Siemens 6AG1124-0GC01-4AX0 SIPLUS HMI TP700 Comfort
€ 883,00
The Siemens 6AG1124-0GC01-4AX0 is a member of the SIPLUS extreme product line, representing a ruggedized variant of the SIMATIC HMI TP700 Comfort panel. It belongs to the Comfort Panel series and is designed for human-machine interface applications requiring enhanced resistance to harsh environmental conditions, including extended temperature ranges and increased resistance to condensation and corrosive atmospheres. This panel provides a 7-inch widescreen TFT touch display for operator control and monitoring tasks in demanding industrial environments.
The panel features a 7-inch widescreen TFT display with a resolution of 800 x 480 pixels and 16 million colors, paired with a resistive single-touch screen. It is equipped with 12 MB of user memory for project data and supports a broad range of communication interfaces including PROFINET, Ethernet, MPI, PROFIBUS DP, USB (host and device), and an SD card slot for data storage and project transfer. The unit operates on a 24 V DC supply and runs on the Windows CE-based runtime environment, supporting WinCC Comfort/Advanced engineering software. The SIPLUS variant is conformal-coated and rated for operation in environments with increased levels of pollutants and humidity.
The 6AG1124-0GC01-4AX0 is deployed across industries such as chemical processing, water and wastewater treatment, food and beverage production, and offshore or marine environments where standard panels would be susceptible to corrosion or condensation damage. It is suitable for machine-level HMI tasks including process visualization, alarm management, recipe handling, and data logging. The ruggedized construction makes it particularly appropriate for control cabinets installed in areas with aggressive atmospheres or significant temperature fluctuations.
Technical Specifications
| Display Size | 7 inch widescreen |
|---|---|
| Display Resolution | 800 x 480 pixels |
| Display Colors | 16,777,216 (16 million) |
| Display Type | TFT |
| Touch Technology | Resistive single-touch |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 9 W |
| User Memory | 12 MB |
| Communication Interface | PROFINET, Ethernet (RJ45), MPI/PROFIBUS DP (RS 422/485), USB 2.0 (host and device), SD card slot |
| Operating Temperature | -20 °C to +60 °C |
| Storage Temperature | -40 °C to +70 °C |
| Relative Humidity | 5% to 95% (non-condensing, standard); conformal coating for condensing environments |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus, ATEX (Zone 2) |
| Series/Product Family | SIPLUS extreme / SIMATIC HMI Comfort Panel |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been interrupted.
Check PROFINET or PROFIBUS cabling and connector integrity. Verify PLC is powered and running. Confirm IP address or MPI/DP address settings match the project configuration. - Event ID: 20000
- Tag read/write error. The HMI is unable to read from or write to a configured PLC tag.
Verify the tag address exists in the PLC program and the data type matches the HMI configuration. Check communication connection status. - Event ID: 40000
- Project download error. Transfer of the HMI project from the engineering PC to the panel failed.
Ensure the panel is in Transfer mode. Verify the network or USB connection between the engineering PC and the panel. Check that WinCC project is compiled without errors before transfer. - Event ID: 70000
- Runtime system error. An internal fault has occurred within the HMI runtime environment.
Restart the HMI panel. If the fault persists, reload the project. Consider performing a factory reset and re-downloading the project if the issue continues. - Event ID: 50000
- Alarm logging error. The HMI is unable to write alarm or audit trail data to the configured storage medium.
Check that the SD card or USB storage device is correctly inserted and has sufficient free space. Verify the storage path configured in the project is valid. - Event ID: 30000
- Recipe data error. A recipe read or write operation could not be completed.
Check that the recipe storage medium is accessible and not write-protected. Verify recipe configuration in the WinCC project for correct data types and tag assignments. - Event ID: 60000
- System time synchronization error. The panel was unable to synchronize its clock with the configured time server or PLC.
Verify the time synchronization source is available and reachable. Check network connectivity and time server address settings in the project.
Frequently Asked Questions
What engineering software is required to program the 6AG1124-0GC01-4AX0?
This panel is configured using Siemens WinCC Comfort or WinCC Advanced, which is part of the TIA Portal engineering framework. TIA Portal V13 or later is recommended for full compatibility.
What is the difference between this SIPLUS variant and the standard SIMATIC TP700 Comfort?
The SIPLUS 6AG1124-0GC01-4AX0 is based on the standard SIMATIC HMI TP700 Comfort but features a conformal coating on the PCBs, an extended operating temperature range down to -20 °C, and enhanced resistance to condensation and corrosive gases, making it suitable for harsh industrial environments.
Which communication protocols does this panel support?
The panel supports PROFINET, Ethernet TCP/IP, MPI, PROFIBUS DP, and USB. It can communicate with Siemens S7-300, S7-400, S7-1200, and S7-1500 PLCs, as well as third-party controllers via OPC or other configured drivers.
Is the touch screen on this panel resistive or capacitive?
The 6AG1124-0GC01-4AX0 uses a resistive single-touch screen, which can be operated with gloves or a stylus, making it suitable for industrial environments where operators may wear protective equipment.
What is the IP protection rating of this panel?
The front of the panel is rated IP65, providing protection against dust and water jets. The rear of the panel is rated IP20 and must be installed inside a suitable enclosure.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for correct polarity. Verify the internal fuse if accessible.
Ensure the supply voltage is within the 24 V DC nominal range (typically 19.2 V to 28.8 V). Replace the power supply or cabling if voltage is absent or out of range. If voltage is correct and display remains blank, the panel may require repair or replacement of the backlight or power supply board.
HMI panel fails to establish communication with the PLC
Check the PROFINET or PROFIBUS DP cable connections at both the panel and PLC. Verify the IP address or bus address configured in the HMI project matches the actual PLC settings. Use the panel's diagnostic screen to view connection status.
Correct any address mismatches in the TIA Portal project and re-download. Replace faulty cables or connectors. Ensure the PLC is in RUN mode and the network switch or hub (if used) is functioning correctly.
Touchscreen does not respond or responds inaccurately
Check whether the screen responds at all or only in certain areas. Attempt a touchscreen calibration via the panel's Start Center or Control Panel. Inspect the screen surface for damage or contamination.
Clean the screen surface with a soft, dry cloth. Run the touchscreen calibration routine from the panel's operating system settings. If calibration does not resolve the issue, the touch overlay may be damaged and require replacement.
Project transfer from TIA Portal fails repeatedly
Verify the panel is set to Transfer mode (accessible from the Start Center). Check the Ethernet or USB connection between the engineering PC and the panel. Confirm there are no firewall rules blocking the transfer port.
Switch the panel to Transfer mode manually via the Start Center. Disable PC firewall temporarily to test. Use a direct Ethernet connection rather than a network switch. Ensure the TIA Portal project is fully compiled without errors before initiating the transfer.
Panel displays 'No project' or boots to Start Center unexpectedly
This typically indicates the project stored in the panel memory has been lost or corrupted, or the panel has been reset to factory defaults.
Re-download the HMI project from TIA Portal via Ethernet or USB. If the project file is unavailable, restore from a backup stored on an SD card. After download, verify all connections and tag communications are functioning correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page