• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AB12-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AB12-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AB12-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AB12-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a high-performance computing platform with a robust, fanless or fan-cooled enclosure suitable for direct panel integration.

    The SIMATIC Panel PC 670 (6AV7613-0AB12-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity and integration with Siemens SIMATIC WinCC or other SCADA/HMI software. The unit runs on a Windows-based operating system and is built to IEC 61131 and CE standards, with an IP65 protection rating on the front panel to resist dust and water ingress in industrial settings.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The combination of standard PC architecture with industrial-grade hardware makes it a practical choice for applications requiring custom HMI software or data logging capabilities.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet RJ45, USB, RS-232 (COM ports)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Embedded / Windows CE (variant dependent)

    Common Error Codes & System Events

    Event ID: 1000
    Application error – an HMI or SCADA application (e.g. WinCC) has encountered an unexpected fault and terminated.
    Check the Windows Event Viewer for detailed error logs. Reinstall or repair the HMI application. Verify that all required runtime licenses are present.
    Event ID: 6008
    Unexpected shutdown – the operating system was not shut down cleanly, indicating a possible power loss or system crash.
    Check the 24 V DC power supply for stability and correct voltage. Inspect UPS or power conditioning equipment. Review system logs for prior crash events.
    BIOS POST Error
    Hardware initialization failure during power-on self-test, which may indicate a RAM, CPU, or storage device fault.
    Reseat RAM modules and check all internal connectors. If the error persists, replace the defective hardware component or contact Siemens service.
    WinCC Runtime Error
    WinCC runtime cannot start due to a missing or corrupt project file, or an incompatible runtime version.
    Verify the WinCC project file integrity and ensure the installed runtime version matches the project version. Restore from backup if necessary.
    Network Connection Lost
    Ethernet communication to the PLC or SCADA server has been interrupted.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration and subnet settings. Test connectivity using ping from the Panel PC.
    Touchscreen Not Responding
    The resistive touch screen is not registering input, which may be caused by a calibration error or hardware fault.
    Recalibrate the touch screen via the Windows Control Panel or SIMATIC touch calibration utility. If unresponsive after calibration, inspect the touch controller connection or replace the touch overlay.
    Storage Device Error
    The internal CompactFlash card or hard disk is not detected or has read/write errors.
    Check the storage device seating and connector. Run a disk check utility. Replace the CompactFlash card or hard disk if errors persist, and restore the system image from backup.

    Frequently Asked Questions

    What is the display size and resolution of the 6AV7613-0AB12-0AE0?

    This Panel PC features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.

    What is the supply voltage for the SIMATIC Panel PC 670 (6AV7613-0AB12-0AE0)?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC products.

    What HMI software is compatible with this Panel PC?

    The 6AV7613-0AB12-0AE0 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based SCADA or HMI software packages, as it runs a Windows-based operating system.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets for use in industrial environments.

    Can this Panel PC communicate directly with Siemens S7 PLCs?

    Yes, via its Ethernet interface and appropriate communication drivers (e.g. S7 Ethernet driver in WinCC), the Panel PC can communicate directly with Siemens S7-300, S7-400, and S7-1500 series PLCs.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage and polarity. Check for any internal fuse on the power input board.

    Ensure the power supply is within the specified 24 V DC range and has sufficient current capacity. Replace any blown internal fuse with the correct rating. If the power supply board is faulty, replace it or return the unit for repair.

    Display is blank but the system appears to be running (LEDs active, HDD activity)

    Check the display backlight by shining a torch at the screen to see if a faint image is visible. Verify the display cable connection between the mainboard and the LCD panel.

    If a faint image is visible, the backlight inverter or CCFL backlight lamp has failed and should be replaced. If no image is visible at all, reseat the display cable or replace the LCD panel assembly.

    Touch screen input is inaccurate or offset from the actual touch position

    This is typically a touch screen calibration issue, particularly after a system image restore or OS reinstallation.

    Run the touch screen calibration utility from the Windows Control Panel or the SIMATIC calibration tool. Follow the on-screen prompts to recalibrate. If the problem persists, inspect the resistive touch overlay for physical damage and replace if necessary.

    System freezes or reboots randomly during operation

    Check the 24 V DC supply for voltage fluctuations or ripple using an oscilloscope. Monitor CPU and system temperatures via the BIOS or a system monitoring utility to check for overheating.

    Stabilize the power supply and add filtering if voltage fluctuations are detected. Clean any cooling vents or fans to improve airflow. If the system continues to freeze, run a memory diagnostic and consider replacing the RAM or the mainboard.

    Ethernet communication to PLC is intermittent or lost

    Check the Ethernet cable for damage and verify the connection at both the Panel PC and the network switch. Use the Windows network diagnostics or ping utility to test connectivity.

    Replace the Ethernet cable if damaged. Verify that the IP address, subnet mask, and gateway settings are correctly configured. Update the Ethernet adapter driver if necessary, and check for IP address conflicts on the network.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart