• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6ES7624-1DE01-0AE3 SIMATIC C7-624
    Awaiting product image

    Siemens 6ES7624-1DE01-0AE3 SIMATIC C7-624

    € 917,00

    Reset
    Clear
    SKU: 6ES7624-1DE01-0AE3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens SIMATIC C7-624, part number 6ES7624-1DE01-0AE3, is a compact combined controller and operator panel unit belonging to the SIMATIC C7 product family. It integrates a programmable logic controller (PLC) based on the S7-300 CPU architecture with an operator panel (OP) into a single housing, eliminating the need for separate HMI and controller hardware. This all-in-one design is intended for machine-level automation where space and wiring economy are priorities.

    The C7-624 features an integrated monochrome display with touch or membrane key operation and supports MPI (Multi-Point Interface) communication for connection to SIMATIC S7 networks and programming devices. It includes onboard digital I/O points, integrated CPU functionality compatible with STEP 7 programming software, and supports ProTool for HMI configuration. The unit operates on 24 V DC supply voltage and is built to industrial standards for reliability in demanding environments, with a compact panel-mount form factor.

    The SIMATIC C7-624 is typically deployed in standalone machine control applications such as packaging machinery, conveyor systems, and small-scale process automation where a combined HMI and controller reduces cabinet space and installation complexity. Its S7-300-compatible CPU makes it suitable for applications requiring structured ladder logic or function block programming, and its integrated operator interface allows direct machine interaction without additional HMI hardware.

    Technical Specifications

    Input Voltage 24 V DC
    Display Type Monochrome LCD
    Communication Interface MPI (Multi-Point Interface)
    Onboard Digital Inputs 16
    Onboard Digital Outputs 16
    CPU Compatibility S7-300 compatible
    Programming Software SIMATIC STEP 7
    HMI Configuration Software ProTool
    Mounting Panel mounting
    Operating Temperature 0 °C to +55 °C
    Storage Temperature -20 °C to +70 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    IP Protection Rating IP65 (front panel)
    Series/Product Family SIMATIC C7

    Common Error Codes & System Events

    Event ID: 16# 0000
    No error present; system operating normally.
    No action required. Monitor system for recurring events.
    STOP mode
    CPU has entered STOP mode due to a programming error, hardware fault, or manual switch operation.
    Check the diagnostic buffer in STEP 7 (SIMATIC Manager > Module Information > Diagnostic Buffer) to identify the cause. Correct the fault and perform a warm or cold restart.
    SF LED (System Fault)
    The red SF LED is illuminated, indicating a system or programming fault has been detected by the CPU.
    Connect a programming device and read the diagnostic buffer via STEP 7 to identify the specific fault. Correct configuration or hardware issues as indicated.
    BF LED (Bus Fault)
    The red BF LED is illuminated, indicating a fault on the MPI bus or loss of communication with a networked device.
    Check MPI cable connections and termination resistors. Verify bus address settings and ensure no address conflicts exist on the network.
    FRCE LED (Force Active)
    The yellow FRCE LED is illuminated, indicating that one or more I/O points are currently being forced via the programming device.
    Connect STEP 7 and disable all active force jobs under the PLC > Force menu to restore normal I/O operation.
    DC5V LED Off
    The internal 5 V DC supply is not present or has failed, causing the unit to be non-operational.
    Check the 24 V DC supply voltage at the input terminals. If supply is correct and LED remains off, the internal power supply may have failed and the unit requires repair or replacement.
    Configuration Error (HMI)
    The HMI component reports a configuration mismatch or cannot load the project downloaded via ProTool.
    Re-download the HMI project using ProTool with the correct target device selected. Verify that the project is compiled without errors before transfer.

    Frequently Asked Questions

    Is the SIMATIC C7-624 compatible with SIMATIC STEP 7 programming software?

    Yes, the C7-624 CPU is based on the S7-300 architecture and is programmed using SIMATIC STEP 7. The HMI portion is configured separately using ProTool software.

    What communication interface does the 6ES7624-1DE01-0AE3 support?

    The C7-624 supports MPI (Multi-Point Interface), which allows connection to SIMATIC S7 PLCs, programming devices (PGs), and other MPI-capable devices on the same network segment.

    What is the supply voltage for this unit?

    The C7-624 operates on a 24 V DC supply voltage, which must be connected to the designated power terminals on the rear of the unit.

    Can the C7-624 be used as a standalone controller without an external PLC?

    Yes, the C7-624 integrates both a CPU and an operator panel in one housing, allowing it to function as a standalone controller with onboard I/O for small to medium machine applications.

    What is the front panel protection rating of the C7-624?

    The front panel of the C7-624 carries an IP65 protection rating when correctly installed in a panel cutout with the supplied sealing gasket, making it suitable for environments with dust and water spray.

    Troubleshooting

    Display is blank after power is applied

    Check that 24 V DC is present at the power supply terminals using a multimeter. Verify that the supply polarity is correct and that the supply can deliver sufficient current.

    Correct any wiring errors or supply voltage issues. If the supply is confirmed correct and the display remains blank, the internal power supply or display backlight may have failed and the unit should be sent for repair.

    CPU remains in STOP mode and will not transition to RUN

    Connect a STEP 7 programming device via MPI and open the diagnostic buffer under Module Information to identify the specific fault preventing RUN mode.

    Resolve the identified fault, which may include correcting a program block error, resolving an I/O configuration mismatch, or performing a memory reset (MRES) followed by re-downloading the program.

    MPI communication cannot be established with a programming device

    Verify the MPI bus address of the C7-624 is correctly set and does not conflict with other devices. Check cable connections, termination resistors at both ends of the bus, and the baud rate setting on the programming device.

    Correct any address conflicts, ensure proper bus termination, and confirm the programming device MPI adapter baud rate matches the network. Replace the MPI cable if continuity testing reveals a fault.

    HMI screens display incorrectly or show configuration errors after project download

    Confirm that the ProTool project was compiled for the correct C7 target device type and that the transfer was completed without errors. Check available memory on the device.

    Recompile the ProTool project with the correct target device selected and re-download. If memory is insufficient, reduce the project size or perform a complete memory reset before downloading.

    Digital inputs or outputs are not responding as expected

    Use the STEP 7 variable monitor or force table to observe the actual state of I/O points. Check field wiring for correct connections, short circuits, or open circuits at the I/O terminals.

    Correct any wiring faults identified. If I/O points appear correct in software but do not respond physically, check for blown output protection or failed input circuitry, which may require unit repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart