Siemens 6AV7613-0AB10-0CG0 Mobile Panel 170
€ 2.007,00
The Siemens 6AV7613-0AB10-0CG0 is a Mobile Panel 170, part of the SIMATIC HMI Mobile Panel family from Siemens. This handheld operator panel is designed for flexible, mobile operation and monitoring of machines and plant systems directly at the point of action. It provides a portable human-machine interface solution for applications where fixed panel installation is not practical or sufficient.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), offering clear visualization of process data and operator screens. It is equipped with a membrane keypad with configurable function keys, an integrated enabling button (dead man's switch) for safe operation in hazardous areas, and an emergency stop button. The unit connects to the control system via a coiled cable with an industrial connector, supporting MPI and PROFIBUS DP communication interfaces. It is configured using Siemens WinCC flexible engineering software.
The Mobile Panel 170 is widely used in the automotive, mechanical engineering, and process industries where operators need to move freely around a machine or production line during setup, commissioning, or maintenance tasks. Its integrated safety features, including the enabling button and emergency stop, make it suitable for use in safety-relevant applications on machinery subject to EN 60204-1 and related machine safety standards. The rugged housing and portable design make it well suited for demanding industrial shop floor environments.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Type | STN color LCD |
| Display Colors | 256 colors |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| IP/Protection Rating | IP65 (front) |
| Safety Features | Integrated enabling button (3-position), Emergency stop button |
| Connection Cable | Coiled connecting cable with industrial connector |
| Engineering Software | WinCC flexible |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected controller. The panel cannot establish or maintain a connection via MPI or PROFIBUS DP.
Check the connecting cable for damage or loose connections. Verify the MPI/PROFIBUS address settings on both the panel and the PLC. Ensure the bus termination resistors are correctly set. - Event ID: 10001
- Timeout on the communication link. The controller did not respond within the expected time window.
Check the cable connection and bus configuration. Verify the PLC is in RUN mode and the configured station address is correct. Reduce bus load if necessary. - Event ID: 20000
- Project download error. The configuration project could not be transferred to the Mobile Panel.
Verify the engineering PC is connected correctly and WinCC flexible is using the correct transfer settings. Check that the panel is in Transfer mode before initiating the download. - Event ID: 40000
- System memory low. The panel's available runtime memory is insufficient to execute the loaded project.
Reduce the complexity of the project, minimize the number of screens loaded simultaneously, or reduce image and font resources used in the project. - Enabling Button Fault
- The enabling button (3-position switch) has been released or is in an invalid state during an active enabling operation.
Ensure the operator is holding the enabling button in the middle (enabled) position. Inspect the enabling button mechanism for mechanical damage. If faulty, the panel must be repaired or replaced. - Emergency Stop Active
- The integrated emergency stop button on the Mobile Panel has been actuated, triggering a stop signal to the connected safety circuit.
Identify and resolve the cause of the emergency stop actuation. Unlock the emergency stop button by rotating it, then reset the safety circuit via the machine control system before resuming operation. - Event ID: 30000
- Operating system or firmware error detected on the panel during startup or runtime.
Perform a panel restart. If the error persists, reload the firmware using WinCC flexible ProSave tool and re-transfer the project to the panel.
Frequently Asked Questions
What communication interfaces does the Mobile Panel 170 (6AV7613-0AB10-0CG0) support?
The Mobile Panel 170 supports MPI and PROFIBUS DP communication interfaces, allowing it to connect directly to Siemens S7-300 and S7-400 PLCs as well as other PROFIBUS-compatible controllers.
What engineering software is required to configure this Mobile Panel?
The Mobile Panel 170 is configured using Siemens WinCC flexible. The project is transferred to the panel via the connecting cable using the Transfer function within WinCC flexible.
Does this Mobile Panel include safety features for use on machinery?
Yes, the 6AV7613-0AB10-0CG0 includes an integrated 3-position enabling button (dead man's switch) and a hardwired emergency stop button, making it suitable for safety-relevant machine operation in accordance with EN 60204-1.
What is the supply voltage for the Mobile Panel 170?
The Mobile Panel 170 operates on 24 V DC, which is typically supplied through the connecting cable from the machine control cabinet.
Is the Mobile Panel 170 compatible with S7-1200 or S7-1500 PLCs?
The Mobile Panel 170 uses MPI and PROFIBUS DP interfaces, which are not natively supported by S7-1200 or S7-1500 PLCs. It is primarily designed for use with S7-300 and S7-400 controllers.
Troubleshooting
Display remains blank after power on
Check that 24 V DC supply is present at the connecting cable connector. Measure voltage at the panel input. Inspect the cable for damage or broken conductors.
Ensure the power supply in the control cabinet is functioning and delivering 24 V DC. Replace the connecting cable if damaged. If power is confirmed but the display remains blank, the panel's internal power supply or display unit may require repair.
Panel cannot establish communication with the PLC
Verify the MPI or PROFIBUS DP address configured on the panel matches the network configuration. Check the cable connection and inspect for physical damage. Use a PROFIBUS diagnostic tool to check bus integrity.
Correct the station address settings in WinCC flexible and re-transfer the project. Ensure bus termination is correctly applied at both ends of the PROFIBUS segment. Replace the connecting cable if continuity tests fail.
Project transfer fails during download from WinCC flexible
Confirm the panel is set to Transfer mode (accessible via the Start Center on the panel). Check that the correct communication interface and transfer settings are selected in WinCC flexible on the engineering PC.
Switch the panel to Transfer mode manually via the Start Center menu. Select the correct COM port or MPI/PROFIBUS interface in WinCC flexible transfer settings. Retry the download. If it continues to fail, reload the panel firmware using ProSave.
Enabling button does not enable motion or the machine does not respond to enabling button input
Test the enabling button by checking the signal output at the safety relay or safety PLC input. Inspect the button mechanism for wear or mechanical failure. Verify the safety circuit wiring from the panel connector.
If the enabling button signal is not reaching the safety circuit, inspect and repair the wiring at the panel connector. If the button mechanism is worn or damaged, the Mobile Panel must be sent for repair or replacement, as the enabling button is a safety-critical component.
Touchscreen or keypad inputs are not responding correctly
Check whether the issue affects all keys or specific function keys. Inspect the membrane keypad surface for physical damage, contamination, or deformation. Verify the project configuration for correct key assignments.
Clean the keypad surface with a dry cloth. Re-transfer the project to rule out configuration errors. If specific keys are consistently unresponsive, the membrane keypad assembly may need replacement by a qualified repair technician.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page