• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6ES7626-2AG00-0AE3 SIMATIC C7-626
    Siemens 6ES7626-2AG00-0AE3 SIMATIC C7-626

    Siemens 6ES7626-2AG00-0AE3 SIMATIC C7-626

    € 1.668,00

    Reset
    Clear
    SKU: 6ES7626-2AG00-0AE3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens SIMATIC C7-626, part number 6ES7626-2AG00-0AE3, is a compact combined controller and operator panel unit belonging to the SIMATIC C7 product family. It integrates an S7-300 compatible CPU with an operator panel in a single housing, eliminating the need for a separate PLC and HMI device. This all-in-one design is intended for machine-level automation where panel space and wiring complexity must be minimized.

    The C7-626 features a built-in STN monochrome display with touch or key-based operator input, and integrates a CPU with onboard I/O, MPI communication interface, and PROFIBUS-DP connectivity for distributed I/O expansion. The unit supports programming via STEP 7 for the PLC logic and ProTool or WinCC flexible for the HMI configuration, allowing both environments to be managed from a single engineering framework. Onboard memory supports user programs and data retention, with the option to use a Micro Memory Card (MMC) for program backup and transfer. The device is designed for 24 V DC supply and is built to industrial standards for reliability in demanding environments.

    The SIMATIC C7-626 is widely used in machine automation applications such as packaging machinery, conveyor systems, printing machines, and textile equipment where a compact footprint is essential. Its integrated design reduces installation time and cabinet space requirements, making it suitable for OEM machine builders. The combination of PLC functionality and operator interface in one unit simplifies maintenance and reduces the number of components that need to be managed on the machine.

    Technical Specifications

    Series/Product Family SIMATIC C7
    Display Type STN monochrome LCD
    Operator Input Membrane keys and function keys
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS-DP
    Programming Software (PLC) STEP 7
    Programming Software (HMI) ProTool / WinCC flexible
    Onboard Digital Inputs 16
    Onboard Digital Outputs 16
    Memory Card Support Micro Memory Card (MMC)
    Operating Temperature 0 °C to +55 °C
    Storage Temperature -20 °C to +70 °C
    Relative Humidity 10 % to 95 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 16# 4500
    CPU in STOP mode due to programming error or user-initiated stop
    Check the STEP 7 diagnostic buffer for the cause of the STOP. Correct the program error and perform a warm restart or power cycle.
    Event ID: 16# 4520
    Cycle time exceeded — watchdog timeout triggered
    Optimize the user program to reduce scan cycle time. Check for infinite loops or excessive communication load in the program.
    Event ID: 16# 2521
    I/O access error — peripheral input/output module not responding
    Check wiring and connections to the I/O module. Verify module is correctly seated and powered. Replace faulty module if necessary.
    Event ID: 16# 3501
    Memory card error — Micro Memory Card not recognized or read failure
    Reseat the Micro Memory Card. Replace the card if the error persists. Ensure the correct card type is used.
    Event ID: 16# 4930
    Battery voltage low or battery failure (RAM backup)
    Replace the backup battery. Perform a memory reset and reload the user program after battery replacement.
    PROFIBUS DP Bus Fault
    Loss of communication on the PROFIBUS-DP network, one or more DP slaves not responding
    Check PROFIBUS cable connections, termination resistors at both ends of the bus, and slave station addresses. Verify slave devices are powered and operational.
    MPI Communication Error
    MPI interface communication failure with programming device or HMI
    Check MPI cable and connector integrity. Verify correct MPI address and baud rate settings on all connected devices.

    Frequently Asked Questions

    What programming software is required for the SIMATIC C7-626?

    The PLC portion is programmed using Siemens STEP 7, while the HMI screens are configured using ProTool or WinCC flexible. Both tools run on a standard engineering PC connected via MPI or PROFIBUS.

    What communication interfaces are available on the C7-626?

    The C7-626 provides an MPI interface for programming and HMI communication, and a PROFIBUS-DP interface for connecting distributed I/O slaves and other PROFIBUS devices.

    Does the C7-626 support Micro Memory Cards for program storage?

    Yes, the C7-626 supports Siemens Micro Memory Cards (MMC) for program storage, backup, and transfer. The MMC retains the program without a battery.

    What is the supply voltage for the SIMATIC C7-626?

    The C7-626 operates on a 24 V DC supply voltage, which is standard for SIMATIC C7 series devices.

    Is the C7-626 compatible with S7-300 expansion modules?

    The C7-626 integrates an S7-300 compatible CPU and can be expanded using standard S7-300 signal modules connected via the backplane bus or PROFIBUS-DP for distributed I/O.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply is present at the power terminals. Measure voltage at the input connector and verify the power supply unit output is within tolerance.

    Restore correct 24 V DC supply. If supply is confirmed correct, inspect internal fuse and replace if blown. If the display hardware is faulty, the unit may require repair or replacement of the display assembly.

    CPU remains in STOP mode after power on

    Connect a programming device via MPI and open the STEP 7 diagnostic buffer to read the last stop event. Check for program errors, I/O access faults, or memory card issues.

    Correct any identified program errors in STEP 7. If the Micro Memory Card is corrupted, replace it and reload the program. Perform a CPU memory reset (MRES) if necessary before reloading.

    PROFIBUS-DP slaves not communicating

    Check the PROFIBUS network cable for continuity and correct termination at both ends of the bus. Verify all slave station addresses are unique and match the hardware configuration in STEP 7.

    Repair or replace damaged PROFIBUS cables. Ensure termination resistors are active only at the two physical ends of the bus. Download the corrected hardware configuration to the CPU.

    HMI screens not updating or operator input not responding

    Check MPI or PROFIBUS connection between the C7 HMI and the CPU. Verify the ProTool or WinCC flexible project is correctly compiled and downloaded to the device.

    Re-download the HMI project to the C7 unit. If communication errors persist, check MPI address conflicts and cable integrity. Restart the device after a successful download.

    Micro Memory Card not recognized

    Power down the unit and reseat the Micro Memory Card. Inspect the card slot contacts for contamination or damage. Verify the card is a Siemens-approved MMC for the C7 series.

    Clean the card contacts and reseat firmly. Replace the MMC with a new Siemens Micro Memory Card if the error persists. Reload the user program after card replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart