 17 do not respond or produce incorrect actions

    Check the ProTool project configuration to confirm that the function keys are correctly assigned to the intended actions. Test each key individually to identify whether the fault is with a specific key or all keys.

    Re-download the corrected ProTool project if key assignments are incorrect. If a specific key is physically unresponsive, the keypad membrane may be worn or damaged and will require replacement.

    Alarm messages are not displayed or alarms are not acknowledged correctly

    Review the alarm configuration in the ProTool project to verify that alarm tags are correctly linked to PLC addresses. Check that the PLC program is correctly setting and resetting the alarm bits.

    Correct any tag address mismatches in the ProTool project and re-download to the panel. Ensure the PLC program logic correctly controls the alarm bits. Clear the alarm buffer if it has overflowed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart